Motor stator, traction & converter leads
Balanced 600/1000 V XLPE/PP geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.
Product
SERVO 7TCE 600/1000 V TC-ER bridges cable trays and moving servo axes without conduit, combining Class 5 bare copper phases, shielded brake pair, ≥ 85% tinned copper braid, and an orange oil-resistant jacket.
Typical values for this cable type, based on UL 1277 Type TC-ER · UL 2277 Type WTTC · CSA AWM I/II A/B FT4 — confirmed in the datasheet and quotation for your order.
Application fit
SERVO 7TCE 600/1000 V TC-ER bridges cable trays and moving servo axes without conduit, combining Class 5 bare copper phases, shielded brake pair, ≥ 85% tinned copper braid, and an orange oil-resistant jacket.
Balanced 600/1000 V XLPE/PP geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.
Durable 600/1000 V XLPE/PP outer sheath handles stationary routing along trays, machine beds, conduits, and plant racks.
Flexible oil-resistant 600/1000 V XLPE/PP construction routes cleanly along factory automation trays, machine frames, and production lines.
Screened 600/1000 V XLPE/PP construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.
600/1000 V XLPE/PP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR600/1000 V XLPE/PP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of SERVO 7TCE 600/1000V TC-ER: bare copper conductors, Low-capacitance thermoset XLPE / PP, Individually shielded brake pair + overall foil & ≥ 85% tinned Cu braid, and DESINA orange oil- & UV-resistant special PVC/TPE jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B8 Class B stranded bare annealed copperASTM B8 Class B / UL 44 |
| 2 | Core insulation | Low-capacitance thermoset XLPE / PPUL 1277 Type TC-ER |
| 3 | Core assembly & separator | Concentric cabled assembly with low-friction fleece or polyester binder tapeUL 1277 Type TC-ER |
| 4 | EMC metallic screen | Individually shielded brake pair + overall foil & ≥ 85% tinned Cu braidEMC ≥ 85% / 100% foil |
| 5 | Outer sheath | DESINA orange oil- & UV-resistant special PVC/TPE jacketUL Oil Res I/II |
Colour-coded or numbered phase conductors with protective green/yellow earth under overall EMC screening.
Technical data
Sizes
| Power + Brake AWG | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 4×14 AWG + 2×16 AWG | 14.6 | 8.450 | 145 | 324 | 117 |
| 4×12 AWG + 2×16 AWG | 15.8 | 5.310 | 194 | 411 | 126 |
| 4×10 AWG + 2×16 AWG | 17.3 | 3.340 | 270 | 540 | 138 |
| 4×8 AWG + 2×16 AWG | 21.0 | 2.100 | 395 | 792 | 168 |
| 4×6 AWG + 2×16 AWG | 23.4 | 1.320 | 583 | 1,102 | 187 |
| 4×4 AWG + 2×16 AWG | 27.2 | 0.832 | 884 | 1,612 | 218 |
| 4×2 AWG + 2×14 AWG | 32.2 | 0.523 | 1,368 | 2,425 | 258 |
| 4×1/0 AWG + 2×14 AWG | 36.9 | 0.329 | 2,111 | 3,587 | 295 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 4 kV AC for 5 min without breakdown | Every manufactured drum |
| Conductor DC resistance test | Per ASTM B172 / B8 at 20 °C | Every drum length |
| Sample tests | ||
| EMC screen coverage & insulation check | Foil + TCWB continuity & wall thickness | Per production lot |
| Flame & environmental qualification | UL Oil Res I/II · IEEE 1202 / FT4 Flame | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.