Immersion & wet locations
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
Product
P7370-SP 1000V Heavy Duty XLPE Flat Submersible Cable featuring flexible stranded copper conductors (3 cores) and subsea / marine outer protective sheath (IEC 60502-1 / AS/NZS 5000, 1,000 V, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification — confirmed in the datasheet and quotation for your order.
Application fit
P7370-SP 1000V Heavy Duty XLPE Flat Submersible Cable featuring flexible stranded copper conductors (3 cores) and subsea / marine outer protective sheath (IEC 60502-1 / AS/NZS 5000, 1,000 V, -40 to +90 °C, min. bend radius 6 × OD).
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
IEC 60228 Class 5 flexible copper conductors support suspended vertical riser drops in deep wells, sea cages and submersible pump shafts.
Installs cleanly along floating fish-farm walkways, mooring collars, hatchery basins and subsea pumping stations.
Withstands salt mist, ozone, UV exposure, fish oil and mechanical wave flexing in coastal and offshore aquaculture farms.
Submersible pump and aquaculture rubber cables are not intended for high-speed horizontal crane reeling drums.
Use RT-PUR-HF Reeling CableConstruction
Shown: P7370-SP 1000V Flat XLPE (IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification) featuring flexible stranded copper conductors (3 cores), cross-linked polyethylene (xlpe) core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (3 C | IEC 60228 Class 5 finely stranded annealed copper phase conductors |
| 2 | Cross-Linked Polyethylene (XLPE) Core In | High-dielectric water-resistant thermoset XLPE insulation laid parallel |
| 3 | Water-Blocking Elastomeric Bedding Profi | Extruded flat moisture-barrier bedding locking parallel cores in place |
| 4 | Subsea / Marine Outer Protective Sheath | Heavy-duty abrasion- and hydrostatic-pressure-resistant flat outer jacket |
Built to IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification with flexible stranded copper conductors (3 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| P7370-SP 1000V Flat XLPE Construction Schedule (−40…+90 °C) | |||||||
| P7370-SP 1000V Flat XLPE 4G4.0 mm² | 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | IEC 60228 Class 5 Cu/SnCu | 14.2 | 340 | 3.2 | 85 | |
| P7370-SP 1000V Flat XLPE 4G16 mm² | 4G16 mm² (3×16 + 1G16 / 6 AWG) | IEC 60228 Class 5 Cu/SnCu | 21.4 | 840 | 9.6 | 130 | |
| P7370-SP 1000V Flat XLPE 3×50+1G25 mm² | 3 × 50 + 1G25 mm² (or 3×70+1G35) | IEC 60228 Class 5 Cu/SnCu | 32.8 | 2,240 | 26.5 | 195 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | 4.95 | 1,000 V (36 A Submersible) | −40…+90 °C |
| 4G16 mm² (3×16 + 1G16 / 6 AWG) | 1.21 | 1,000 V (98 A Submersible) | −40…+90 °C |
| 3 × 50 + 1G25 mm² (or 3×70+1G35) | 0.39 | 1,000 V (195 A Feeder) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification) | Zero dielectric breakdown and verified wet insulation resistance for 1,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60502-1 & AS/NZS 5000.1 Heavy-Duty XLPE Flat Submersible Pump Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.