Motor stator, traction & converter leads
Engineered and verified for motor lead service in accordance with IEC 60317-35 / NEMA MW 131-C.
Product
Class 155 Solderable Polyurethane Self-Bonding Enamelled Copper Magnet Wire (MW 131-C / IEC 60317-35 PB155) engineered to IEC 60317-35 / NEMA MW 131-C for Up to 1000 V service across -40 °C to +155 °C, featuring stranded copper conductor and thermoplastic
Typical values for this cable type, based on IEC 60317-35 / NEMA MW 131-C — confirmed in the datasheet and quotation for your order.
Application fit
Class 155 Solderable Polyurethane Self-Bonding Enamelled Copper Magnet Wire (MW 131-C / IEC 60317-35 PB155) engineered to IEC 60317-35 / NEMA MW 131-C for Up to 1000 V service across -40 °C to +155 °C, featuring stranded copper conductor and thermoplastic
Engineered and verified for motor lead service in accordance with IEC 60317-35 / NEMA MW 131-C.
Engineered and verified for cabinet chassis service in accordance with IEC 60317-35 / NEMA MW 131-C.
Qualified for fixed installation on trays, racks, conduits or supports per IEC 60317-35 / NEMA MW 131-C.
Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.
Construction
Shown: MW 131-C / IEC 60317-35 PB155 (IEC 60317-35 / NEMA MW 131-C) with stranded copper conductor, polyurethane enamel base and thermoplastic butyral bonding film (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded copper conductor | High-conductivity copper conductor per IEC 60317-35 / NEMA MW 131-CIEC 60317-35 / NEMA MW 131-C |
| 2 | Polyurethane enamel base | Polyurethane enamel base (continuous layer)IEC 60317-35 / NEMA MW 131-C |
| 3 | Thermoplastic butyral bonding film | Extruded Thermoplastic butyral bonding film protective layer (continuous layer)IEC 60317-35 / NEMA MW 131-C |
Built to IEC 60317-35 / NEMA MW 131-C with stranded copper conductor and thermoplastic butyral bonding film
Full range of metric mm² and AWG/kcmil conductor sizes per IEC 60317-35 / NEMA MW 131-C
Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate
Technical data
Sizes
Precision drawn and insulated to IEC 60317-35 / NEMA MW 131-C in Grade 1 / Grade 2 builds and rectangular profiles.
| Order designation | Nominal conductor | Max. overall Ø mm | Weight ≈ kg/km | Min. mandrel R mm | Enquiry |
|---|---|---|---|---|---|
| MW 131-C / IEC 60317-35 PB155 Standard Precision Winding Schedule (−40…+155 °C) | |||||
| MW 131-C / IEC 60317-35 PB155 Ø 0.25 mm | Ø 0.25 mm (AWG 30) | 0.29 | 0.45 | 2 | |
| MW 131-C / IEC 60317-35 PB155 Ø 0.40 mm | Ø 0.40 mm (AWG 26) | 0.45 | 1.14 | 2 | |
| MW 131-C / IEC 60317-35 PB155 Ø 0.63 mm | Ø 0.63 mm (AWG 22) | 0.69 | 2.82 | 3 | |
| MW 131-C / IEC 60317-35 PB155 Ø 0.80 mm | Ø 0.80 mm (AWG 20) | 0.87 | 4.54 | 4 | |
| MW 131-C / IEC 60317-35 PB155 Ø 1.00 mm | Ø 1.00 mm (AWG 18) | 1.08 | 7.08 | 5 | |
| MW 131-C / IEC 60317-35 PB155 Ø 1.25 mm | Ø 1.25 mm (AWG 16) | 1.34 | 11.00 | 6 | |
| MW 131-C / IEC 60317-35 PB155 Ø 1.60 mm | Ø 1.60 mm (AWG 14) | 1.70 | 18.10 | 8 | |
| MW 131-C / IEC 60317-35 PB155 Ø 2.00 mm | Ø 2.00 mm (AWG 12) | 2.11 | 28.20 | 10 | |
| MW 131-C / IEC 60317-35 PB155 Ø 2.50 mm | Ø 2.50 mm (AWG 10) | 2.62 | 44.10 | 13 | |
| MW 131-C / IEC 60317-35 PB155 Ø 3.15 mm | Ø 3.15 mm (AWG 8) | 3.28 | 70.00 | 16 | |
| Conductor size | Nominal R₂₀ Ω/km | Min. breakdown V AC | Thermal class |
|---|---|---|---|
| Ø 0.25 mm (0.049 mm²) | 351.00 | 4,200 | −40…+155 °C |
| Ø 0.63 mm (0.312 mm²) | 55.30 | 5,000 | −40…+155 °C |
| Ø 1.00 mm (0.785 mm²) | 21.90 | 5,500 | −40…+155 °C |
| Ø 1.60 mm (2.011 mm²) | 8.57 | 5,800 | −40…+155 °C |
| Ø 2.50 mm (4.909 mm²) | 3.51 | 6,000 | −40…+155 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (IEC 60317-35 / NEMA MW 131-C) | DC resistance at 20 °C and geometry within IEC 60317-35 / NEMA MW 131-C class limits | Every manufactured drum / spool |
| Routine dielectric / spark / structural integrity test (IEC 60317-35 / NEMA MW 131-C) | Zero breakdown or structural defect over full production length | Every manufactured drum / spool |
| Sample tests | ||
| Thermal aging, mechanical & material qualification (IEC 60317-35 / NEMA MW 131-C) | Full compliance with IEC 60317-35 / NEMA MW 131-C across −40…+155 °C | Type qualification & periodic sample audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.