XAI(c) 150/250V IEC 60092-376XAI(c) 150/250V IEC 60092-376 manufactured to IEC 60092-376 / IEC 60332-3-22 Cat A, rated 150/250 (300) V and -25°C to +90°C with a 10 × OD minimum bending radius for oil, gas & petrochemical installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
XAI(c) 150/250V IEC 60092-376 (4P×0.75 mm²)
Outer diameter
16.5 mm
Cable weight
640 kg/km
Min. bend radius
165 mm
Conductor & shield
Class 5 Flexible Plain Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
150/250 V
IEC 60092-376 / IEC 60332-3-22 Cat A
Temperature
-25°C to +90°C
Fixed / flex duty
Min. bend radius
10 × OD
16.5–22.8 mm
Screening
Foil + TC Braid
360° foil + tinned Cu braid
Outer sheath
LSZH Jacket
Halogen-free fire-safety corridors
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per IEC 60092-376 / IEC 60332-3-22 Cat A (XAI(c) 150/250V IEC 60092-376) — confirmed in the datasheet and quotation for your order.

Application fit

Is XAI(c) 150/250V IEC 60092-376 right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

TBM gantry & advancing tunnel reel

Suitable

Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Enclosed LSHF shipboard room

Suitable

Low-smoke halogen-free 150/250 V XLPE/SHF1 construction protects confined shipboard switchrooms, accommodation decks, and bulkhead penetrations.

Typical machinesMarine & Offshore CablePower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

XAI(c) 150/250V IEC 60092-376 – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor4P×0.75 mm² Flexible Plain Cu
2Insulation & Core IdentificationXLPE insulation (0.75 mm² Flexible Cu, Black & Light-Blue numbered)
3Screen / Bedding / Armour Layer100% Al/PE collective foil tape + tinned copper drain wire + Plain Copper Wire Braid Armour (XAI(c))
4Outer Protective SheathBlue SHF1 halogen-free low-smoke outer sheath (IEC 60092-376)

4P×0.75 mm²

Class 5 Flexible Plain Copper · Outer diameter 16.5 mm

8P×0.75 mm²

Class 5 Flexible Plain Copper · Outer diameter 19.5 mm

12P×0.75 mm²

Class 5 Flexible Plain Copper · Outer diameter 22.8 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per IEC 60092-376 / IEC 60332-3-22 Cat A (XAI(c) 150/250V IEC 60092-376). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
150/250 (300) V
Conductor & core insulation
4P×0.75 mm² Flexible Plain Cu · XLPE insulation (0.75 mm² Flexible Cu, Black & Light-Blue numbered)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-25°C to +90°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
IEC 60092-376 / IEC 60332-3-22 Cat A

Mechanical

Minimum bending radius
10 × OD
Screening / armour architecture
100% Al/PE collective foil tape + tinned copper drain wire + Plain Copper Wire Braid Armour (XAI(c))
Outer sheath material & colour
Blue SHF1 halogen-free low-smoke outer sheath (IEC 60092-376)

Reference standards

Reference standard
IEC 60092-376 / IEC 60332-3-22 Cat A
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
XAI(c) 150/250V IEC 60092-376
4P×0.75 mm²Class 5 Flexible Plain CopperXLPE insulationLSZH Jacket16.516524.13332.86404 AXAI(c) 150/250V IEC 60092-376 (4P×0.75 mm²)
8P×0.75 mm²Class 5 Flexible Plain CopperXLPE insulationLSZH Jacket19.519524.13463.38914 AXAI(c) 150/250V IEC 60092-376 (8P×0.75 mm²)
12P×0.75 mm²Class 5 Flexible Plain CopperXLPE insulationLSZH Jacket22.822824.13633.41,2184 AXAI(c) 150/250V IEC 60092-376 (12P×0.75 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60092-376 / IEC 60332-3-22 Cat A CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

XAI(C) 150/250V IEC 60092-376 / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is XAI(c) 150/250V IEC 60092-376 designed for?
XAI(c) 150/250V IEC 60092-376 is engineered for oil, gas & petrochemical installations under IEC 60092-376 / IEC 60332-3-22 Cat A, operating over -25°C to +90°C with a minimum bending radius of 10 × OD.
How is XAI(c) 150/250V IEC 60092-376 constructed across its layers?
Its 4-layer architecture combines 4P×0.75 mm² Flexible Plain Cu with XLPE insulation (0.75 mm² Flexible Cu, Black & Light-Blue numbered), 100% Al/PE collective foil tape + tinned copper drain wire + Plain Copper Wire Braid Armour (XAI(c)) and Blue SHF1 halogen-free low-smoke outer sheath (IEC 60092-376).
What standards and routine factory tests apply to XAI(c) 150/250V IEC 60092-376?
Every manufactured drum is tested to IEC 60092-376 / IEC 60332-3-22 Cat A for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for XAI(c) 150/250V IEC 60092-376?
Representative sizes include 4P×0.75 mm², 8P×0.75 mm² and 12P×0.75 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for XAI(c) 150/250V IEC 60092-376

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

XAI(c) 150/250V IEC 60092-376

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote