Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
Seal 428 500 V DC 300–570 kN Heavy Multi-Layer Steel-Armoured 3D Seismic Streamer Lead-In Cable (Seal 428 / 300–570 kN Lead-In) engineered for 500 V DC service across -30 to +80 °C (min. bend radius 15 × OD).
Typical values for this cable type, based on Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification — confirmed in the datasheet and quotation for your order.
Application fit
Seal 428 500 V DC 300–570 kN Heavy Multi-Layer Steel-Armoured 3D Seismic Streamer Lead-In Cable (Seal 428 / 300–570 kN Lead-In) engineered for 500 V DC service across -30 to +80 °C (min. bend radius 15 × OD).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: Seal 428 Lead-In (Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification) featuring high-speed single-mode optical unit, large-section copper power buses (6 cores) and 300–570 kn multi-layer steel wire armour (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | High-Speed Single-Mode Optical Unit | Central stainless-steel tube housing single-mode telemetry fibers |
| 2 | Large-Section Copper Power Buses (6 Core | Stranded copper conductors with XLPE/PE insulation feeding streamer array |
| 3 | Extruded Polymeric Inner Bedding | Void-free high-pressure polyethylene inner jacket |
| 4 | 300–570 kN Multi-Layer Steel Wire Armour | Contra-helical preformed heavy galvanized steel wire armour (1,500 m) |
Built to Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification with high-speed single-mode optical unit and 300–570 kn multi-layer steel wire armour
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Seal 428 Lead-In Construction Schedule (−30…+80 °C) | |||||||
| Seal 428 Lead-In 4–12F EOM/Sub | 4–12 × ITU-T G.652D / G.654E SM (+ Power) | Laser-welded SS FIMT + Steel/Aramid Armour | 8.2 | 260 | 48.0 | 125 | |
| Seal 428 Lead-In 24–48F EOM/Sub | 24–48 × ITU-T G.652D / G.654E SM (+ Power) | Laser-welded SS FIMT + Contra-Helical Steel | 17.5 | 680 | 120.0 | 260 | |
| Seal 428 Lead-In 96–192F Trunk | 96–192 × ITU-T G.654E / G.652D Submarine | SS Tube + Steel Vault + Cu Tube + DA Armour | 28.0 | 1,650 | 300.0 | 420 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4–12 × ITU-T G.652D / G.654E SM (+ Power) | 0.35 | ≤0.35 dB/km @ 1310 nm | −30…+80 °C |
| 24–48 × ITU-T G.652D / G.654E SM (+ Power) | 0.21 | ≤0.21 dB/km @ 1550 nm | −30…+80 °C |
| 96–192 × ITU-T G.654E / G.652D Submarine | 0.18 | ≤0.18 dB/km @ 1550 nm | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification) | Zero dielectric breakdown and verified insulation resistance for 500 V DC rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (Seal 428 (300/470/570 kN, 1,500 m) Heavy-Armoured Seismic Electro-Optical Lead-In Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.