Trailing & towing
Extra-heavy polychloroprene/CSM elastomer jackets and symmetrical earth/pilot cores survive severe seabed rock abrasion and crawler drag.
Product
AS/NZS 1802 Type 275 Trailing Mining Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (AS/NZS 1802 / AS/NZS 2802, 3.3/3.3 kV – 11/11 kV, -25 to +90 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard — confirmed in the datasheet and quotation for your order.
Application fit
AS/NZS 1802 Type 275 Trailing Mining Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (AS/NZS 1802 / AS/NZS 2802, 3.3/3.3 kV – 11/11 kV, -25 to +90 °C, min. bend radius 8 × OD).
Extra-heavy polychloroprene/CSM elastomer jackets and symmetrical earth/pilot cores survive severe seabed rock abrasion and crawler drag.
Aramid anti-torsion textile reinforcement supports mobile reeling drums on subsea trenching ploughs, cutter-suction dredgers and mine shov
Vulcanized dual-layer rubber sheath resists high-pressure seawater immersion, benthic mud, oil and acid mine water.
Withstands extreme mechanical crush, impact and UV exposure on mining support vessels and open-cast excavation benches.
Large-diameter mining and subsea trencher trailing cables are not intended for compact factory energy chains.
Use FD 855 P Power Chain CableConstruction
Shown: AS/NZS 1802 Type 275 Trailing Mining (AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Single-Mode / Multi-Mode Optical Unit | Hermetic stainless-steel tube / tight-buffered optical unit |
| 2 | Power & Control Copper Conductors | Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation |
| 3 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard with single-mode / multi-mode optical unit and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| AS/NZS 1802 Type 275 Trailing Mining Construction Schedule (−25…+90 °C) | |||||||
| AS/NZS 1802 Type 275 T Hybrid 4G2.5+FO | 4G2.5 mm² Power + 4×SM + 2×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 14.6 | 285 | 18.0 | 90 | |
| AS/NZS 1802 Type 275 T Hybrid 4G6+FO | 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 19.2 | 540 | 32.0 | 120 | |
| AS/NZS 1802 Type 275 T Hybrid 4G16+FO | 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | Class 5 SnCu + Heavy Aramid + Subsea PUR | 26.5 | 1,120 | 55.0 | 165 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G2.5 mm² Power + 4×SM + 2×2×0.5 | 7.98 | 3.3/3.3 kV – 11/11 kV · 18 kN Tensile | −25…+90 °C |
| 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | 3.30 | 3.3/3.3 kV – 11/11 kV · 32 kN Tensile | −25…+90 °C |
| 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | 1.21 | 3.3/3.3 kV – 11/11 kV · 55 kN Tensile | −25…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard) | Zero dielectric breakdown and verified wet insulation resistance for 3.3/3.3 kV – 11/11 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (AS/NZS 1802 Type 275 Pilot-Monitored Electro-Optical Trailing Mining Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −25…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.