Contact
Servo, drag-chain & OCT hybrid cablesUL 1277 Type TC-ERU0/U 600/1000 V · 4 kV ACEMC Screened

SERIES SF 600/1000 V TPE Continuous-Flex Servo CableOrange TPE UL/CSA ultra-flex drag-chain servo motor & brake cable

SERIES SF 600/1000 V TPE Servo combines extra-flexible tinned copper stranding, low-capacitance polyolefin insulation, ≥ 85% tinned copper braid, and a rugged orange TPE jacket for high-cycle North American drag chains.

Low-EMC design
EMC screen
Flame-retardant
Oil-resistant
Order designation
SERIES SF 600/1000V TPE Servo 4×10 AWG + 2×16 AWG
Outer Ø
17.6 mm
Max. R20
3.590 Ω/km
Weight
548 kg/km
Min. bend R
132 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600/1000 V
AC test voltage 4 kV AC
EMC screening
≥ 85% TCWB
Low transfer impedance EMC shield
Temp. (fixed)
-40°C…+90°C
Flexing: -35 °C to +80 °C
Min. bend radius
7.5 × OD
Continuous drag-chain flexing
Conductor
Tinned Cu · Cl.K
ASTM B172 / B8 copper
Size range
14–1/0 AWG
8 standard configurations

Typical values for this cable type, based on UL 1277 Type TC-ER · UL 2277 Type WTTC · CSA AWM I/II A/B FT4 — confirmed in the datasheet and quotation for your order.

Application fit

Is SERIES SF 600/1000V TPE Servo right for your machine?

SERIES SF 600/1000 V TPE Servo combines extra-flexible tinned copper stranding, low-capacitance polyolefin insulation, ≥ 85% tinned copper braid, and a rugged orange TPE jacket for high-cycle North American drag chains.

Energy chain / drag chain

Suitable

Extra-flexible 600/1000 V XLPE/TPE stranding and 7.5×D bend rating endure continuous energy-chain flexing.

Motor stator, traction & converter leads

Suitable

Balanced 600/1000 V XLPE/TPE geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.

6-axis robot arm & torsion dress pack

Suitable

Multi-axis torsion-capable 600/1000 V XLPE/TPE stranding handles continuous robotic dress-pack twisting and automated assembly cells.

Factory automation tray & machine bus

Suitable

Flexible oil-resistant 600/1000 V XLPE/TPE construction routes cleanly along factory automation trays, machine frames, and production lines.

Motorised monospiral reel

Not suitable

600/1000 V XLPE/TPE build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.

Use RG / RG-D (N)SHTOEU-J

Immersion & wet locations

Not suitable

600/1000 V XLPE/TPE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial Automation CableAutomated assembly & handling linesCNC machine tools & gantry axesPackaging, robotics & intralogisticsFactory servo drive & motion bays

Construction

Layer by layer

Representative construction of SERIES SF 600/1000V TPE Servo: tinned copper conductors, Low-capacitance polyolefin / XLPE dielectric, Individually shielded brake pair + overall ≥ 85% tinned Cu braid, and DESINA orange abrasion- & coolant-resistant TPE jacket.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B172 Class K flexible tinned annealed copperASTM B172 Class K / UL 1277
2Core insulationLow-capacitance polyolefin / XLPE dielectricUL 1277 Type TC-ER
3Core assembly & separatorConcentric cabled assembly with low-friction fleece or polyester binder tapeUL 1277 Type TC-ER
4EMC metallic screenIndividually shielded brake pair + overall ≥ 85% tinned Cu braidEMC ≥ 85% / 100% foil
5Outer sheathDESINA orange abrasion- & coolant-resistant TPE jacketUL Oil Res I/II

SERIES SF 600/1000V TPE Servo Power & Ground

Colour-coded or numbered phase conductors with protective green/yellow earth under overall EMC screening.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 1277 Type TC-ER · UL 2277 Type WTTC · CSA AWM I/II A/B FT4. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
600/1000 V
AC test voltage
4 kV AC / 5 min
Conductor class
ASTM B172 Class K tinned Cu
EMC screen
Individually shielded brake pair +
Insulation resistance
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-40 °C to +90 °C
Temp. range (flexing)
-35 °C to +80 °C
Short-circuit temp.
+250 °C (5 s)
Min. bending radius
7.5 × OD (flexing)

Resistance

Flame retardance
UL Oil Res I/II
Oil & chemical perf.
10M+ Flex Cycles
Environmental / EMC
Sunlight Resistant
Outer sheath
DESINA orange abrasion- &

Sizes

4C Power + Shielded Brake Pair (AWG)
Power + Brake
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
7.5×D mm
4×14 AWG + 2×16 AWG14.89.070146329111
4×12 AWG + 2×16 AWG16.15.710195418121
4×10 AWG + 2×16 AWG17.63.590271548132
4×8 AWG + 2×16 AWG21.42.260397806160
4×6 AWG + 2×16 AWG23.91.4205851,120179
4×4 AWG + 2×16 AWG27.80.8928861,636208
4×2 AWG + 2×14 AWG33.00.5611,3702,461248
4×1/0 AWG + 2×14 AWG37.90.3532,1143,640284
  • Max. conductor DC resistance R20 at 20 °C per ASTM B172 / B8 (tinned copper).
  • Minimum bending radius calculated at 7.5 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage dielectric test4 kV AC for 5 min without breakdownEvery manufactured drum
Conductor DC resistance testPer ASTM B172 / B8 at 20 °CEvery drum length
Sample tests
EMC screen coverage & insulation check≥ 85% TCWB continuity & wall thicknessPer production lot
Flame & environmental qualificationUL Oil Res I/II · 10M+ Flex CyclesType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 1277 Type TC-ERUL 2277 Type WTTCCSA AWM I/II A/B FT4EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

SERIES SF 600/1000V TPE Servo 600/1000 V TEBAOFLEX.COM [UL 1277 Type TC-ER] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export reels
Standard drum lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-21
Updated
2026-11-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes SERIES SF 600/1000V TPE Servo suitable for 600/1000 V industrial installations?
SERIES SF 600/1000V TPE Servo combines tinned copper conductors, Low-capacitance polyolefin / XLPE dielectric, and Individually shielded brake pair + overall ≥ 85% tinned Cu braid inside a DESINA orange abrasion- & coolant-resistant TPE jacket. TPE outer jacket offers high cut-through strength and smooth glide inside multi-axis energy chains.
Can SERIES SF 600/1000V TPE Servo operate inside continuous drag chains or moving axes?
Yes. SERIES SF 600/1000V TPE Servo is built for continuous dynamic flexing with a minimum bending radius of 7.5 × OD across -35 °C to +80 °C operating temperatures.
How should the EMC shield of SERIES SF 600/1000V TPE Servo be grounded at termination?
Bond the metallic screen circumferentially (360°) at both drive and motor ends using EMC cable glands or low-impedance shielding clamps to minimize high-frequency transfer impedance.
What standards, drum lengths, and test certificates accompany SERIES SF 600/1000V TPE Servo?
SERIES SF 600/1000V TPE Servo conforms to UL 1277 Type TC-ER, UL 2277 Type WTTC, CSA AWM I/II A/B FT4 (UL Oil Res I/II) and ships cut-to-length or on export drums with an EN 10204 3.1 routine test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for SERIES SF 600/1000V TPE Servo

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SERIES SF 600/1000 V TPE Continuous-Flex Servo Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote