Contact
marine & offshore instrumentation cableVG 95218-64 / 95218-66150/250 V (-35 to +90 °C)Cross-Linked Naval LSZH Outer Sheath

VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) 250 V Superscreen Naval Combat System CableVG 95218-64 / 95218-66 — 150/250 V — -35 to +90 °C Marine & Offshore Cable

VG 95218-64 & VG 95218-66 (LFMGSGO / LFMGSSGO & LFMSGSSGO) 250 V Ultra-Thin-Wall Polyalkene Individually & Double Overall Copper-Braided Naval Combat System Switchboard Cable (VG 95218-64 / 95218-66, 150/250 V, -35 to +90 °C).

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
VG 95218-64 2×2×0.75 mm²
Outer Ø ≈
11.4 mm
Net weight ≈
195 kg/km
Tensile rating ≈
1.2 kN
Core / stranding
Stranded Cu/SnCu (IEC 60228 Class 2/5)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
150/250 V
Tested per VG 95218-64 / 95218-66
Operating temp.
−35…+90 °C
Continuous shipboard & offshore service
Min. bend radius
6 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Ultra-Thin Tinne
19-strand tinned copper with ultra-thin
Outer protection
Cross-Linked Nav
Halogen-free low-smoke low-toxicity wars
Standard
VG 95218-64 / 95
German Navy Standard VG 95218 Teil 64 (L

Typical values for this cable type, based on German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) — confirmed in the datasheet and quotation for your order.

Application fit

Is VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) right for your machine?

VG 95218-64 & VG 95218-66 (LFMGSGO / LFMGSSGO & LFMSGSSGO) 250 V Ultra-Thin-Wall Polyalkene Individually & Double Overall Copper-Braided Naval Combat System Switchboard Cable (VG 95218-64 / 95218-66, 150/250 V, -35 to +90 °C).

Fixed installation

Suitable

Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.

Offshore platform & shipboard deck trays

Suitable

SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.

Switchgear & control cabinet wiring

Suitable

Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.

Drilling jumbo & rotary mast feed

Suitable

Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.

Festoon & line chain

Not suitable

Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.

Use (N)3GRDC5G-J/O Festoon Cable
Typical machinesMarine & Offshore CableOffshore DCS, ESD & Fire-Gas SystemsShipboard Bridge & Engine Room AutomationDrilling Rig Instrumentation & Mud LoggingNaval Radar, Sonar & Combat Switchboards

Construction

Layer by layer

Shown: VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)) featuring ultra-thin tinned copper triads (7×3×0.35 mm²), individual tinned copper braid screen (teil 66) and cross-linked naval lszh outer sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Ultra-Thin Tinned Copper Triads (7×3×0.319-strand tinned copper with ultra-thin irradiated XLPO insulation
2Individual Tinned Copper Braid Screen (THigh-coverage tinned copper braid over each triad/pair unit
3Double Overall Tinned Copper Braid (SS)Two concentric overall tinned copper braids for maximum EMP/EMC attenuation
4Cross-Linked Naval LSZH Outer SheathHalogen-free low-smoke low-toxicity warship jacket

VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) — Standard Shipboard & Offshore Execution

Built to German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) with ultra-thin tinned copper triads (7×3×0.35 mm²) and cross-linked naval lszh outer sheath

VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO). Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
150/250 V (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO))
Core / conductor construction
Ultra-Thin Tinned Copper Triads (7×3×0.35 mm²) — 19-strand tinned copper with ultra-thin irradiated XLPO insulation
Primary dielectric / buffering
Individual Tinned Copper Braid Screen (Teil 66) — High-coverage tinned copper braid over each triad/pair unit

Thermal

Continuous operating temperature
−35…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Cross-Linked Naval LSZH Outer Sheath — Halogen-free low-smoke low-toxicity warship jacket
Minimum bending radius
6 × OD
Armour, screen & mechanical duty
Double Overall Tinned Copper Braid (SS) — Two concentric overall tinned copper braids for maximum EMP/EMC attenuation

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO)
Sheath colour & metre marking
Continuous metre-marked black outer finish (Cross-Linked Nav)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) shipboard & offshore configurations

Manufactured to German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) Construction Schedule (−35…+90 °C)
VG 95218-64 2×2×0.75 mm²2 × 2 × 0.75 mm² (2Pr)Stranded Cu/SnCu (IEC 60228 Class 2/5)11.41951.270
VG 95218-64 4×2×1.0 mm²4 × 2 × 1.0 mm² (4Pr)Stranded Cu/SnCu (IEC 60228 Class 2/5)15.63652.495
VG 95218-64 8×2×1.5 mm²8 × 2 × 1.5 mm² (8Pr)Stranded Cu/SnCu (IEC 60228 Class 2/5)22.87604.8140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO).

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO))DC resistance at 20 °C / optical attenuation and outer diameter within German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO))Zero dielectric breakdown and verified insulation resistance for 150/250 V ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO))Verified flame/fire performance, fluid resistance and thermal stability across −35…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VG 95218-64 / 95218-66 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) VG 95218-64 / 95218-66 150/250 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) (VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) 250 V Superscreen Naval Combat System Cable)?
VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) (VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) 250 V Superscreen Naval Combat System Cable) is manufactured in accordance with German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) for 150/250 V service over -35 to +90 °C. Its 4-layer construction comprises ultra-thin tinned copper triads (7×3×0.35 mm²), individual tinned copper braid screen (teil 66) and cross-linked naval lszh outer sheath.
What is the minimum bending radius and operating temperature range for VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO)?
The minimum bending radius for VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) is 6 × OD across its continuous operating temperature range of -35 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Ultra-Thin Tinned Copper Triads (7×3×0.35 mm²) — 19-strand tinned copper with ultra-thin irradiated XLPO insulation; (02) Individual Tinned Copper Braid Screen (Teil 66) — High-coverage tinned copper braid over each triad/pair unit; (03) Double Overall Tinned Copper Braid (SS) — Two concentric overall tinned copper braids for maximum EMP/EMC attenuation; (04) Cross-Linked Naval LSZH Outer Sheath — Halogen-free low-smoke low-toxicity warship jacket.
What factory test certificates are supplied with VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO)?
Every production drum of VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO), and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) 250 V Superscreen Naval Combat System Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote