Immersion & wet locations
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
Product
AQ-Line Power Flex Subsea Aquaculture Power Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (IEC 60502-1 / NS 9415, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification — confirmed in the datasheet and quotation for your order.
Application fit
AQ-Line Power Flex Subsea Aquaculture Power Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (IEC 60502-1 / NS 9415, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Cross-linked EPDM, polychloroprene or subsea PUR elastomer compounds provide low water absorption and AD8 permanent immersion integrity.
IEC 60228 Class 5 flexible copper conductors support suspended vertical riser drops in deep wells, sea cages and submersible pump shafts.
Installs cleanly along floating fish-farm walkways, mooring collars, hatchery basins and subsea pumping stations.
Withstands salt mist, ozone, UV exposure, fish oil and mechanical wave flexing in coastal and offshore aquaculture farms.
Submersible pump and aquaculture rubber cables are not intended for high-speed horizontal crane reeling drums.
Use RT-PUR-HF Reeling CableConstruction
Shown: AQ-Line Power Flex 0.6/1kV (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification) featuring flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (4 C | Class 5/ class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | Cross-linked polyethylene (xlpe) insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath |
Built to IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification with flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| AQ-Line Power Flex 0.6/1kV Construction Schedule (−40…+90 °C) | |||||||
| AQ-Line Power Flex 0.6 4G4.0 mm² | 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | IEC 60228 Class 5 Cu/SnCu | 14.2 | 340 | 3.2 | 85 | |
| AQ-Line Power Flex 0.6 4G16 mm² | 4G16 mm² (3×16 + 1G16 / 6 AWG) | IEC 60228 Class 5 Cu/SnCu | 21.4 | 840 | 9.6 | 130 | |
| AQ-Line Power Flex 0.6 3×50+1G25 mm² | 3 × 50 + 1G25 mm² (or 3×70+1G35) | IEC 60228 Class 5 Cu/SnCu | 32.8 | 2,240 | 26.5 | 195 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | 4.95 | 0.6/1 kV (36 A Submersible) | −40…+90 °C |
| 4G16 mm² (3×16 + 1G16 / 6 AWG) | 1.21 | 0.6/1 kV (98 A Submersible) | −40…+90 °C |
| 3 × 50 + 1G25 mm² (or 3×70+1G35) | 0.39 | 0.6/1 kV (195 A Feeder) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification) | Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60502-1 & NS 9415 AQ-Line Power Flex Aquaculture Power Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.