Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
Subsea Ethernet (FM022208-01 to -14) & Subsea Cat 5e (FMXCAT51205K24 to FMXCAT52824K8) 10,000 PSI Deepwater Gigabit Ethernet & Power Hybrid ROV Umbilical Cable (TIA-568-B @ 10,000 PSI, 0.6/1 kV, -40 °C to +80 °C).
Typical values for this cable type, based on ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater — confirmed in the datasheet and quotation for your order.
Application fit
Subsea Ethernet (FM022208-01 to -14) & Subsea Cat 5e (FMXCAT51205K24 to FMXCAT52824K8) 10,000 PSI Deepwater Gigabit Ethernet & Power Hybrid ROV Umbilical Cable (TIA-568-B @ 10,000 PSI, 0.6/1 kV, -40 °C to +80 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: FM022208 (ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater) featuring 10,000 psi gigabit ethernet core, dual alum/braid emc shield and high-temp subsea pur jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 10,000 PSI Gigabit Ethernet Core | 4 pairs × 23/24 AWG pressure-stabilized data pairs (<2% deviation at 10,000 psi) |
| 2 | Dual Alum/Braid EMC Shield | 100% Aluminum/Polyester foil tape + high-coverage tinned copper braid shield |
| 3 | Power & Control Cores (4×18 AWG / 5×12 AWG) | Stranded tinned copper power/control conductors cabled around data core |
| 4 | Water-Block & Aramid Braid (K8–K24) | Elastomeric void water-blocking + Aramid strength braid (up to 2,400 lbs) |
| 5 | High-Temp Subsea PUR Jacket | Low-friction polyurethane jacket compatible with 120 °C hot-rubber molding |
Built to ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater with 10,000 psi gigabit ethernet core and high-temp subsea pur jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FM022208 Construction Schedule (−40…+80 °C) | |||||||
| FM022208 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| FM022208 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| FM022208 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −40…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −40…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater) | DC resistance at 20 °C / optical attenuation and outer diameter within ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ANSI/TIA-568-B Cat.5e/Cat.6 @ 10,000 PSI Deepwater) | Verified submersion integrity, tensile load and thermal stability across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.