Contact
submarine & offshore armoured optical cableITU-T G.972 / MINISUB LW 8,000 mOptical (-20 to +70 °C)High-Density Polyethylene (HDPE) She

MINISUB LW Up to 192F 8,000 m Full-Ocean-Depth Lightweight Steel-Vault Submarine Optical CableITU-T G.972 / MINISUB LW 8,000 m — Optical — -20 to +70 °C Subsea & Offshore Cable

MINISUB LW Up to 192F 8,000 m Full-Ocean-Depth Lightweight Steel-Vault Submarine Optical Cable (ITU-T G.972 / MINISUB LW 8,000 m) engineered for Optical service across -20 to +70 °C (min. bend radius 20 × OD).

Water-resistant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
MINISUB LW 8000m 4–12F EOM/Sub
Outer Ø ≈
8.2 mm
Net weight ≈
260 kg/km
Tensile rating ≈
48.0 kN
Core / stranding
Laser-welded SS FIMT + Steel/Aramid Armour
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Optical
Tested per ITU-T G.972 / MINISUB LW 8,00
Operating temp.
−20…+70 °C
Continuous subsea & offshore service
Min. bend radius
20 × OD
Winch sheave, chute & seabed routing
Core / conductor
Laser-Welded SS
Hermetic stainless-steel tube housing si
Outer protection
High-Density Pol
High-dielectric black HDPE outer insulat
Standard
ITU-T G.972 / MI
ITU-T G.972 MINISUB LW 8,000 m Full-Ocea

Typical values for this cable type, based on ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is MINISUB LW 8000m right for your machine?

MINISUB LW Up to 192F 8,000 m Full-Ocean-Depth Lightweight Steel-Vault Submarine Optical Cable (ITU-T G.972 / MINISUB LW 8,000 m) engineered for Optical service across -20 to +70 °C (min. bend radius 20 × OD).

Fixed installation

Suitable

Laser-welded stainless-steel / copper-tube FIMT or water-blocked loose-tube construction protects ITU-T G.652D / G.654E / OM3/OM4 fibres.

Immersion & wet locations

Suitable

Hermetic metallic optical tube, steel vault and high-density PE/PUR serving withstand up to 8,000 m deep-ocean hydrostatic pressure.

Offshore platform & shipboard deck trays

Suitable

Galvanized steel or bronze wire armour and SHF2-MUD / PUR / PE jacket resist seabed abrasion, fishing-gear impact, oil and drilling mud.

Drilling jumbo & rotary mast feed

Suitable

NEK 606 QFCU and IEEE 1580 S670T executions maintain high-speed optical telemetry across hazardous offshore topside zones.

Energy chain / drag chain

Not suitable

Submarine and armoured offshore optical cable is not intended for indoor factory automation drag chains.

Use Deepwater ROV Optical Tether
Typical machinesUnderwater & Ocean ExplorationSubmarine Telecom & Cabled Ocean ObservatoriesIsland, Coastal & Inter-Platform Subsea Optical LinksOffshore Platform & FPSO Fire-Safe Optical BackbonesTactical Marine & Harsh-Environment Optical Deployment

Construction

Layer by layer

Shown: MINISUB LW 8000m (ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification) featuring laser-welded ss loose tube (up to 192f), high-tensile steel wire pressure vault and high-density polyethylene (hdpe) sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Laser-Welded SS Loose Tube (Up to 192F)Hermetic stainless-steel tube housing single-mode optical fibers
2High-Tensile Steel Wire Pressure VaultInterlocking steel wire vault rated for 8,000 m ocean depth
3Laser-Welded Copper Power Conductor TubeContinuous copper tube for long-haul DC constant-current feeding
4High-Density Polyethylene (HDPE) SheathHigh-dielectric black HDPE outer insulating & protective jacket

MINISUB LW 8000m — Standard Subsea & Offshore Execution

Built to ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification with laser-welded ss loose tube (up to 192f) and high-density polyethylene (hdpe) sheath

MINISUB LW 8000m — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

MINISUB LW 8000m — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
Optical (ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification)
Core / conductor construction
Laser-Welded SS Loose Tube (Up to 192F) — Hermetic stainless-steel tube housing single-mode optical fibers
Primary dielectric / buffering
High-Tensile Steel Wire Pressure Vault — Interlocking steel wire vault rated for 8,000 m ocean depth

Thermal

Continuous operating temperature
−20…+70 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
High-Density Polyethylene (HDPE) Sheath — High-dielectric black HDPE outer insulating & protective jacket
Minimum bending radius
20 × OD
Armour, strength member & mechanical duty
Laser-Welded Copper Power Conductor Tube — Continuous copper tube for long-haul DC constant-current feeding

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
MINISUB LW 8000m
Sheath colour & metre marking
Continuous metre-marked black outer finish (High-Density Pol)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard MINISUB LW 8000m subsea & offshore configurations

Manufactured to ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
MINISUB LW 8000m Construction Schedule (−20…+70 °C)
MINISUB LW 8000m 4–12F EOM/Sub4–12 × ITU-T G.652D / G.654E SM (+ Power)Laser-welded SS FIMT + Steel/Aramid Armour8.226048.0125
MINISUB LW 8000m 24–48F EOM/Sub24–48 × ITU-T G.652D / G.654E SM (+ Power)Laser-welded SS FIMT + Contra-Helical Steel17.5680120.0260
MINISUB LW 8000m 96–192F Trunk96–192 × ITU-T G.654E / G.652D SubmarineSS Tube + Steel Vault + Cu Tube + DA Armour28.01,650300.0420
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification)DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification)Zero dielectric breakdown and verified insulation resistance for Optical ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −20…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ITU-T G.972 / MINISUB LW 8,000 m CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX MINISUB LW 8000m ITU-T G.972 / MINISUB LW 8,000 m Optical CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define MINISUB LW 8000m (MINISUB LW Up to 192F 8,000 m Full-Ocean-Depth Lightweight Steel-Vault Submarine Optical Cable)?
MINISUB LW 8000m (MINISUB LW Up to 192F 8,000 m Full-Ocean-Depth Lightweight Steel-Vault Submarine Optical Cable) is manufactured in accordance with ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification for Optical service over -20 to +70 °C. Its 4-layer construction comprises laser-welded ss loose tube (up to 192f), high-tensile steel wire pressure vault and high-density polyethylene (hdpe) sheath.
What is the minimum bending radius and operating temperature range for MINISUB LW 8000m?
The minimum bending radius for MINISUB LW 8000m is 20 × OD across its continuous operating temperature range of -20 to +70 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of MINISUB LW 8000m arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Laser-Welded SS Loose Tube (Up to 192F) — Hermetic stainless-steel tube housing single-mode optical fibers; (02) High-Tensile Steel Wire Pressure Vault — Interlocking steel wire vault rated for 8,000 m ocean depth; (03) Laser-Welded Copper Power Conductor Tube — Continuous copper tube for long-haul DC constant-current feeding; (04) High-Density Polyethylene (HDPE) Sheath — High-dielectric black HDPE outer insulating & protective jacket.
What factory test certificates are supplied with MINISUB LW 8000m?
Every production drum of MINISUB LW 8000m undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per ITU-T G.972 MINISUB LW 8,000 m Full-Ocean-Depth Lightweight Submarine Optical Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for MINISUB LW 8000m

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

MINISUB LW 8000m MINISUB LW Up to 192F 8,000 m Full-Ocean-Depth Lightweight Steel-Vault Submarine Optical Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote