Free-hanging vertical run
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Product
FDEFP 1.8/3 kV (0.6/1 kV) GB/T 29631 Tinned-Copper Braid Screened EPR/CR Wind Torsion Cable (GB/T 29631 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard — confirmed in the datasheet and quotation for your order.
Application fit
FDEFP 1.8/3 kV (0.6/1 kV) GB/T 29631 Tinned-Copper Braid Screened EPR/CR Wind Torsion Cable (GB/T 29631 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Routes continuously from nacelle generators and yaw/pitch cabinets through the free-hanging drip loop into upper tower trays.
Polychloroprene (CR/PCP), CPE, silicone (FDGG) and PUR (FDGU) sheaths resist hydraulic oil, grease, ozone, salt spray and −40 to −55 °C co
Copper-braid screened variants (FDEFP, FDEHP, WINDLINK WTTC) contain PWM converter electromagnetic interference along the drip loop.
Wind turbine vertical torsion rubber cable is optimized for axial twist rather than high-speed trolley festoons.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: FDEFP 1.8/3 kV Screened (GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard) featuring class 5 flexible copper / tinned copper cores, epr primary core insulation (code e) and polychloroprene (cr) / csm outer sheath (code f) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Flexible Copper / Tinned Copper | Stranded flexible copper conductors rated up to 1.8/3 kV |
| 2 | EPR Primary Core Insulation (Code E) | High-dielectric ethylene-propylene rubber insulation |
| 3 | Tinned Copper Wire Braid Screen (Code P) | High-coverage braided tinned copper EMC shield |
| 4 | Polychloroprene (CR) / CSM Outer Sheath | Oil-, salt-spray- and torsion-resistant heavy rubber jacket |
Built to GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard with class 5 flexible copper / tinned copper cores and polychloroprene (cr) / csm outer sheath (code f)
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FDEFP 1.8/3 kV Screened Construction Schedule (−40…+90 °C) | |||||||
| FDEFP 1.8 7G1.5 mm² | 7G1.5 mm² (or 7C × 16 AWG) | IEC 60228 Class 5/6 / Class K Cu | 11.4 | 215 | 2.4 | 70 | |
| FDEFP 1.8 12G1.5 mm² | 12G1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 5/6 / Class K Cu | 14.8 | 345 | 4.1 | 90 | |
| FDEFP 1.8 18G2.5 mm² | 18G2.5 mm² (or 18C × 14 AWG) | IEC 60228 Class 5/6 / Class K Cu | 19.6 | 680 | 9.8 | 120 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 7G1.5 mm² (or 7C × 16 AWG) | 13.30 | 1.8/3 kV (0.6/1 kV) (18 A) | −40…+90 °C |
| 12G1.5 mm² (or 12C × 16 AWG) | 13.30 | 1.8/3 kV (0.6/1 kV) (16 A) | −40…+90 °C |
| 18G2.5 mm² (or 18C × 14 AWG) | 7.98 | 1.8/3 kV (0.6/1 kV) (24 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard) | DC resistance at 20 °C and insulation/sheath wall thickness within GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (GB/T 29631 & NB/T 31034 FDEFP EMC-Screened EPR/CR Wind Torsion Cable Standard) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.