Free-hanging vertical run
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Product
FDEF 1.8/3 kV (0.6/1 kV) GB/T 29631 & NB/T 31034 EPR/CR Torsion-Resistant Wind Power Cable (GB/T 29631 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard — confirmed in the datasheet and quotation for your order.
Application fit
FDEF 1.8/3 kV (0.6/1 kV) GB/T 29631 & NB/T 31034 EPR/CR Torsion-Resistant Wind Power Cable (GB/T 29631 / NB/T 31034) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Routes continuously from nacelle generators and yaw/pitch cabinets through the free-hanging drip loop into upper tower trays.
Polychloroprene (CR/PCP), CPE, silicone (FDGG) and PUR (FDGU) sheaths resist hydraulic oil, grease, ozone, salt spray and −40 to −55 °C co
Copper-braid screened variants (FDEFP, FDEHP, WINDLINK WTTC) contain PWM converter electromagnetic interference along the drip loop.
Wind turbine vertical torsion rubber cable is optimized for axial twist rather than high-speed trolley festoons.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: FDEF 1.8/3 kV (GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard) featuring gb/t 3956 class 5 flexible copper conductors, epr / composite epr core insulation (code e) and polychloroprene (cr) / csm / cpe sheath (code f) (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | GB/T 3956 Class 5 Flexible Copper Conduc | Oxygen-free plain or tinned flexible copper (1C, 3-5C or 6-37C) |
| 2 | EPR / Composite EPR Core Insulation (Cod | High-dielectric ethylene-propylene rubber rated up to 1.8/3 kV |
| 3 | Polychloroprene (CR) / CSM / CPE Sheath | Cold- (-40 °C), oil- and torsion-resistant heavy rubber jacket |
Built to GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard with gb/t 3956 class 5 flexible copper conductors and polychloroprene (cr) / csm / cpe sheath (code f)
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FDEF 1.8/3 kV Construction Schedule (−40…+90 °C) | |||||||
| FDEF 1.8 1×95 / 4G25 Cu | 1 × 95 mm² (or 4G25 mm² / 3/0 AWG) | IEC 60228 Class 5 Flexible Cu/SnCu | 21.6 | 1,080 | 14.2 | 110 | |
| FDEF 1.8 1×185 / 4G50 Cu | 1 × 185 mm² (or 4G50 mm² / 373 kcmil) | IEC 60228 Class 5 Flexible Cu/SnCu | 27.8 | 1,960 | 27.5 | 140 | |
| FDEF 1.8 1×300 / 4G95 Cu | 1 × 300 mm² (or 1×535/777 kcmil) | IEC 60228 Class 5 Flexible Cu/SnCu | 34.6 | 3,120 | 45.0 | 175 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 95 mm² (or 4G25 mm² / 3/0 AWG) | 0.21 | 1.8/3 kV (0.6/1 kV) (320 A Cu) | −40…+90 °C |
| 1 × 185 mm² (or 4G50 mm² / 373 kcmil) | 0.11 | 1.8/3 kV (0.6/1 kV) (495 A Cu) | −40…+90 °C |
| 1 × 300 mm² (or 1×535/777 kcmil) | 0.06 | 1.8/3 kV (0.6/1 kV) (680 A Cu) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard) | DC resistance at 20 °C and insulation/sheath wall thickness within GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (GB/T 29631 & NB/T 31034 FDEF Torsion-Resistant Wind Turbine Cable Standard) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.