Contact
subsea umbilical, ROV tether & oceanographic tow cableUNOLS / .414 EM Winch600 V (-40 to +85 °C)Double Contra-Helical Steel Armour

A216417 .414-Inch (10.52 mm) 17,800 lbs Double-Armoured Electromechanical Winch CableUNOLS / .414 EM Winch — 600 V — -40 to +85 °C Subsea & Offshore Cable

A216417 .414-Inch (10.52 mm) 17,800 lbs Double-Armoured Electromechanical Winch Cable featuring stranded copper conductors and double contra-helical steel armour (UNOLS / .414 EM Winch, 600 V, -40 to +85 °C, min. bend radius 15 × OD).

Water-resistant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
A216417 .414 EM Type I
Outer Ø ≈
8.2 mm
Net weight ≈
265 kg/km
Tensile rating ≈
54.3 kN
Core / stranding
Stranded SnCu / Double Steel or UHMWPE
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per UNOLS / .414 EM Winch
Operating temp.
−40…+85 °C
Continuous subsea & offshore service
Min. bend radius
15 × OD
Winch sheave, chute & seabed routing
Core / conductor
Stranded Copper
High-conductivity stranded copper electr
Outer protection
Double Contra-He
Two contra-helically served galvanized s
Standard
UNOLS / .414 EM
Hydrographic .414-Inch (10.52 mm) Torque

Typical values for this cable type, based on Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is A216417 .414 EM right for your machine?

A216417 .414-Inch (10.52 mm) 17,800 lbs Double-Armoured Electromechanical Winch Cable featuring stranded copper conductors and double contra-helical steel armour (UNOLS / .414 EM Winch, 600 V, -40 to +85 °C, min. bend radius 15 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.

Vertical / spreader reel

Suitable

Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling

Trailing & towing

Suitable

Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.

Offshore platform & shipboard deck trays

Suitable

UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.

Energy chain / drag chain

Not suitable

Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.

Use M23 Servo Assembly
Typical machinesUnderwater & Ocean ExplorationOceanographic CTD, ADCP & Deep-Tow SurveysWork-Class & Observation ROV / AUV SystemsSide-Scan Sonar, SAS & Towed Hydrophone ArraysMarine 2D/3D/UHR Seismic Streamers & OBC

Construction

Layer by layer

Shown: A216417 .414 EM (Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification) featuring stranded copper conductors, polyolefin core insulation and double contra-helical steel armour (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Copper ConductorsHigh-conductivity stranded copper electromechanical conductors
2Polyolefin Core InsulationLow-loss polyolefin dielectric color-coded Black, White, Red, Green
3Double Contra-Helical Steel ArmourTwo contra-helically served galvanized steel wire layers (Ø 10.52 mm, 17,800 lbs)

A216417 .414 EM — Standard Subsea & Offshore Execution

Built to Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification with stranded copper conductors and double contra-helical steel armour

A216417 .414 EM — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

A216417 .414 EM — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification)
Core / conductor construction
Stranded Copper Conductors — High-conductivity stranded copper electromechanical conductors
Primary dielectric / buffering
Polyolefin Core Insulation — Low-loss polyolefin dielectric color-coded Black, White, Red, Green

Thermal

Continuous operating temperature
−40…+85 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Double Contra-Helical Steel Armour — Two contra-helically served galvanized steel wire layers (Ø 10.52 mm, 17,800 lbs)
Minimum bending radius
15 × OD
Armour, strength member & mechanical duty
Polyolefin Core Insulation — Low-loss polyolefin dielectric color-coded Black, White, Red, Green

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
A216417 .414 EM
Sheath colour & metre marking
Continuous metre-marked black outer finish (Double Contra-He)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard A216417 .414 EM subsea & offshore configurations

Manufactured to Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
A216417 .414 EM Construction Schedule (−40…+85 °C)
A216417 .414 EM Type IStandard oceanographic / offshore buildStranded SnCu / Double Steel or UHMWPE8.226554.3125
A216417 .414 EM Type IIMedium-duty deepwater / offshore buildStranded SnCu / Double Steel or UHMWPE9.535564.9145
A216417 .414 EM Type IIIHeavy-duty deep-tow / offshore buildStranded SnCu / Double Steel or UHMWPE10.544079.2160
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification)DC resistance at 20 °C / optical attenuation and outer diameter within Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification)Zero dielectric breakdown and verified insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UNOLS / .414 EM Winch CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX A216417 .414 EM UNOLS / .414 EM Winch 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define A216417 .414 EM (A216417 .414-Inch (10.52 mm) 17,800 lbs Double-Armoured Electromechanical Winch Cable)?
A216417 .414 EM (A216417 .414-Inch (10.52 mm) 17,800 lbs Double-Armoured Electromechanical Winch Cable) is manufactured in accordance with Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification for 600 V service over -40 to +85 °C. Its 3-layer construction comprises stranded copper conductors, polyolefin core insulation and double contra-helical steel armour.
What is the minimum bending radius and operating temperature range for A216417 .414 EM?
The minimum bending radius for A216417 .414 EM is 15 × OD across its continuous operating temperature range of -40 to +85 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of A216417 .414 EM arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Copper Conductors — High-conductivity stranded copper electromechanical conductors; (02) Polyolefin Core Insulation — Low-loss polyolefin dielectric color-coded Black, White, Red, Green; (03) Double Contra-Helical Steel Armour — Two contra-helically served galvanized steel wire layers (Ø 10.52 mm, 17,800 lbs).
What factory test certificates are supplied with A216417 .414 EM?
Every production drum of A216417 .414 EM undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per Hydrographic .414-Inch (10.52 mm) Torque-Balanced Double-Armoured EM Winch Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for A216417 .414 EM

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

A216417 .414 EM A216417 .414-Inch (10.52 mm) 17,800 lbs Double-Armoured Electromechanical Winch Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp