Immersion & wet locations
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
Product
800 & 07 / 1 (Round & FL Flat Series) 450/750V & 0.6/1kV Deep-Well Potable Water Submersible Pump Cable (Up to 800m Depth) (WRAS / KTW / ACS, 0.6/1 kV, -25 °C to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174 — confirmed in the datasheet and quotation for your order.
Application fit
800 & 07 / 1 (Round & FL Flat Series) 450/750V & 0.6/1kV Deep-Well Potable Water Submersible Pump Cable (Up to 800m Depth) (WRAS / KTW / ACS, 0.6/1 kV, -25 °C to +80 °C, min. bend radius 6 × OD).
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.
Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.
Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.
Submersible rubber pump cable is not intended for high-acceleration automation drag chains.
Use Drag-Chain Control CableConstruction
Shown: 800 / 07 / 1 (DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174) featuring class 5 tinned copper conductors (4g16), high-modulus waterproof epr (ei7 / 3gi3) and quad-certified blue food-grade sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Tinned Copper Conductors (4G16) | IEC 60228 / VDE 0295 Class 5 flexible annealed tinned copper conductors |
| 2 | High-Modulus Waterproof EPR (EI7 / 3GI3) | 0.6/1 kV water-resistant EPR insulation color-coded Brown, Black, Grey & G/Y |
| 3 | Inner Waterproof Sheath Layer (800 m) | Extruded waterproof elastomeric inner bedding resisting 80 bar hydrostatic pressure |
| 4 | Quad-Certified Blue Food-Grade Sheath | Cross-linked 5GM3/EM2 elastomer certified to UK WRAS, ACS, KTW/W270 & DM 174/04 |
Built to DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174 with class 5 tinned copper conductors (4g16) and quad-certified blue food-grade sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174 for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 800 / 07 / 1 Construction Schedule (−25…+80 °C) | |||||||
| 800 4G16 mm² | 4G16 mm² (3×16 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 21.8 | 840 | 2.4 | 130 | |
| 800 4G35 mm² | 4G35 mm² (3×35 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 28.6 | 1,620 | 5.2 | 172 | |
| 800 3×70 + 3G16 mm² | 3 × 70 mm² + 3G16 mm² | IEC 60228 Class 5 flexible Cu/SnCu | 38.4 | 3,180 | 10.5 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (3×16 + 1G16) | 1.21 | 0.6/1 kV (94 A submerged) | −25…+80 °C |
| 4G35 mm² (3×35 + 1G16) | 0.55 | 0.6/1 kV (152 A submerged) | −25…+80 °C |
| 3 × 70 mm² + 3G16 mm² | 0.27 | 0.6/1 kV (235 A submerged) | −25…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0282 / UK WRAS / ACS / KTW-W270 / DM 174) | Verified submersion integrity, tensile load and thermal stability across −25…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.