Contact
6,400 m PBOF subsea Ethernet & 1,000 V Spec 44 wet-mate EFLISO/IEC 11801 + SPEC 446,400 m PBOF Hybrid EFLTitanium Wet-Mate Plug

DN 309076 6,400m PBOF Subsea Ethernet & 1,000 V Spec 44 Flying LeadISO/IEC 11801 / SPEC 44 · 0.6/1 kV · 6,400 m pbof subsea ethernet & 1,000 v spec 44

Wet-Mate DN 309076 6,400m Ultra-Deepwater Pressure-Balanced Oil-Filled (PBOF) Wet-Mateable Subsea Ethernet & 1000V Spec 44 Power Hybrid Flying Lead (7-Way & 12-Way EFL) (ISO/IEC 11801 / SPEC 44, 0.6/1 kV, -20 °C to +70 °C).

Water-resistant
EMC screen
Low-EMC design
Approved
Order designation
DN 309076 EFL Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per ISO/IEC 11801 / SPEC 44
Operating temp.
−20…+70 °C
Continuous subsea & marine service
Min. bend radius
10 × OD
Dynamic sheave & fixed routing
Core / conductor
100Base-TX
Dual-barrier Class D Ethernet
Outer protection
PBOF Hose
PBOF hose filled + DC 200 fluid
Standard
ISO/IEC 11801
ISO/IEC 11801 Class D & SAE AS81044

Typical values for this cable type, based on ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL — confirmed in the datasheet and quotation for your order.

Application fit

Is DN 309076 EFL right for your machine?

Wet-Mate DN 309076 6,400m Ultra-Deepwater Pressure-Balanced Oil-Filled (PBOF) Wet-Mateable Subsea Ethernet & 1000V Spec 44 Power Hybrid Flying Lead (7-Way & 12-Way EFL) (ISO/IEC 11801 / SPEC 44, 0.6/1 kV, -20 °C to +70 °C).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: DN 309076 EFL (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL) featuring dual-barrier subsea ethernet core, 1,000 v spec 44 power wires (4×16 awg) and titanium wet-mate connector (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Dual-Barrier Subsea Ethernet CoreISO/IEC 11801 Class D (100 m @ 100 MHz) shielded Ethernet with dual moisture barriers
21,000 V Spec 44 Power Wires (4×16 AWG)Twisted 16 AWG dual-wall irradiated Spec 44 power wires (620 VAC P-G, 3 A, ≥10 GΩ)
3DC 200 Silicone Oil & PBOF Hose ConduitHigh-purity DC 200 silicone fluid (6,400 m / 10,000 psi balanced) + MEG/acid-resistant PBOF hose
4Titanium Wet-Mate Connector7-way or 12-way Titanium shell connector with oil-filled bladder & wiper boot (<500 N)

DN 309076 EFL — Standard Subsea & Marine Execution

Built to ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL with dual-barrier subsea ethernet core and titanium wet-mate connector

DN 309076 EFL — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

DN 309076 EFL — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL)
Core / conductor construction
Dual-Barrier Subsea Ethernet Core — ISO/IEC 11801 Class D (100 m @ 100 MHz) shielded Ethernet with dual moisture barriers
Primary dielectric / buffering
1,000 V Spec 44 Power Wires (4×16 AWG) — Twisted 16 AWG dual-wall irradiated Spec 44 power wires (620 VAC P-G, 3 A, ≥10 GΩ)

Thermal

Continuous operating temperature
−20…+70 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Titanium Wet-Mate Connector — 7-way or 12-way Titanium shell connector with oil-filled bladder & wiper boot (<500 N)
Minimum bending radius
10 × OD
Hydrostatic, tensile & crush duty
DC 200 Silicone Oil & PBOF Hose Conduit — High-purity DC 200 silicone fluid (6,400 m / 10,000 psi balanced) + MEG/acid-resistant PBOF hose

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
DN 309076 EFL
Sheath colour & metre marking
Continuous metre-marked yellow outer finish (PBOF Hose + Titanium Plug)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard DN 309076 EFL subsea & marine configurations

Manufactured to ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
DN 309076 EFL Construction Schedule (−20…+70 °C)
DN 309076 EFL Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
DN 309076 EFL Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
DN 309076 EFL Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL)DC resistance at 20 °C / optical attenuation and outer diameter within ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL)Verified submersion integrity, tensile load and thermal stability across −20…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ISO/IEC 11801 / SPEC 44 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX DN 309076 EFL ISO/IEC 11801 / SPEC 44 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define DN 309076 EFL (DN 309076 6,400m PBOF Subsea Ethernet & 1,000 V Spec 44 Flying Lead)?
DN 309076 EFL (DN 309076 6,400m PBOF Subsea Ethernet & 1,000 V Spec 44 Flying Lead) is manufactured in accordance with ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL for 0.6/1 kV service over -20 °C to +70 °C. Its 4-layer construction comprises dual-barrier subsea ethernet core, 1,000 v spec 44 power wires (4×16 awg) and titanium wet-mate connector.
What is the minimum bending radius and operating temperature range for DN 309076 EFL?
The minimum bending radius for DN 309076 EFL is 10 × OD across its continuous operating temperature range of -20 °C to +70 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of DN 309076 EFL arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Dual-Barrier Subsea Ethernet Core — ISO/IEC 11801 Class D (100 m @ 100 MHz) shielded Ethernet with dual moisture barriers; (02) 1,000 V Spec 44 Power Wires (4×16 AWG) — Twisted 16 AWG dual-wall irradiated Spec 44 power wires (620 VAC P-G, 3 A, ≥10 GΩ); (03) DC 200 Silicone Oil & PBOF Hose Conduit — High-purity DC 200 silicone fluid (6,400 m / 10,000 psi balanced) + MEG/acid-resistant PBOF hose; (04) Titanium Wet-Mate Connector — 7-way or 12-way Titanium shell connector with oil-filled bladder & wiper boot (<500 N).
What factory test certificates are supplied with DN 309076 EFL?
Every production drum of DN 309076 EFL undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ISO/IEC 11801 Class D & SAE AS81044 6,400 m PBOF EFL, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for DN 309076 EFL

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

DN 309076 EFL DN 309076 6,400m PBOF Subsea Ethernet & 1,000 V Spec 44 Flying Lead

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote