wind turbine drip-loop, tray & pitch control cableDIN VDE 0285 / IEC 60502-1300/500 V – 0.6/1 kV (-50 to +90 °C)PUR / SCEM Cold-Resistant Jacket (-5

RT 114 / RT 116 300/500 V – 0.6/1 kV (UL 600 V) Class 6 PUR/SCEM Wind Torsion & Blade Trace-Heating CableDIN VDE 0285 / IEC 60502-1 — 300/500 V – 0.6/1 kV — -50 to +90 °C Wind Turbine Cable

RT 114 / RT 116 300/500 V – 0.6/1 kV (UL 600 V) Class 6 PUR/SCEM Wind Torsion & Blade Trace-Heating Cable (DIN VDE 0285 / IEC 60502-1) engineered for 300/500 V – 0.6/1 kV wind turbine service across -50 to +90 °C (min. bend radius 5 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
RT 114 7G1.5 mm²
Outer Ø ≈
11.4 mm
Net weight ≈
215 kg/km
Max. pulling ≈
2.4 kN
Core / stranding
IEC 60228 Class 5/6 / Class K Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V – 0.6/
Tested per DIN VDE 0285 / IEC 60502-1
Operating temp.
−50…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
5 × OD
Drip-loop, hub & tower routing
Core / conductor
Class 6 Extra-Fi
Ultra-flexible Class 6 copper conductors
Outer protection
PUR / SCEM Cold-
Oil- and abrasion-resistant outer sheath
Standard
DIN VDE 0285 / I
DIN VDE 0285 & UL 600 V RT 114 / RT 116

Typical values for this cable type, based on DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is RT 114 / RT 116 Torsion & De-Icing right for your machine?

RT 114 / RT 116 300/500 V – 0.6/1 kV (UL 600 V) Class 6 PUR/SCEM Wind Torsion & Blade Trace-Heating Cable (DIN VDE 0285 / IEC 60502-1) engineered for 300/500 V – 0.6/1 kV wind turbine service across -50 to +90 °C (min. bend radius 5 × OD).

Free-hanging vertical run

Suitable

Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−

Fixed installation

Suitable

UL 2277 WTTC 1,000 V / UL 1277 TC-ER 600 V and IEC 0.6/1 kV ratings allow open tray and Exposed Run routing across the nacelle and tower.

Switchgear & control cabinet wiring

Suitable

Number-coded cores and 85% tinned copper braid / foil+braid shields terminate neatly into pitch servo boxes, slip-rings and PLC cabinets.

Energy chain / drag chain

Suitable

PUR-sheathed Class 6 pitch & slip-ring cables (RT 113/123, RT 114/116) handle combined rotary hub motion and bending.

Vertical / spreader reel

Not suitable

Wind turbine control and tray cable is not engineered for deepwater vertical oceanographic lift winches.

Use A304739 BOP MUX Umbilical
Typical machinesRenewable Energy & EV ChargingWind Turbine Rotor Hub Pitch Control & Slip-RingsNacelle-to-Tower Multi-Core Drip-Loop Control BundlesUL 2277 WTTC / TC-ER Nacelle & Tower Cable TraysBlade De-Icing, Trace Heating & Aviation Obstruction Lights

Construction

Layer by layer

Shown: RT 114 / RT 116 Torsion & De-Icing (DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification) featuring class 6 extra-fine bare copper (2–40 cores), special tpe / cross-linked elastomer insulation and pur / scem cold-resistant jacket (-50 °c) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 6 Extra-Fine Bare Copper (2–40 CorUltra-flexible Class 6 copper conductors for continuous torsion
2Special TPE / Cross-Linked Elastomer InsRated 300/500 V, 600 V and 0.6/1 KV for control & trace heating
3PUR / SCEM Cold-Resistant Jacket (-50 °COil- and abrasion-resistant outer sheath rated ±150°/m torsion

RT 114 / RT 116 Torsion & De-Icing — Standard Wind Turbine Execution

Built to DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification with class 6 extra-fine bare copper (2–40 cores) and pur / scem cold-resistant jacket (-50 °c)

