Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
Subsea EO (FM021814-1 to FM021814-10) 6,000m Deepwater 600V–4.0kV Electro-Optical Subsea Umbilical & Intervention Cable (ITU-T G.652.D / Subsea, 3.6/6 kV, -40 °C to +80 °C, min. bend radius 12 × OD).
Typical values for this cable type, based on ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard — confirmed in the datasheet and quotation for your order.
Application fit
Subsea EO (FM021814-1 to FM021814-10) 6,000m Deepwater 600V–4.0kV Electro-Optical Subsea Umbilical & Intervention Cable (ITU-T G.652.D / Subsea, 3.6/6 kV, -40 °C to +80 °C, min. bend radius 12 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: EO FM021814 (ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard) featuring hv power conductors (3×10 awg), subsea optical units (3×smf) and heavy-duty subsea pur jacket (ø16.64 mm) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | HV Power Conductors (3×10 AWG) | Stranded tinned copper with 3.6–4.0 kV low-water-absorption copolymer insulation |
| 2 | Subsea Optical Units (3×SMF) | Three PUR-jacketed 200 kpsi proof-tested OS2 9/125 µm single-mode fiber units |
| 3 | 6,000 m Water-Blocked Core | All interstices pressure-filled with thermoset elastomeric water-blocking compound |
| 4 | Synthetic Strength Braid (2,700–4,000 lb) | High-modulus aramid / LCP tensile braid (or optional GIPS steel armor) |
| 5 | Heavy-Duty Subsea PUR Jacket (Ø16.64 mm) | 0.090" (2.29 mm) cut- and hydrolysis-resistant black polyurethane jacket |
Built to ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard with hv power conductors (3×10 awg) and heavy-duty subsea pur jacket (ø16.64 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| EO FM021814 Construction Schedule (−40…+80 °C) | |||||||
| EO FM021814 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| EO FM021814 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| EO FM021814 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 3.6/6 kV (45–100 Ω data) | −40…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 3.6/6 kV (45–100 Ω data) | −40…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 3.6/6 kV (High-Power Hybrid) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard) | Zero dielectric breakdown and verified insulation resistance for 3.6/6 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ITU-T G.652.D / 6,000 m Deepwater EO Umbilical Standard) | Verified submersion integrity, tensile load and thermal stability across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.