Immersion & wet locations
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
Product
Heavy-Duty Submersible Mining Power Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (DIN VDE 0250 / IEC 60502-1, 1.8/3 kV (0.6/1 kV), -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard — confirmed in the datasheet and quotation for your order.
Application fit
Heavy-Duty Submersible Mining Power Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (DIN VDE 0250 / IEC 60502-1, 1.8/3 kV (0.6/1 kV), -40 to +90 °C, min. bend radius 6 × OD).
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
IEC 60228 Class 5 flexible copper conductors support suspended vertical riser drops in deep wells, sea cages and submersible pump shafts.
Installs cleanly along floating fish-farm walkways, mooring collars, hatchery basins and subsea pumping stations.
Withstands salt mist, ozone, UV exposure, fish oil and mechanical wave flexing in coastal and offshore aquaculture farms.
Submersible pump and aquaculture rubber cables are not intended for high-speed horizontal crane reeling drums.
Use RT-PUR-HF Reeling CableConstruction
Shown: Heavy Submersible Mining Power Cable (DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Single-Mode / Multi-Mode Optical Unit | Hermetic stainless-steel tube / tight-buffered optical unit |
| 2 | Power & Control Copper Conductors | Stranded copper conductors with High-modulus ethylene-propylene rubber (HEPR) insulation |
| 3 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard with single-mode / multi-mode optical unit and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Heavy Submersible Mining Power Cable Construction Schedule (−40…+90 °C) | |||||||
| Heavy Submersible Mining Power Cable Hybrid 4G2. | 4G2.5 mm² Power + 4×SM + 2×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 14.6 | 285 | 18.0 | 90 | |
| Heavy Submersible Mining Power Cable Hybrid 4G6+ | 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 19.2 | 540 | 32.0 | 120 | |
| Heavy Submersible Mining Power Cable Hybrid 4G16 | 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | Class 5 SnCu + Heavy Aramid + Subsea PUR | 26.5 | 1,120 | 55.0 | 165 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G2.5 mm² Power + 4×SM + 2×2×0.5 | 7.98 | 1.8/3 kV (0.6/1 kV) · 18 kN Tensile | −40…+90 °C |
| 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | 3.30 | 1.8/3 kV (0.6/1 kV) · 32 kN Tensile | −40…+90 °C |
| 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | 1.21 | 1.8/3 kV (0.6/1 kV) · 55 kN Tensile | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard) | Zero dielectric breakdown and verified wet insulation resistance for 1.8/3 kV (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (DIN VDE 0250 Heavy-Duty Submersible Mining & Dredging Power Cable Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.