Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
1SSA4 40-Ohm Heavy Double-Armoured Deep-Water Side-Scan & SAS Sonar Coaxial Tow Cable (71.2 kN) (1SSA4 / 40-Ohm Sonar Tow) engineered for 1,500 V DC service across -40 to +80 °C (min. bend radius 15 × OD).
Typical values for this cable type, based on 1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification — confirmed in the datasheet and quotation for your order.
Application fit
1SSA4 40-Ohm Heavy Double-Armoured Deep-Water Side-Scan & SAS Sonar Coaxial Tow Cable (71.2 kN) (1SSA4 / 40-Ohm Sonar Tow) engineered for 1,500 V DC service across -40 to +80 °C (min. bend radius 15 × OD).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: 1SSA4 40-Ohm (1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification) featuring high-conductivity copper center conductor, 40-ohm xlpe coaxial dielectric and 71.2 kn double preformed steel armour (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | High-Conductivity Copper Center Conducto | Stranded plain copper coaxial inner conductor |
| 2 | 40-Ohm XLPE Coaxial Dielectric | Cross-linked polyethylene insulation engineered for 40 O impedance |
| 3 | Copper Outer Coaxial Shield & XLPE Beddi | Helically served copper outer conductor + extruded XLPE inner sheath |
| 4 | 71.2 kN Double Preformed Steel Armour | Two contra-helical layers of high-tensile galvanized steel wire (2 11.5 mm) |
Built to 1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification with high-conductivity copper center conductor and 71.2 kn double preformed steel armour
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to 1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 1SSA4 40-Ohm Construction Schedule (−40…+80 °C) | |||||||
| 1SSA4 40-Ohm Coax / Cat5e | Coax (39/40/50/75 Ω) or 4Pr Cat5e + Power | Stranded SnCu + Foam PE/FEP + Armour/Aramid | 8.2 | 245 | 42.7 | 120 | |
| 1SSA4 40-Ohm Composite B | Heavy Coax / 64-Ch Digital Bus + Power | Stranded SnCu + Low-Loss Dielectric + Strength | 11.5 | 485 | 71.2 | 170 | |
| 1SSA4 40-Ohm Array / Trunk C | Multi-Ch Digital Streamer / 255-Ch Bus | Redundant Telemetry + Aramid + PUR Jacket | 44.5 | 1,620 | 95.0 | 445 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| Coax (39/40/50/75 Ω) or 4Pr Cat5e + Power | 18.50 | 1,500 V DC (High-Speed) | −40…+80 °C |
| Heavy Coax / 64-Ch Digital Bus + Power | 11.20 | 1,500 V DC (Deep-Tow/Array) | −40…+80 °C |
| Multi-Ch Digital Streamer / 255-Ch Bus | 6.80 | 1,500 V DC (Full Array) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within 1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification) | Zero dielectric breakdown and verified insulation resistance for 1,500 V DC rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (1SSA4 (Ø 11.5 mm, 71.2 kN MBL) 40-Ohm Heavy Armoured Coaxial Tow Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.