Contact
seawater- & washdown-resistant marine control cableEN 50525 / ECOLAB300/500 V (-50 to +80 °C)Subsea / Marine Outer Protective She

ROBUST 210 Chemical & Bio-Oil Control CableEN 50525 / ECOLAB — 300/500 V — -50 to +80 °C Subsea & Marine Cable

ROBUST 210 Chemical & Bio-Oil Control Cable featuring flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath (EN 50525 / ECOLAB, 300/500 V, -50 to +80 °C, min. bend radius 4 × OD).

Water-resistant
Flame-retardant
Outdoor & humid
Approved
Order designation
ROBUST 210 300 4G1.5 / 5C18AWG
Outer Ø ≈
9.6 mm
Net weight ≈
145 kg/km
Max. pulling ≈
2.2 kN
Core / stranding
IEC 60228 Class 5/6 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Tested per EN 50525 / ECOLAB
Operating temp.
−50…+80 °C
Subsea, deck & cold-water duty
Min. bend radius
4 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Flexible Strande
Class 5 / class 6 copper conductors
Outer protection
Subsea / Marine
Black low-smoke zero-halogen (SHF1 / SHF
Standard
EN 50525 / ECOLA
EN 50525 & ECOLAB Chemical & Bio-Oil Res

Typical values for this cable type, based on EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is ROBUST 210 300/500V right for your machine?

ROBUST 210 Chemical & Bio-Oil Control Cable featuring flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath (EN 50525 / ECOLAB, 300/500 V, -50 to +80 °C, min. bend radius 4 × OD).

Fixed installation

Suitable

Special halogen-free TPE jacket resists fish oil, organic fats, ozone, seawater splash and high-pressure hot-water chemical washdown.

Free-hanging vertical run

Suitable

Finely stranded Class 5 copper conductors handle occasional flexing on suspended feeder booms, sorting lines and deck machinery.

Offshore platform & shipboard deck trays

Suitable

UV-, weather- and cold-resistant down to −40/−50 °C for exposed aquaculture feed barges, coastal piers and workboats.

Switchgear & control cabinet wiring

Suitable

Compact outer diameter and optional tinned copper braid screen simplify termination into IP66/IP69K stainless control enclosures.

Vertical / spreader reel

Not suitable

Unarmoured washdown control cable is not designed for high-tension deep-ocean winch deployment.

Use Type 5071/B Subsea Cable
Typical machinesUnderwater & Ocean ExplorationSeafood Processing & Packaging IP69K Washdown LinesOffshore Aquaculture Feed Barges & Sorting MachineryRecirculating Aquaculture (RAS) Valve & Dosing ControlCoastal Marine Deck Equipment & Workboat Control Panels

Construction

Layer by layer

Shown: ROBUST 210 300/500V (EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification) featuring flexible stranded copper conductors (5 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

ROBUST 210 300/500V — stepped horizontal cutaway showing Flexible Stranded Copper Conductors (5 Cores) and Subsea / Ma
Layer cutaway
#LayerMaterial & reference
1Flexible Stranded Copper Conductors (5 CClass 5 / class 6 copper conductors
2Cross-Linked Elastomeric / Polymer Core Thermoplastic elastomer (tpe) core insulation
3Water-Blocking Tape & Inner BeddingHydrostatic water-blocking filler and low-friction separator wrap
4Subsea / Marine Outer Protective SheathBlack low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath

ROBUST 210 300/500V — Standard Subsea & Marine Execution

Built to EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification with flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath

ROBUST 210 300/500V — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

ROBUST 210 300/500V — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
300/500 V (EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification)
Core / conductor construction
Flexible Stranded Copper Conductors (5 Cores) — Class 5 / class 6 copper conductors
Primary dielectric / optical buffer
Cross-Linked Elastomeric / Polymer Core Insulation — Thermoplastic elastomer (tpe) core insulation

Thermal

Continuous operating temperature
−50…+80 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −50…+80 °C per EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath
Minimum bending radius
4 × OD
Reinforcement / screen / bedding layer
Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
ROBUST 210 300/500V
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard ROBUST 210 300/500V configurations

Manufactured to EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
ROBUST 210 300/500V Construction Schedule (−50…+80 °C)
ROBUST 210 300 4G1.5 / 5C18AWG4G1.5 mm² (or 5C × 18 AWG)IEC 60228 Class 5/6 Cu/SnCu9.61452.255
ROBUST 210 300 7G1.5 / 8C16AWG7G1.5 mm² (or 8C × 16 AWG)IEC 60228 Class 5/6 Cu/SnCu12.22353.670
ROBUST 210 300 12G2.5 / 16C16AWG12G2.5 mm² (or 16C × 16 AWG)IEC 60228 Class 5/6 Cu/SnCu17.45107.5105
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification)DC resistance at 20 °C, optical attenuation and wall thickness within EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification)Zero dielectric breakdown and verified wet insulation resistance for 300/500 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −50…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50525 / ECOLAB CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX ROBUST 210 300/500V EN 50525 / ECOLAB 300/500 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define ROBUST 210 300/500V (ROBUST 210 Chemical & Bio-Oil Control Cable)?
ROBUST 210 300/500V (ROBUST 210 Chemical & Bio-Oil Control Cable) is manufactured in accordance with EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification for 300/500 V subsea,ROV and marine aquaculture service over -50 to +80 °C. Its 4-layer construction comprises flexible stranded copper conductors (5 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for ROBUST 210 300/500V?
The minimum bending radius for ROBUST 210 300/500V is 4 × OD across its continuous operating temperature range of -50 to +80 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of ROBUST 210 300/500V arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Flexible Stranded Copper Conductors (5 Cores) — Class 5 / class 6 copper conductors; (02) Cross-Linked Elastomeric / Polymer Core Insulation — Thermoplastic elastomer (tpe) core insulation; (03) Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap; (04) Subsea / Marine Outer Protective Sheath — Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath.
What factory test certificates are supplied with ROBUST 210 300/500V?
Every production drum of ROBUST 210 300/500V undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per EN 50525 & ECOLAB Chemical & Bio-Oil Resistant TPE Control Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for ROBUST 210 300/500V

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

ROBUST 210 300/500V ROBUST 210 Chemical & Bio-Oil Control Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp