Contact
halogen-free wind turbine torsion & tower cableIEC 60502-1 / EN 503631.8/3 (3.6) kV (-40 to +90 °C)5GM5 HF-EVA LSZH Outer Sheath (±100°

EVA LSZH 1.8/3 (3.6) kV 3GI3 EPR / 5GM5 HF-EVA Torsion-Resistant Wind Turbine Power CableIEC 60502-1 / EN 50363 — 1.8/3 (3.6) kV — -40 to +90 °C Wind Turbine Cable

EVA LSZH 1.8/3 (3.6) kV 3GI3 EPR / 5GM5 HF-EVA Torsion-Resistant Wind Turbine Power Cable (IEC 60502-1 / EN 50363) engineered for 1.8/3 (3.6) kV wind turbine service across -40 to +90 °C (min. bend radius 5 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
EVA LSZH 1.8 1×95 / 4G25 Cu
Outer Ø ≈
21.6 mm
Net weight ≈
1,080 kg/km
Max. pulling ≈
14.2 kN
Core / stranding
IEC 60228 Class 5 Flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.8/3 (3.6) kV
Tested per IEC 60502-1 / EN 50363
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
5 × OD
Drip-loop, hub & tower routing
Core / conductor
EN 60228 Class 5
Flexible stranded plain copper conductor
Outer protection
5GM5 HF-EVA LSZH
Halogen-free flame-retardant EVA elastom
Standard
IEC 60502-1 / EN
IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 W

Typical values for this cable type, based on IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is EVA LSZH 1.8/3 kV Torsion right for your machine?

EVA LSZH 1.8/3 (3.6) kV 3GI3 EPR / 5GM5 HF-EVA Torsion-Resistant Wind Turbine Power Cable (IEC 60502-1 / EN 50363) engineered for 1.8/3 (3.6) kV wind turbine service across -40 to +90 °C (min. bend radius 5 × OD).

Free-hanging vertical run

Suitable

Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.

Fixed installation

Suitable

IEC 60332-3 flame-retardant low-smoke zero-halogen (LSZH) outer sheath routes safely through vertical wind tower ladders and cleats.

Offshore platform & shipboard deck trays

Suitable

Oil-, ozone-, UV- and salt-mist-resistant thermoset EVA/elastomer sheath endures both onshore and offshore wind nacelle environments.

Motor stator, traction & converter leads

Suitable

Finely stranded IEC 60228 Class 5 copper or AA8000 Al-alloy conductors terminate cleanly into generator, converter and transformer lugs.

Motorised monospiral reel

Not suitable

Wind turbine drip-loop torsion and fixed tower cables are not designed for high-speed horizontal crane reeling drums.

Use Spreader Reel Cable
Typical machinesRenewable Energy & EV ChargingOnshore & Offshore Wind Turbine Nacelle Drip LoopsWind Turbine Generator-to-Converter Main Power DropsHalogen-Free Wind Tower Vertical Power DistributionCold-Climate (−40 °C) Renewable Energy Installations

Construction

Layer by layer

Shown: EVA LSZH 1.8/3 kV Torsion (IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification) featuring en 60228 class 5 bare copper (25-400 mm²), 3gi3 ethylene-propylene rubber (epr) insulation and 5gm5 hf-eva lszh outer sheath (±100°/m) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1EN 60228 Class 5 Bare Copper (25-400 mm²Flexible stranded plain copper conductor for main power drop
23GI3 Ethylene-Propylene Rubber (EPR) Ins1.8/3 (3.6) kV cross-linked EPR primary dielectric
35GM5 HF-EVA LSZH Outer Sheath (±100°/m)Halogen-free flame-retardant EVA elastomer jacket (-40 °C to +90 °C)

EVA LSZH 1.8/3 kV Torsion — Standard Wind Turbine Execution

Built to IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification with en 60228 class 5 bare copper (25-400 mm²) and 5gm5 hf-eva lszh outer sheath (±100°/m)

EVA LSZH 1.8/3 kV Torsion — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

EVA LSZH 1.8/3 kV Torsion — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1.8/3 (3.6) kV (IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification)
Core / conductor construction
EN 60228 Class 5 Bare Copper (25-400 mm²) — Flexible stranded plain copper conductor for main power drop
Primary dielectric / insulation
3GI3 Ethylene-Propylene Rubber (EPR) Insulation — 1.8/3 (3.6) kV cross-linked EPR primary dielectric

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
5GM5 HF-EVA LSZH Outer Sheath (±100°/m) — Halogen-free flame-retardant EVA elastomer jacket (-40 °C to +90 °C)
Minimum bending radius
5 × OD
Intermediate screen / separator / core layer
3GI3 Ethylene-Propylene Rubber (EPR) Insulation — 1.8/3 (3.6) kV cross-linked EPR primary dielectric

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
EVA LSZH 1.8/3 kV Torsion
Sheath colour & metre marking
Continuous metre-marked black outer finish (5GM5 HF-EVA LSZH)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard EVA LSZH 1.8/3 kV Torsion wind turbine configurations

Manufactured to IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
EVA LSZH 1.8/3 kV Torsion Construction Schedule (−40…+90 °C)
EVA LSZH 1.8 1×95 / 4G25 Cu1 × 95 mm² (or 4G25 mm² / 3/0 AWG)IEC 60228 Class 5 Flexible Cu/SnCu21.61,08014.2110
EVA LSZH 1.8 1×185 / 4G50 Cu1 × 185 mm² (or 4G50 mm² / 373 kcmil)IEC 60228 Class 5 Flexible Cu/SnCu27.81,96027.5140
EVA LSZH 1.8 1×300 / 4G95 Cu1 × 300 mm² (or 1×535/777 kcmil)IEC 60228 Class 5 Flexible Cu/SnCu34.63,12045.0175
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification)DC resistance at 20 °C and insulation/sheath wall thickness within IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification)Zero dielectric breakdown and verified insulation resistance for 1.8/3 (3.6) kV ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 / EN 50363 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX EVA LSZH 1.8/3 kV Torsion IEC 60502-1 / EN 50363 1.8/3 (3.6) kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define EVA LSZH 1.8/3 kV Torsion (EVA LSZH 1.8/3 (3.6) kV 3GI3 EPR / 5GM5 HF-EVA Torsion-Resistant Wind Turbine Power Cable)?
EVA LSZH 1.8/3 kV Torsion (EVA LSZH 1.8/3 (3.6) kV 3GI3 EPR / 5GM5 HF-EVA Torsion-Resistant Wind Turbine Power Cable) is manufactured in accordance with IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification for 1.8/3 (3.6) kV wind turbine service over -40 to +90 °C. Its 3-layer construction comprises en 60228 class 5 bare copper (25-400 mm²), 3gi3 ethylene-propylene rubber (epr) insulation and 5gm5 hf-eva lszh outer sheath (±100°/m).
What is the minimum bending radius and operating temperature range for EVA LSZH 1.8/3 kV Torsion?
The minimum bending radius for EVA LSZH 1.8/3 kV Torsion is 5 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of EVA LSZH 1.8/3 kV Torsion arranged from inside to outside?
From inside to outside, the construction sequence is: (01) EN 60228 Class 5 Bare Copper (25-400 mm²) — Flexible stranded plain copper conductor for main power drop; (02) 3GI3 Ethylene-Propylene Rubber (EPR) Insulation — 1.8/3 (3.6) kV cross-linked EPR primary dielectric; (03) 5GM5 HF-EVA LSZH Outer Sheath (±100°/m) — Halogen-free flame-retardant EVA elastomer jacket (-40 °C to +90 °C).
What factory test certificates are supplied with EVA LSZH 1.8/3 kV Torsion?
Every production drum of EVA LSZH 1.8/3 kV Torsion undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per IEC 60502-1 & EN 50363-1/2-1 3GI3/5GM5 Wind Turbine Power Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for EVA LSZH 1.8/3 kV Torsion

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

EVA LSZH 1.8/3 (3.6) kV 3GI3 EPR / 5GM5 HF-EVA Torsion-Resistant Wind Turbine Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote