Contact
submersible aquaculture, pump & marine rubber cableIEC 60502-1 / NS 94150.6/1 kV (-40 to +90 °C)Subsea / Marine Outer Protective She

AQ-Line Power Flex Subsea Aquaculture Power CableIEC 60502-1 / NS 9415 — 0.6/1 kV — -40 to +90 °C Subsea & Marine Cable

AQ-Line Power Flex Subsea Aquaculture Power Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (IEC 60502-1 / NS 9415, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Water-resistant
Flame-retardant
Outdoor & humid
Approved
Order designation
AQ-Line Power Flex 0.6 4G4.0 mm²
Outer Ø ≈
14.2 mm
Net weight ≈
340 kg/km
Max. pulling ≈
3.2 kN
Core / stranding
IEC 60228 Class 5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60502-1 / NS 9415
Operating temp.
−40…+90 °C
Subsea, deck & cold-water duty
Min. bend radius
6 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Flexible Strande
Class 5/ class 6 copper conductors
Outer protection
Subsea / Marine
Black low-smoke zero-halogen (SHF1 / SHF
Standard
IEC 60502-1 / NS
IEC 60502-1 & NS 9415 AQ-Line Power Flex

Typical values for this cable type, based on IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is AQ-Line Power Flex 0.6/1kV right for your machine?

AQ-Line Power Flex Subsea Aquaculture Power Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (IEC 60502-1 / NS 9415, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.

Free-hanging vertical run

Suitable

IEC 60228 Class 5 flexible copper conductors support suspended vertical riser drops in deep wells, sea cages and submersible pump shafts.

Fixed installation

Suitable

Installs cleanly along floating fish-farm walkways, mooring collars, hatchery basins and subsea pumping stations.

Offshore platform & shipboard deck trays

Suitable

Withstands salt mist, ozone, UV exposure, fish oil and mechanical wave flexing in coastal and offshore aquaculture farms.

Motorised monospiral reel

Not suitable

Submersible pump and aquaculture rubber cables are not intended for high-speed horizontal crane reeling drums.

Use RT-PUR-HF Reeling Cable
Typical machinesUnderwater & Ocean ExplorationOffshore & Coastal Aquaculture Cage Power DistributionSubmersible Aerators, Blowers & Clean-Water Well PumpsWRAS / KTW Hatchery & Potable Water Pumping SystemsSubmersible Pool, Reservoir & Tank Cleaning Robots

Construction

Layer by layer

Shown: AQ-Line Power Flex 0.6/1kV (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification) featuring flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

AQ-Line Power Flex 0.6/1kV — stepped horizontal cutaway showing Flexible Stranded Copper Conductors (4 Cores) and Subs
Layer cutaway
#LayerMaterial & reference
1Flexible Stranded Copper Conductors (4 CClass 5/ class 6 copper conductors
2Cross-Linked Elastomeric / Polymer Core Cross-linked polyethylene (xlpe) insulation
3Water-Blocking Tape & Inner BeddingHydrostatic water-blocking filler and low-friction separator wrap
4Subsea / Marine Outer Protective SheathBlack low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath

AQ-Line Power Flex 0.6/1kV — Standard Subsea & Marine Execution

Built to IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification with flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath

AQ-Line Power Flex 0.6/1kV — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

AQ-Line Power Flex 0.6/1kV — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
0.6/1 kV (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification)
Core / conductor construction
Flexible Stranded Copper Conductors (4 Cores) — Class 5/ class 6 copper conductors
Primary dielectric / optical buffer
Cross-Linked Elastomeric / Polymer Core Insulation — Cross-linked polyethylene (xlpe) insulation

Thermal

Continuous operating temperature
−40…+90 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+90 °C per IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath
Minimum bending radius
6 × OD
Reinforcement / screen / bedding layer
Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
AQ-Line Power Flex 0.6/1kV
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard AQ-Line Power Flex 0.6/1kV configurations

Manufactured to IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
AQ-Line Power Flex 0.6/1kV Construction Schedule (−40…+90 °C)
AQ-Line Power Flex 0.6 4G4.0 mm²4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG)IEC 60228 Class 5 Cu/SnCu14.23403.285
AQ-Line Power Flex 0.6 4G16 mm²4G16 mm² (3×16 + 1G16 / 6 AWG)IEC 60228 Class 5 Cu/SnCu21.48409.6130
AQ-Line Power Flex 0.6 3×50+1G25 mm²3 × 50 + 1G25 mm² (or 3×70+1G35)IEC 60228 Class 5 Cu/SnCu32.82,24026.5195
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification)DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification)Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 / NS 9415 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX AQ-Line Power Flex 0.6/1kV IEC 60502-1 / NS 9415 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define AQ-Line Power Flex 0.6/1kV (AQ-Line Power Flex Subsea Aquaculture Power Cable)?
AQ-Line Power Flex 0.6/1kV (AQ-Line Power Flex Subsea Aquaculture Power Cable) is manufactured in accordance with IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification for 0.6/1 kV subsea,ROV and marine aquaculture service over -40 to +90 °C. Its 4-layer construction comprises flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for AQ-Line Power Flex 0.6/1kV?
The minimum bending radius for AQ-Line Power Flex 0.6/1kV is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of AQ-Line Power Flex 0.6/1kV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Flexible Stranded Copper Conductors (4 Cores) — Class 5/ class 6 copper conductors; (02) Cross-Linked Elastomeric / Polymer Core Insulation — Cross-linked polyethylene (xlpe) insulation; (03) Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap; (04) Subsea / Marine Outer Protective Sheath — Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath.
What factory test certificates are supplied with AQ-Line Power Flex 0.6/1kV?
Every production drum of AQ-Line Power Flex 0.6/1kV undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for AQ-Line Power Flex 0.6/1kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

AQ-Line Power Flex Subsea Aquaculture Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote