Immersion & wet locations
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
Product
WRAS KTW Clean Water EPDM Submersible Pump Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (BS 6920 WRAS / KTW / EN 50525, 450/750 V (0.6/1 kV), -40 to +90 °C).
Typical values for this cable type, based on BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard — confirmed in the datasheet and quotation for your order.
Application fit
WRAS KTW Clean Water EPDM Submersible Pump Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (BS 6920 WRAS / KTW / EN 50525, 450/750 V (0.6/1 kV), -40 to +90 °C).
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
IEC 60228 Class 5 flexible copper conductors support suspended vertical riser drops in deep wells, sea cages and submersible pump shafts.
Installs cleanly along floating fish-farm walkways, mooring collars, hatchery basins and subsea pumping stations.
Withstands salt mist, ozone, UV exposure, fish oil and mechanical wave flexing in coastal and offshore aquaculture farms.
Submersible pump and aquaculture rubber cables are not intended for high-speed horizontal crane reeling drums.
Use RT-PUR-HF Reeling CableConstruction
Shown: WRAS/KTW EPDM Pump Cable (BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard) featuring flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (4 C | Class 5 / class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | Ethylene-propyiene rubber (epr/epdm) insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Blue clean-water non-toxic EPDM rubber outer sheath (AD8) |
Built to BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard with flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| WRAS/KTW EPDM Pump Cable Construction Schedule (−40…+90 °C) | |||||||
| WRAS 4G4.0 mm² | 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | IEC 60228 Class 5 Cu/SnCu | 14.2 | 340 | 3.2 | 85 | |
| WRAS 4G16 mm² | 4G16 mm² (3×16 + 1G16 / 6 AWG) | IEC 60228 Class 5 Cu/SnCu | 21.4 | 840 | 9.6 | 130 | |
| WRAS 3×50+1G25 mm² | 3 × 50 + 1G25 mm² (or 3×70+1G35) | IEC 60228 Class 5 Cu/SnCu | 32.8 | 2,240 | 26.5 | 195 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | 4.95 | 450/750 V (0.6/1 kV) (36 A Submersible) | −40…+90 °C |
| 4G16 mm² (3×16 + 1G16 / 6 AWG) | 1.21 | 450/750 V (0.6/1 kV) (98 A Submersible) | −40…+90 °C |
| 3 × 50 + 1G25 mm² (or 3×70+1G35) | 0.39 | 450/750 V (0.6/1 kV) (195 A Feeder) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard) | Zero dielectric breakdown and verified wet insulation resistance for 450/750 V (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (BS 6920 WRAS & KTW Approved EPDM Clean-Water Submersible Pump Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.