Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
VG 95218-64 & VG 95218-66 (LFMGSGO / LFMGSSGO & LFMSGSSGO) 250 V Ultra-Thin-Wall Polyalkene Individually & Double Overall Copper-Braided Naval Combat System Switchboard Cable (VG 95218-64 / 95218-66, 150/250 V, -35 to +90 °C).
Typical values for this cable type, based on German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) — confirmed in the datasheet and quotation for your order.
Application fit
VG 95218-64 & VG 95218-66 (LFMGSGO / LFMGSSGO & LFMSGSSGO) 250 V Ultra-Thin-Wall Polyalkene Individually & Double Overall Copper-Braided Naval Combat System Switchboard Cable (VG 95218-64 / 95218-66, 150/250 V, -35 to +90 °C).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)) featuring ultra-thin tinned copper triads (7×3×0.35 mm²), individual tinned copper braid screen (teil 66) and cross-linked naval lszh outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Ultra-Thin Tinned Copper Triads (7×3×0.3 | 19-strand tinned copper with ultra-thin irradiated XLPO insulation |
| 2 | Individual Tinned Copper Braid Screen (T | High-coverage tinned copper braid over each triad/pair unit |
| 3 | Double Overall Tinned Copper Braid (SS) | Two concentric overall tinned copper braids for maximum EMP/EMC attenuation |
| 4 | Cross-Linked Naval LSZH Outer Sheath | Halogen-free low-smoke low-toxicity warship jacket |
Built to German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) with ultra-thin tinned copper triads (7×3×0.35 mm²) and cross-linked naval lszh outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| VG 95218-64 & VG 95218-66 (LFMGSSGO / LFMSGSSGO) Construction Schedule (−35…+90 °C) | |||||||
| VG 95218-64 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| VG 95218-64 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| VG 95218-64 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 150/250 V (≤60 nF/km) | −35…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 150/250 V (≤65 nF/km) | −35…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 150/250 V (≤75 nF/km) | −35…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)) | DC resistance at 20 °C / optical attenuation and outer diameter within German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO) tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (German Navy Standard VG 95218 Teil 64 (LFMGSSGO) & Teil 66 (LFMSGSSGO)) | Verified flame/fire performance, fluid resistance and thermal stability across −35…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.