Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-EN 60228 / ZN-CB / IEC 60332-1-2.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-EN 60228 / ZN-CB / IEC 60332-1-2 across -40 to +70 °C.
Typical values for this cable type, based on PN-EN 60228 / ZN-CB / IEC 60332-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-EN 60228 / ZN-CB / IEC 60332-1-2 across -40 to +70 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-EN 60228 / ZN-CB / IEC 60332-1-2.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 8 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +70 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: 8GTL3Gkon-G 300/500V (PN-EN 60228 / ZN-CB / IEC 60332-1-2) featuring central load-bearing cord, class 6 extra-flexible pairs (5×2×1.0) and heavy-duty 8g outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central Load-Bearing Cord | High-tensile central support cord absorbing mobile reeling/pulling forces |
| 2 | Class 6 Extra-Flexible Pairs (5×2×1.0) | PN-EN 60228 Class 6 tinned copper + EPR-based TPE (3G) insulation |
| 3 | Inner Elastomer Sheath | Polyester tape + natural-coloured thermoplastic elastomer inner sheath |
| 4 | Overall Tinned Copper Braid (kon) | High-density tinned copper wire braid shield (≥65% optical coverage) |
| 5 | Heavy-Duty 8G Outer Sheath | Black tear-resistant (300 N/cm², LOI 32%) polyolefin elastomer jacket |
Built to PN-EN 60228 / ZN-CB / IEC 60332-1-2 with central load-bearing cord and heavy-duty 8g outer sheath
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to PN-EN 60228 / ZN-CB / IEC 60332-1-2 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 8GTL3Gkon-G 300/500V Construction Schedule (-40 to +70 °C) | |||||||
| 8GTL3Gkon-G 3×2×1.0 mm² | 3 × 2 × 1.0 mm² | Class 6 tinned Cu | 16.2 | 345 | 2.4 | 130 | |
| 8GTL3Gkon-G 5×2×1.0 mm² | 5 × 2 × 1.0 mm² | Class 6 tinned Cu | 19.8 | 510 | 3.5 | 160 | |
| 8GTL3Gkon-G 7×2×1.0 mm² | 7 × 2 × 1.0 mm² | Class 6 tinned Cu | 22.4 | 665 | 4.2 | 180 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 2 × 1.0 mm² | 20.00 | 300/500 V (2.5 kV test) | -40 to +70 °C |
| 5 × 2 × 1.0 mm² | 20.00 | 300/500 V (2.5 kV test) | -40 to +70 °C |
| 7 × 2 × 1.0 mm² | 20.00 | 300/500 V (2.5 kV test) | -40 to +70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (PN-EN 60228 / ZN-CB / IEC 60332-1-2) | DC resistance at 20 °C / optical attenuation and outer diameter within PN-EN 60228 / ZN-CB / IEC 60332-1-2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (PN-EN 60228 / ZN-CB / IEC 60332-1-2) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (PN-EN 60228 / ZN-CB / IEC 60332-1-2) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.