Contact
subsea umbilical, ROV tether & oceanographic tow cableUNOLS .322 EM Winch600 V (-40 to +85 °C)Double Contra-Helical Steel Armour

EQ05670 .322N (8.18 mm) 12,200 lbs Double-Armoured CTD Electromechanical Winch CableUNOLS .322 EM Winch — 600 V — -40 to +85 °C Subsea & Offshore Cable

EQ05670 .322N (8.18 mm) 12,200 lbs Double-Armoured CTD Electromechanical Winch Cable featuring tinned copper conductors (3 cores) and double contra-helical steel armour (UNOLS .322 EM Winch, 600 V, -40 to +85 °C).

Water-resistant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
EQ05670 .322N EM Type I
Outer Ø ≈
8.2 mm
Net weight ≈
265 kg/km
Tensile rating ≈
54.3 kN
Core / stranding
Stranded SnCu / Double Steel or UHMWPE
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per UNOLS .322 EM Winch
Operating temp.
−40…+85 °C
Continuous subsea & offshore service
Min. bend radius
15 × OD
Winch sheave, chute & seabed routing
Core / conductor
Tinned Copper Co
Three stranded tinned copper conductors
Outer protection
Double Contra-He
Torque-balanced galvanized steel wire ar
Standard
UNOLS .322 EM Wi
Hydrographic .322N (8.18 mm) 3-Conductor

Typical values for this cable type, based on Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is EQ05670 .322N EM right for your machine?

EQ05670 .322N (8.18 mm) 12,200 lbs Double-Armoured CTD Electromechanical Winch Cable featuring tinned copper conductors (3 cores) and double contra-helical steel armour (UNOLS .322 EM Winch, 600 V, -40 to +85 °C).

Immersion & wet locations

Suitable

Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.

Vertical / spreader reel

Suitable

Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling

Trailing & towing

Suitable

Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.

Offshore platform & shipboard deck trays

Suitable

UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.

Energy chain / drag chain

Not suitable

Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.

Use M23 Servo Assembly
Typical machinesUnderwater & Ocean ExplorationOceanographic CTD, ADCP & Deep-Tow SurveysWork-Class & Observation ROV / AUV SystemsSide-Scan Sonar, SAS & Towed Hydrophone ArraysMarine 2D/3D/UHR Seismic Streamers & OBC

Construction

Layer by layer

Shown: EQ05670 .322N EM (Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification) featuring tinned copper conductors (3 cores), polyolefin core insulation and double contra-helical steel armour (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Tinned Copper Conductors (3 Cores)Three stranded tinned copper conductors for CTD power & telemetry
2Polyolefin Core InsulationHigh-insulation-resistance polyolefin dielectric (Black, Red, White)
3Double Contra-Helical Steel ArmourTorque-balanced galvanized steel wire armour rated 12,200 lbs MBL

EQ05670 .322N EM — Standard Subsea & Offshore Execution

Built to Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification with tinned copper conductors (3 cores) and double contra-helical steel armour

EQ05670 .322N EM — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

EQ05670 .322N EM — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification)
Core / conductor construction
Tinned Copper Conductors (3 Cores) — Three stranded tinned copper conductors for CTD power & telemetry
Primary dielectric / buffering
Polyolefin Core Insulation — High-insulation-resistance polyolefin dielectric (Black, Red, White)

Thermal

Continuous operating temperature
−40…+85 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Double Contra-Helical Steel Armour — Torque-balanced galvanized steel wire armour rated 12,200 lbs MBL
Minimum bending radius
15 × OD
Armour, strength member & mechanical duty
Polyolefin Core Insulation — High-insulation-resistance polyolefin dielectric (Black, Red, White)

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
EQ05670 .322N EM
Sheath colour & metre marking
Continuous metre-marked black outer finish (Double Contra-He)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard EQ05670 .322N EM subsea & offshore configurations

Manufactured to Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
EQ05670 .322N EM Construction Schedule (−40…+85 °C)
EQ05670 .322N EM Type IStandard oceanographic / offshore buildStranded SnCu / Double Steel or UHMWPE8.226554.3125
EQ05670 .322N EM Type IIMedium-duty deepwater / offshore buildStranded SnCu / Double Steel or UHMWPE9.535564.9145
EQ05670 .322N EM Type IIIHeavy-duty deep-tow / offshore buildStranded SnCu / Double Steel or UHMWPE10.544079.2160
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification)DC resistance at 20 °C / optical attenuation and outer diameter within Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification)Zero dielectric breakdown and verified insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UNOLS .322 EM Winch CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX EQ05670 .322N EM UNOLS .322 EM Winch 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define EQ05670 .322N EM (EQ05670 .322N (8.18 mm) 12,200 lbs Double-Armoured CTD Electromechanical Winch Cable)?
EQ05670 .322N EM (EQ05670 .322N (8.18 mm) 12,200 lbs Double-Armoured CTD Electromechanical Winch Cable) is manufactured in accordance with Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification for 600 V service over -40 to +85 °C. Its 3-layer construction comprises tinned copper conductors (3 cores), polyolefin core insulation and double contra-helical steel armour.
What is the minimum bending radius and operating temperature range for EQ05670 .322N EM?
The minimum bending radius for EQ05670 .322N EM is 15 × OD across its continuous operating temperature range of -40 to +85 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of EQ05670 .322N EM arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Tinned Copper Conductors (3 Cores) — Three stranded tinned copper conductors for CTD power & telemetry; (02) Polyolefin Core Insulation — High-insulation-resistance polyolefin dielectric (Black, Red, White); (03) Double Contra-Helical Steel Armour — Torque-balanced galvanized steel wire armour rated 12,200 lbs MBL.
What factory test certificates are supplied with EQ05670 .322N EM?
Every production drum of EQ05670 .322N EM undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per Hydrographic .322N (8.18 mm) 3-Conductor Double-Armoured CTD Winch Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for EQ05670 .322N EM

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

EQ05670 .322N EM EQ05670 .322N (8.18 mm) 12,200 lbs Double-Armoured CTD Electromechanical Winch Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote