Fixed installation
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per DIN VDE 0285 / IEC 60228 Class 6 (HF25G0.75CY (350CY) 300/500V VDE) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Fine-stranded copper conductors withstand routine equipment vibration and occasional flexing.
Fine-stranded copper cores and low-friction cabling support multi-million-cycle linear carrier travel.
Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableUV- and ozone-resistant 300/500 V PVC insulation delivers long outdoor service life across utility solar PV strings and inverter combiners.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | 25×0.75mm² Super-Fine Bare Copper | IEC 60228 Class 6 Extra-Fine Stranded Bare Copper |
| 2 | Modified PVC Insulation (24 Black + 1 G/Y) | White Numbered Black Cores + Green/Yellow Earth |
| 3 | Extruded Grey PVC Inner Bedding Jacket | Core-Stabilizing Inner Sheath for Drag-Chain Duty |
| 4 | 85% Tinned Copper Wire Braid Shield (CY) | 360° EMC Braided Tinned Copper Screen |
| 5 | Oil-Resistant Grey PVC Outer Jacket | DIN VDE 0285 / EN 50618 High-Flex PVC Sheath (16.4 mm OD) |
IEC 60228 Class 6 Cu + Inner Jacket + 85% TCWB · Outer diameter 16.4 mm.
IEC 60228 Class 6 Cu + Inner Jacket + 85% TCWB · Outer diameter 12.1 mm.
IEC 60228 Class 6 Cu + Inner Jacket + 85% TCWB · Outer diameter 14.2 mm.
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HF25G0.75CY (350CY) 300/500V VDE | |||||||||||
| 25G0.75 mm² (24 Numbered + 1 G/Y) | IEC 60228 Class 6 Cu + Inner Jacket + 85% TCWB | White Numbered Black Cores + Green/Yellow Earth | Industrial PVC | 16.4 | 123 | 26.00 | 252.0 | 462 | 300/500 V (9 A · 4 kV AC Test) | HF25G0.75CY (350CY) 25G0.75 mm² | |
| 12G0.75 mm² (11 Numbered + 1 G/Y) | IEC 60228 Class 6 Cu + Inner Jacket + 85% TCWB | White Numbered Black Cores + Green/Yellow Earth | Industrial PVC | 12.1 | 91 | 26.00 | 128.0 | 238 | 300/500 V (12 A · 4 kV AC Test) | HF12G0.75CY (350CY) 12G0.75 mm² | |
| 18G0.75 mm² (17 Numbered + 1 G/Y) | IEC 60228 Class 6 Cu + Inner Jacket + 85% TCWB | White Numbered Black Cores + Green/Yellow Earth | Industrial PVC | 14.2 | 107 | 26.00 | 184.0 | 336 | 300/500 V (10 A · 4 kV AC Test) | HF18G0.75CY (350CY) 18G0.75 mm² | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation or shield | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing within standard char limit | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.