Fixed installation
Special halogen-free TPE jacket resists fish oil, organic fats, ozone, seawater splash and high-pressure hot-water chemical washdown.
Product
ROBUST ECOLAB IP69K Seafood Washdown Cable featuring flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath (EN 50525 / ECOLAB / IP69K, 300/500 V (0.6/1 kV), -40 to +90 °C, min. bend radius 4 × OD).
Typical values for this cable type, based on EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification — confirmed in the datasheet and quotation for your order.
Application fit
ROBUST ECOLAB IP69K Seafood Washdown Cable featuring flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath (EN 50525 / ECOLAB / IP69K, 300/500 V (0.6/1 kV), -40 to +90 °C, min. bend radius 4 × OD).
Special halogen-free TPE jacket resists fish oil, organic fats, ozone, seawater splash and high-pressure hot-water chemical washdown.
Finely stranded Class 5 copper conductors handle occasional flexing on suspended feeder booms, sorting lines and deck machinery.
UV-, weather- and cold-resistant down to −40/−50 °C for exposed aquaculture feed barges, coastal piers and workboats.
Compact outer diameter and optional tinned copper braid screen simplify termination into IP66/IP69K stainless control enclosures.
Unarmoured washdown control cable is not designed for high-tension deep-ocean winch deployment.
Use Type 5071/B Subsea CableConstruction
Shown: ROBUST ECOLAB IP69K Control (EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification) featuring flexible stranded copper conductors (5 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (5 C | Class 5 / class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | Thermoplastic elastomer (tpe) core insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification with flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| ROBUST ECOLAB IP69K Control Construction Schedule (−40…+90 °C) | |||||||
| ROBUST ECOLAB IP69K Control 4G1.5 / 5C18AWG | 4G1.5 mm² (or 5C × 18 AWG) | IEC 60228 Class 5/6 Cu/SnCu | 9.6 | 145 | 2.2 | 55 | |
| ROBUST ECOLAB IP69K Control 7G1.5 / 8C16AWG | 7G1.5 mm² (or 8C × 16 AWG) | IEC 60228 Class 5/6 Cu/SnCu | 12.2 | 235 | 3.6 | 70 | |
| ROBUST ECOLAB IP69K Control 12G2.5 / 16C16AWG | 12G2.5 mm² (or 16C × 16 AWG) | IEC 60228 Class 5/6 Cu/SnCu | 17.4 | 510 | 7.5 | 105 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G1.5 mm² (or 5C × 18 AWG) | 13.30 | 300/500 V (0.6/1 kV) (18 A) | −40…+90 °C |
| 7G1.5 mm² (or 8C × 16 AWG) | 13.30 | 300/500 V (0.6/1 kV) (16 A) | −40…+90 °C |
| 12G2.5 mm² (or 16C × 16 AWG) | 7.98 | 300/500 V (0.6/1 kV) (22 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification) | Zero dielectric breakdown and verified wet insulation resistance for 300/500 V (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (EN 50525 & ECOLAB IP69K Seafood Washdown Control Cable Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.