Crepe-Paper Insulated Flexible Stranded Copper Transformer Lead RopeIEC 60554-3 / IEC 60076 · Up to 220 kV · -40 °C to +105 °C industrial CREPE-PAPER COPPER ROPE

Crepe-Paper Insulated Flexible Stranded Copper Transformer Lead Rope engineered to IEC 60554-3 / IEC 60076 for Up to 220 kV service across -40 °C to +105 °C, featuring stranded copper conductor and crepe-paper tape insulation with minimum bending radius 5 × OD.

Approved
Oil-resistant
Flame-retardant
Order designation
CREPE-PAPER COPPER ROPE Ø 1.00 mm
Max. overall Ø
1.08 mm
Total weight ≈
7.08 kg/km
Min. mandrel R
5 mm
Nominal conductor
Ø 1.00 mm (AWG 18)
All sizes (10)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Up to 220 kV
Per IEC 60554-3 / IEC 60076
Operating temp.
−40…+105 °C
Continuous thermal rating
Min. bend radius
5 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
Crepe-paper
Crepe-paper tape insulation
Standard
IEC 60554-3
IEC 60554-3 / IEC 60076

Typical values for this cable type, based on IEC 60554-3 / IEC 60076 — confirmed in the datasheet and quotation for your order.

Application fit

Is Crepe-Paper Copper Rope right for your machine?

Crepe-Paper Insulated Flexible Stranded Copper Transformer Lead Rope engineered to IEC 60554-3 / IEC 60076 for Up to 220 kV service across -40 °C to +105 °C, featuring stranded copper conductor and crepe-paper tape insulation with minimum bending radius 5 × OD.

Motor stator, traction & converter leads

Suitable

Engineered and verified for motor lead service in accordance with IEC 60554-3 / IEC 60076.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with IEC 60554-3 / IEC 60076.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 5 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Typical machinesRenewable Energy & EV ChargingHigh-Voltage Grid & Substation InterconnectsWind, Solar & Hydro Power EvacuationUtility Overhead & Underground DistributionIndustrial Power Infrastructure

Construction

Layer by layer

Shown: CREPE-PAPER COPPER ROPE (IEC 60554-3 / IEC 60076) with stranded copper conductor, crepe-paper tape insulation and crepe-paper tape insulation (2-layer construction).

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per IEC 60554-3 / IEC 60076IEC 60554-3 / IEC 60076
2Crepe-paper tape insulationCrepe-paper tape insulation (lapped tape)IEC 60554-3 / IEC 60076

CREPE-PAPER COPPER ROPE — Standard Execution

Built to IEC 60554-3 / IEC 60076 with stranded copper conductor and crepe-paper tape insulation

CREPE-PAPER COPPER ROPE — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per IEC 60554-3 / IEC 60076

CREPE-PAPER COPPER ROPE — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60554-3 / IEC 60076. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
Up to 220 kV (IEC 60554-3 / IEC 60076)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per IEC 60554-3 / IEC 60076
Primary insulation / dielectric
Crepe-paper tape insulation — Crepe-paper tape insulation (lapped tape)

Thermal

Continuous operating temperature
−40…+105 °C per IEC 60554-3 / IEC 60076
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Crepe-paper tape insulation — Crepe-paper tape insulation (lapped tape)
Minimum bending radius
5 × OD (installed / static routing)
Layer count & geometry
2 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with IEC 60554-3 / IEC 60076
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
IEC 60554-3 / IEC 60076
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CREPE-PAPER COPPER ROPE
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

10 standard CREPE-PAPER COPPER ROPE winding & resistance wire dimensions

Precision drawn and insulated to IEC 60554-3 / IEC 60076 in Grade 1 / Grade 2 builds and rectangular profiles.

Nominal conductor diameter, overall Ø & weight
Order designationNominal conductorMax. overall Ø
mm
Weight ≈
kg/km
Min. mandrel R
mm
Enquiry
CREPE-PAPER COPPER ROPE Standard Precision Winding Schedule (−40…+105 °C)
CREPE-PAPER COPPER ROPE Ø 0.25 mmØ 0.25 mm (AWG 30)0.290.452
CREPE-PAPER COPPER ROPE Ø 0.40 mmØ 0.40 mm (AWG 26)0.451.142
CREPE-PAPER COPPER ROPE Ø 0.63 mmØ 0.63 mm (AWG 22)0.692.823
CREPE-PAPER COPPER ROPE Ø 0.80 mmØ 0.80 mm (AWG 20)0.874.544
CREPE-PAPER COPPER ROPE Ø 1.00 mmØ 1.00 mm (AWG 18)1.087.085
CREPE-PAPER COPPER ROPE Ø 1.25 mmØ 1.25 mm (AWG 16)1.3411.006
CREPE-PAPER COPPER ROPE Ø 1.60 mmØ 1.60 mm (AWG 14)1.7018.108
CREPE-PAPER COPPER ROPE Ø 2.00 mmØ 2.00 mm (AWG 12)2.1128.2010
CREPE-PAPER COPPER ROPE Ø 2.50 mmØ 2.50 mm (AWG 10)2.6244.1013
CREPE-PAPER COPPER ROPE Ø 3.15 mmØ 3.15 mm (AWG 8)3.2870.0016
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Supplied on precision PT25 / PT45 / PT90 / Din 355 conical and cylindrical winding spools per IEC 60554-3 / IEC 60076.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (IEC 60554-3 / IEC 60076)DC resistance at 20 °C and geometry within IEC 60554-3 / IEC 60076 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (IEC 60554-3 / IEC 60076)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (IEC 60554-3 / IEC 60076)Full compliance with IEC 60554-3 / IEC 60076 across −40…+105 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60554-3 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CREPE-PAPER COPPER ROPE <size> IEC 60554-3 Up to 220 kV CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CREPE-PAPER COPPER ROPE (Crepe-Paper Insulated Flexible Stranded Copper Transformer Lead Rope)?
CREPE-PAPER COPPER ROPE (Crepe-Paper Insulated Flexible Stranded Copper Transformer Lead Rope) is manufactured in accordance with IEC 60554-3 / IEC 60076 for Up to 220 kV service over -40 °C to +105 °C. Its 2-layer construction comprises stranded copper conductor, crepe-paper tape insulation.
What is the minimum bending radius and installation temperature for CREPE-PAPER COPPER ROPE?
The minimum installed bending radius for CREPE-PAPER COPPER ROPE is 5 × OD across its continuous operating temperature range of -40 °C to +105 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of CREPE-PAPER COPPER ROPE arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per IEC 60554-3 / IEC 60076); (02) Crepe-paper tape insulation (Crepe-paper tape insulation (lapped tape)).
What factory test certificates are supplied with CREPE-PAPER COPPER ROPE?
Every production drum or spool of CREPE-PAPER COPPER ROPE undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per IEC 60554-3 / IEC 60076, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Crepe-Paper Copper Rope

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Crepe-Paper Insulated Flexible Stranded Copper Transformer Lead Rope

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 