RT 114 / RT 116 Torsion & De-Icing — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

RT 114 / RT 116 Torsion & De-Icing — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
300/500 V – 0.6/1 kV (DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification)
Core / conductor construction
Class 6 Extra-Fine Bare Copper (2–40 Cores) — Ultra-flexible Class 6 copper conductors for continuous torsion
Primary dielectric / insulation
Special TPE / Cross-Linked Elastomer Insulation — Rated 300/500 V, 600 V and 0.6/1 KV for control & trace heating

Thermal

Continuous operating temperature
−50…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −50…+90 °C per DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
PUR / SCEM Cold-Resistant Jacket (-50 °C) — Oil- and abrasion-resistant outer sheath rated ±150°/m torsion
Minimum bending radius
5 × OD
Intermediate screen / separator / core layer
Special TPE / Cross-Linked Elastomer Insulation — Rated 300/500 V, 600 V and 0.6/1 KV for control & trace heating

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
RT 114 / RT 116 Torsion & De-Icing
Sheath colour & metre marking
Continuous metre-marked black outer finish (PUR / SCEM Cold-)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard RT 114 / RT 116 Torsion & De-Icing wind turbine configurations

Manufactured to DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
RT 114 / RT 116 Torsion & De-Icing Construction Schedule (−50…+90 °C)
RT 114 7G1.5 mm²7G1.5 mm² (or 7C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu11.42152.470
RT 114 12G1.5 mm²12G1.5 mm² (or 12C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu14.83454.190
RT 114 18G2.5 mm²18G2.5 mm² (or 18C × 14 AWG)IEC 60228 Class 5/6 / Class K Cu19.66809.8120
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification)DC resistance at 20 °C and insulation/sheath wall thickness within DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification)Zero dielectric breakdown and verified insulation resistance for 300/500 V – 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −50…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0285 / IEC 60502-1 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX RT 114 / RT 116 Torsion & De-Icing DIN VDE 0285 / IEC 60502-1 300/500 V – 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define RT 114 / RT 116 Torsion & De-Icing (RT 114 / RT 116 300/500 V – 0.6/1 kV (UL 600 V) Class 6 PUR/SCEM Wind Torsion & Blade Trace-Heating Cable)?
RT 114 / RT 116 Torsion & De-Icing (RT 114 / RT 116 300/500 V – 0.6/1 kV (UL 600 V) Class 6 PUR/SCEM Wind Torsion & Blade Trace-Heating Cable) is manufactured in accordance with DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification for 300/500 V – 0.6/1 kV wind turbine service over -50 to +90 °C. Its 3-layer construction comprises class 6 extra-fine bare copper (2–40 cores), special tpe / cross-linked elastomer insulation and pur / scem cold-resistant jacket (-50 °c).
What is the minimum bending radius and operating temperature range for RT 114 / RT 116 Torsion & De-Icing?
The minimum bending radius for RT 114 / RT 116 Torsion & De-Icing is 5 × OD across its continuous operating temperature range of -50 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of RT 114 / RT 116 Torsion & De-Icing arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 6 Extra-Fine Bare Copper (2–40 Cores) — Ultra-flexible Class 6 copper conductors for continuous torsion; (02) Special TPE / Cross-Linked Elastomer Insulation — Rated 300/500 V, 600 V and 0.6/1 KV for control & trace heating; (03) PUR / SCEM Cold-Resistant Jacket (-50 °C) — Oil- and abrasion-resistant outer sheath rated ±150°/m torsion.
What factory test certificates are supplied with RT 114 / RT 116 Torsion & De-Icing?
Every production drum of RT 114 / RT 116 Torsion & De-Icing undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per DIN VDE 0285 & UL 600 V RT 114 / RT 116 (-50 °C, ±150°/m) Wind Torsion & De-Icing Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for RT 114 / RT 116 Torsion & De-Icing

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

RT 114 / RT 116 Torsion & De-Icing RT 114 / RT 116 300/500 V – 0.6/1 kV (UL 600 V) Class 6 PUR/SCEM Wind Torsion & Blade Trace-Heating Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 