Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
Wet-Mate DN 309076 6,400m Ultra-Deepwater Pressure-Balanced Oil-Filled (PBOF) Wet-Mateable Subsea Ethernet & 1000V Spec 44 Power Hybrid Flying Lead (7-Way & 12-Way EFL) (ISO/IEC 11801 / SPEC 44, 0.6/1 kV, -20 °C to +70 °C).
Typical values for this cable type, based on ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL — confirmed in the datasheet and quotation for your order.
Application fit
Wet-Mate DN 309076 6,400m Ultra-Deepwater Pressure-Balanced Oil-Filled (PBOF) Wet-Mateable Subsea Ethernet & 1000V Spec 44 Power Hybrid Flying Lead (7-Way & 12-Way EFL) (ISO/IEC 11801 / SPEC 44, 0.6/1 kV, -20 °C to +70 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: DN 309076 EFL (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL) featuring dual-barrier subsea ethernet core, 1,000 v spec 44 power wires (4×16 awg) and titanium wet-mate connector (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Dual-Barrier Subsea Ethernet Core | ISO/IEC 11801 Class D (100 m @ 100 MHz) shielded Ethernet with dual moisture barriers |
| 2 | 1,000 V Spec 44 Power Wires (4×16 AWG) | Twisted 16 AWG dual-wall irradiated Spec 44 power wires (620 VAC P-G, 3 A, ≥10 GΩ) |
| 3 | DC 200 Silicone Oil & PBOF Hose Conduit | High-purity DC 200 silicone fluid (6,400 m / 10,000 psi balanced) + MEG/acid-resistant PBOF hose |
| 4 | Titanium Wet-Mate Connector | 7-way or 12-way Titanium shell connector with oil-filled bladder & wiper boot (<500 N) |
Built to ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL with dual-barrier subsea ethernet core and titanium wet-mate connector
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| DN 309076 EFL Construction Schedule (−20…+70 °C) | |||||||
| DN 309076 EFL Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| DN 309076 EFL Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| DN 309076 EFL Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −20…+70 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −20…+70 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −20…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL) | DC resistance at 20 °C / optical attenuation and outer diameter within ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL) | Verified submersion integrity, tensile load and thermal stability across −20…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.