Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per IEC 60092-376 / IEC 60332-3-22 Cat A (XI(i) 150/250V IEC 60092-376) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableLow-smoke halogen-free 150/250 V XLPE/SHF1 construction protects confined shipboard switchrooms, accommodation decks, and bulkhead penetrations.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 4P×0.75 mm² Flexible Plain Cu |
| 2 | Insulation & Core Identification | XLPE insulation (0.75 mm² Flexible Cu, Black & Light-Blue) |
| 3 | Screen / Bedding / Armour Layer | Polyester binder tape |
| 4 | Outer Protective Sheath | Grey SHF1 halogen-free low-smoke outer sheath (IEC 60092-376) |
Class 5 Flexible Plain Copper · Outer diameter 11.5 mm
Class 5 Flexible Plain Copper · Outer diameter 13.6 mm
Class 5 Flexible Plain Copper · Outer diameter 15.9 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| XI(i) 150/250V IEC 60092-376 | |||||||||||
| 4P×0.75 mm² | Class 5 Flexible Plain Copper | XLPE insulation | LSZH Jacket | 11.5 | 115 | 24.13 | 161.7 | 311 | 4 A | XI(i) 150/250V IEC 60092-376 (4P×0.75 mm²) | |
| 8P×0.75 mm² | Class 5 Flexible Plain Copper | XLPE insulation | LSZH Jacket | 13.6 | 136 | 24.13 | 225.2 | 433 | 4 A | XI(i) 150/250V IEC 60092-376 (8P×0.75 mm²) | |
| 12P×0.75 mm² | Class 5 Flexible Plain Copper | XLPE insulation | LSZH Jacket | 15.9 | 159 | 24.13 | 307.8 | 592 | 4 A | XI(i) 150/250V IEC 60092-376 (12P×0.75 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.