Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
A301241 (UNOLS 0.680" 3000 V 45-Ohm) Torque-Balanced Double-Armored Deep-Sea Coaxial & Multi-Coax Tow Cable (UNOLS 0.680" Coax, 1.8/3 kV, -40 °C to +80 °C, min. bend radius 15 × OD).
Typical values for this cable type, based on UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax — confirmed in the datasheet and quotation for your order.
Application fit
A301241 (UNOLS 0.680" 3000 V 45-Ohm) Torque-Balanced Double-Armored Deep-Sea Coaxial & Multi-Coax Tow Cable (UNOLS 0.680" Coax, 1.8/3 kV, -40 °C to +80 °C, min. bend radius 15 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: A301241 (UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax) featuring 0-6-12 center conductor, 3,000 v 45 ω hdpe dielectric and 22 + 36 sxgips torque-balanced armor (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 0-6-12 Center Conductor | Work-hardened half-hard copper wires stranded around central monofilament |
| 2 | 3,000 V 45 Ω HDPE Dielectric | Solid high-density polyethylene coaxial insulation rated for 3,000 VDC |
| 3 | Served Copper Return & Cu/PET Tape | Unidirectional served half-hard copper wires + copper-backed polyester tape |
| 4 | Polyallomer / HDPE Inner Belt | Tough extruded thermoplastic barrier isolating return conductor from armor |
| 5 | 22 + 36 SXGIPS Torque-Balanced Armor | Inner 22×1.65 mm + outer 36×1.27 mm 315 ksi galvanized steel wires (177.9 kN) |
Built to UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax with 0-6-12 center conductor and 22 + 36 sxgips torque-balanced armor
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| A301241 Construction Schedule (−40…+80 °C) | |||||||
| A301241 Type A (Standard Lift) | 3 × 10 mm² HV + 6×2×1.0 + 12F FIMT | Class 5 tinned Cu + 316L FIMT | 25.4 | 1,680 | 320.0 | 380 | |
| A301241 Type B (Heavy Work-Class) | 3 × 16 mm² HV + 8×2×1.0 + 12F FIMT | Class 5 tinned Cu + 316L FIMT | 32.2 | 2,650 | 480.0 | 485 | |
| A301241 Type C (Ultra-Deep Trencher) | 3 × 25 mm² HV + 12×2×1.0 + 24F FIMT | Class 5 tinned Cu + 316L FIMT | 38.1 | 3,890 | 680.0 | 570 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 10 mm² HV + 6×2×1.0 + 12F FIMT | 1.91 | 1.8/3 kV (≤0.35 dB/km SM) | −40…+80 °C |
| 3 × 16 mm² HV + 8×2×1.0 + 12F FIMT | 1.21 | 1.8/3 kV (≤0.35 dB/km SM) | −40…+80 °C |
| 3 × 25 mm² HV + 12×2×1.0 + 24F FIMT | 0.78 | 1.8/3 kV (≤0.35 dB/km SM) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax) | DC resistance at 20 °C / optical attenuation and outer diameter within UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (UNOLS Standard 0.680" (17.27 mm) 3,000 VDC Deep-Sea Coax) | Verified submersion integrity, tensile load and thermal stability across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.