Contact
heavy-duty subsea mining, trencher & excavation trailing cableAS/NZS 1802 / AS/NZS 28021.1/1.1 kV (-25 to +90 °C)Subsea / Marine Outer Protective She

AS/NZS 1802 Type 210 Heavy Reeling Mining CableAS/NZS 1802 / AS/NZS 2802 — 1.1/1.1 kV — -25 to +90 °C Subsea & Marine Cable

AS/NZS 1802 Type 210 Heavy Reeling Mining Cable featuring main phase conductors (3 cores) and subsea / marine outer protective sheath (AS/NZS 1802 / AS/NZS 2802, 1.1/1.1 kV, -25 to +90 °C, min. bend radius 6 × OD).

Water-resistant
Oil-resistant
Outdoor & humid
Approved
Order designation
AS/NZS 1802 Type 210 R 4G4.0 mm²
Outer Ø ≈
14.2 mm
Net weight ≈
340 kg/km
Max. pulling ≈
3.2 kN
Core / stranding
IEC 60228 Class 5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.1/1.1 kV
Tested per AS/NZS 1802 / AS/NZS 2802
Operating temp.
−25…+90 °C
Subsea, deck & cold-water duty
Min. bend radius
6 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Main Phase Condu
Flexible stranded copper conductors with
Outer protection
Subsea / Marine
Black heavy-duty polychloroprene (PCP /
Standard
AS/NZS 1802 / AS
AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy

Typical values for this cable type, based on AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is AS/NZS 1802 Type 210 Reeling Mining right for your machine?

AS/NZS 1802 Type 210 Heavy Reeling Mining Cable featuring main phase conductors (3 cores) and subsea / marine outer protective sheath (AS/NZS 1802 / AS/NZS 2802, 1.1/1.1 kV, -25 to +90 °C, min. bend radius 6 × OD).

Trailing & towing

Suitable

Extra-heavy polychloroprene/CSM elastomer jackets and symmetrical earth/pilot cores survive severe seabed rock abrasion and crawler drag.

Cylindrical / multi-layer drum

Suitable

Aramid anti-torsion textile reinforcement supports mobile reeling drums on subsea trenching ploughs, cutter-suction dredgers and mine shov

Immersion & wet locations

Suitable

Vulcanized dual-layer rubber sheath resists high-pressure seawater immersion, benthic mud, oil and acid mine water.

Offshore platform & shipboard deck trays

Suitable

Withstands extreme mechanical crush, impact and UV exposure on mining support vessels and open-cast excavation benches.

Energy chain / drag chain

Not suitable

Large-diameter mining and subsea trencher trailing cables are not intended for compact factory energy chains.

Use FD 855 P Power Chain Cable
Typical machinesMining & TunnellingDeep-Sea Polymetallic Nodule Mining Collectors & RisersSubsea Pipeline Ploughs, Jet Trenchers & Rock CuttersAS/NZS 1802 & VDE MTO Open-Cast Mining Shovels & DraglinesSubmersible Dredging Pumps & Underwater Tunneling Machines

Construction

Layer by layer

Shown: AS/NZS 1802 Type 210 Reeling Mining (AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard) featuring main phase conductors (3 cores), interstitial split earth / pilot cores (3 cores) and subsea / marine outer protective sheath (3-layer construction).

AS/NZS 1802 Type 210 Reeling Mining — stepped horizontal cutaway showing Main Phase Conductors (3 Cores) and Subsea /
Layer cutaway
#LayerMaterial & reference
1Main Phase Conductors (3 Cores)Flexible stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation
2Interstitial Split Earth / Pilot Cores (Symmetrical ground & pilot monitoring conductors in outer valleys
3Subsea / Marine Outer Protective SheathBlack heavy-duty polychloroprene (PCP / EM2 / SGM5) submersible rubber sheath

AS/NZS 1802 Type 210 Reeling Mining — Standard Subsea & Marine Execution

Built to AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard with main phase conductors (3 cores) and subsea / marine outer protective sheath

AS/NZS 1802 Type 210 Reeling Mining — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

AS/NZS 1802 Type 210 Reeling Mining — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1.1/1.1 kV (AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard)
Core / conductor construction
Main Phase Conductors (3 Cores) — Flexible stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation
Primary dielectric / optical buffer
Interstitial Split Earth / Pilot Cores (3 Cores) — Symmetrical ground & pilot monitoring conductors in outer valleys

Thermal

Continuous operating temperature
−25…+90 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −25…+90 °C per AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black heavy-duty polychloroprene (PCP / EM2 / SGM5) submersible rubber sheath
Minimum bending radius
6 × OD
Reinforcement / screen / bedding layer
Interstitial Split Earth / Pilot Cores (3 Cores) — Symmetrical ground & pilot monitoring conductors in outer valleys

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
AS/NZS 1802 Type 210 Reeling Mining
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard AS/NZS 1802 Type 210 Reeling Mining configurations

Manufactured to AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
AS/NZS 1802 Type 210 Reeling Mining Construction Schedule (−25…+90 °C)
AS/NZS 1802 Type 210 R 4G4.0 mm²4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG)IEC 60228 Class 5 Cu/SnCu14.23403.285
AS/NZS 1802 Type 210 R 4G16 mm²4G16 mm² (3×16 + 1G16 / 6 AWG)IEC 60228 Class 5 Cu/SnCu21.48409.6130
AS/NZS 1802 Type 210 R 3×50+1G25 mm²3 × 50 + 1G25 mm² (or 3×70+1G35)IEC 60228 Class 5 Cu/SnCu32.82,24026.5195
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard)DC resistance at 20 °C, optical attenuation and wall thickness within AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard)Zero dielectric breakdown and verified wet insulation resistance for 1.1/1.1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard)Verified hydrostatic pressure integrity, breaking load and flex endurance across −25…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

AS/NZS 1802 / AS/NZS 2802 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX AS/NZS 1802 Type 210 Reeling Mining AS/NZS 1802 / AS/NZS 2802 1.1/1.1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define AS/NZS 1802 Type 210 Reeling Mining (AS/NZS 1802 Type 210 Heavy Reeling Mining Cable)?
AS/NZS 1802 Type 210 Reeling Mining (AS/NZS 1802 Type 210 Heavy Reeling Mining Cable) is manufactured in accordance with AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard for 1.1/1.1 kV subsea,ROV and marine aquaculture service over -25 to +90 °C. Its 3-layer construction comprises main phase conductors (3 cores), interstitial split earth / pilot cores (3 cores) and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for AS/NZS 1802 Type 210 Reeling Mining?
The minimum bending radius for AS/NZS 1802 Type 210 Reeling Mining is 6 × OD across its continuous operating temperature range of -25 to +90 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of AS/NZS 1802 Type 210 Reeling Mining arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Main Phase Conductors (3 Cores) — Flexible stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation; (02) Interstitial Split Earth / Pilot Cores (3 Cores) — Symmetrical ground & pilot monitoring conductors in outer valleys; (03) Subsea / Marine Outer Protective Sheath — Black heavy-duty polychloroprene (PCP / EM2 / SGM5) submersible rubber sheath.
What factory test certificates are supplied with AS/NZS 1802 Type 210 Reeling Mining?
Every production drum of AS/NZS 1802 Type 210 Reeling Mining undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per AS/NZS 1802 & AS/NZS 2802 Type 210 Heavy Reeling & Trailing Mining Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for AS/NZS 1802 Type 210 Reeling Mining

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

AS/NZS 1802 Type 210 Heavy Reeling Mining Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote