Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per ZN-TF-37 / WT-TK-21 / IEC 60332-3-24.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-TF-37 / WT-TK-21 / IEC 60332-3-24 across -30 to +70 °C.
Typical values for this cable type, based on ZN-TF-37 / WT-TK-21 / IEC 60332-3-24 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-TF-37 / WT-TK-21 / IEC 60332-3-24 across -30 to +70 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per ZN-TF-37 / WT-TK-21 / IEC 60332-3-24.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 10 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +70 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: YnTKGMFLY (ZN-TF-37 / WT-TK-21 / IEC 60332-3-24) featuring copper-steel bimetallic conductors (mfl), 5-pair pvc color coding (y) and mining flame-retardant sheath (yn) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Copper-Steel Bimetallic Conductors (MFL) | Composite multi-wire copper + high-tensile steel strands (0.5 mm² / Ø 0.8 mm) |
| 2 | 5-Pair PVC Color Coding (Y) | Pairs 1–5: Natural a-wire paired with Blue, Yellow, Green, Black & Red b-wire |
| 3 | Polyester Separator Tape | Helically lapped polyester film tape stabilizing the 5-pair core |
| 4 | Mining Flame-Retardant Sheath (Yn) | Grey high-LOI (LOI ≥ 29%) Cat. C flame-retardant PVC outer jacket |
Built to ZN-TF-37 / WT-TK-21 / IEC 60332-3-24 with copper-steel bimetallic conductors (mfl) and mining flame-retardant sheath (yn)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to ZN-TF-37 / WT-TK-21 / IEC 60332-3-24 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| YnTKGMFLY Construction Schedule (-30 to +70 °C) | |||||||
| YnTKGMFLY 2×2×0.8 (0.5 mm² MFL) | 2 × 2 × 0.5 mm² Cu/Fe Bimetallic | Composite Cu + Steel strands | 7.8 | 78 | 1.4 | 65 | |
| YnTKGMFLY 5×2×0.8 (0.5 mm² MFL) | 5 × 2 × 0.5 mm² Cu/Fe Bimetallic | Composite Cu + Steel strands | 11.2 | 152 | 3.2 | 90 | |
| YnTKGMFLY 10×2×0.8 (0.5 mm² MFL) | 10 × 2 × 0.5 mm² Cu/Fe Bimetallic | Composite Cu + Steel strands | 14.8 | 268 | 5.8 | 120 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.5 mm² Cu/Fe Bimetallic | 48.00 | ≤96 Ω/km loop · 1.4 kN tensile | -30 to +70 °C |
| 5 × 2 × 0.5 mm² Cu/Fe Bimetallic | 48.00 | ≤96 Ω/km loop · 3.2 kN tensile | -30 to +70 °C |
| 10 × 2 × 0.5 mm² Cu/Fe Bimetallic | 48.00 | ≤96 Ω/km loop · 5.8 kN tensile | -30 to +70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ZN-TF-37 / WT-TK-21 / IEC 60332-3-24) | DC resistance at 20 °C / optical attenuation and outer diameter within ZN-TF-37 / WT-TK-21 / IEC 60332-3-24 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ZN-TF-37 / WT-TK-21 / IEC 60332-3-24) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (ZN-TF-37 / WT-TK-21 / IEC 60332-3-24) | Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.