73000W Series (73805W) 600V UL AWM 2587 Moderate-Flex Control CableUL AWM Style 2587 / CSA AWM I/II A/B FT1 (600 V, -40 to +90 °C) unshielded 5G18 AWG (16×30) flexible bare copper oil-resistant moderate-flex control cable for machine tools.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Oil-resistant
Flame-retardant
Approved
Order designation
73805W 5G18 AWG (4C + G/Y)
Outer diameter
8.3 mm
Cable weight
104 kg/km
Min. bend radius
66 mm
Conductor & shield
16×30 AWG Bare Cu + 0.56mm Lubricated PVC
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
UL AWM Style 2587 / CSA AWM I/II A/B
Temperature
−40…+90 °C
Fixed / flex duty
Min. bend radius
8 × OD
8.3–9.7 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per UL AWM Style 2587 / CSA AWM I/II A/B (73000W Series (73805W) 600V UL AWM 2587) — confirmed in the datasheet and quotation for your order.

Application fit

Is 73000W Series (73805W) 600V UL AWM 2587 right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for open cable tray, raceway and supported industrial runs per standard installation rules.

Motor stator, traction & converter leads

Suitable

Fine-stranded copper conductors withstand routine equipment vibration and occasional flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

6-axis robot arm & torsion dress pack

Suitable

Multi-axis torsion-capable 600 V PVC stranding handles continuous robotic dress-pack twisting and automated assembly cells.

Typical machinesIndustrial Automation CableIndustrial automation & control cabinetsInverter-fed motor drive systemsProcess instrumentation & oil/gas skidsMachine tools & robotic cellsData centers, stadiums & broadcast facilities

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

73000W Series (73805W) 600V UL AWM 2587 – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
15×18 AWG (16×30) Flexible Bare Copper16×30 AWG (0.81 mm² · 16×0.25 mm) Flexible Bare Copper
2Lubricated PVC Insulation (4 Black + 1 G/Y)0.56 mm Lubricated PVC (4 White-Numbered + 1 Green/Yellow)
3Low-Friction Non-Woven Tissue SeparatorFlex-Facilitating Core Wrap & Ripcord
4Slate Grey Oil-Resistant PVC Outer JacketUL AWM Style 2587 / CSA AWM I/II A/B FT1 Sheath (8.28 mm OD)

5G18 AWG (5 × 0.81 mm² · 16×30 AWG)

16×30 AWG Bare Cu + 0.56mm Lubricated PVC · Outer diameter 8.28 mm.

12G18 AWG (12 × 0.81 mm² · 16×30 AWG)

16×30 AWG Bare Cu + 0.56mm Lubricated PVC · Outer diameter 12.6 mm.

5G16 AWG (5 × 1.31 mm² · 26×30 AWG)

26×30 AWG Bare Cu + 0.56mm Lubricated PVC · Outer diameter 9.65 mm.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per UL AWM Style 2587 / CSA AWM I/II A/B (73000W Series (73805W) 600V UL AWM 2587). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
600 V
Conductor & core insulation
16×30 AWG (0.81 mm² · 16×0.25 mm) Flexible Bare Copper · 0.56 mm Lubricated PVC (4 White-Numbered + 1 Green/Yellow)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
−40…+90 °C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
UL AWM Style 2587 / CSA AWM I/II A/B

Mechanical

Minimum bending radius
8 × OD
Screening / armour architecture
Unshielded multi-core construction · mechanical protection via outer jacket
Outer sheath material & colour
UL AWM Style 2587 / CSA AWM I/II A/B FT1 Sheath (8.28 mm OD)

Reference standards

Reference standard
UL AWM Style 2587 / CSA C22.2 No. 210 AWM I/II A/B FT1 / UL Oil Res I & II / NFPA 79
Hazardous Substance Compliance
CE, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
73000W Series (73805W) 600V UL AWM 2587
5G18 AWG (5 × 0.81 mm² · 16×30 AWG)16×30 AWG Bare Cu + 0.56mm Lubricated PVC0.56 mm Lubricated PVC (4 White-Numbered + 1 Green/Yellow)Industrial PVC8.36621.4038.9104600 V UL AWM 2587 (10 A · 90 °C)73805W 5G18 AWG (4C + G/Y)
12G18 AWG (12 × 0.81 mm² · 16×30 AWG)16×30 AWG Bare Cu + 0.56mm Lubricated PVC0.56 mm Lubricated PVC (4 White-Numbered + 1 Green/Yellow)Industrial PVC12.610121.4093.4228600 V UL AWM 2587 (7 A · 90 °C)73812W 12G18 AWG (11C + G/Y)
5G16 AWG (5 × 1.31 mm² · 26×30 AWG)26×30 AWG Bare Cu + 0.56mm Lubricated PVC0.56 mm Lubricated PVC (4 White-Numbered + 1 Green/Yellow)Industrial PVC9.77713.5062.9145600 V UL AWM 2587 (13 A · 90 °C)73605W 5G16 AWG (4C + G/Y)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °CEvery manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation or shieldEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing within standard char limitType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 2587 / CSA AWM I/II A/B CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 73000W SERIES (73805W) 600V UL AWM 2587 UL AWM STYLE 2587 / CSA AWM I/II A/B 600 V CE ROHS — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
305 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-03
Updated
2026-11-03

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is 73000W Series (73805W) 600V UL AWM 2587 designed for?
73000W Series (73805W) 600V UL AWM 2587 is engineered for industrial installations under UL AWM Style 2587 / CSA AWM I/II A/B, operating over −40…+90 °C with a minimum bending radius of 8 × OD.
How does the construction of 73000W Series (73805W) 600V UL AWM 2587 protect signal and power integrity?
Its multi-layer build combines 5×18 AWG (16×30) Flexible Bare Copper with Lubricated PVC Insulation (4 Black + 1 G/Y) and Slate Grey Oil-Resistant PVC Outer Jacket to ensure mechanical stability and electrical performance.
What standards and fire ratings apply to 73000W Series (73805W) 600V UL AWM 2587?
The cable is qualified to UL AWM Style 2587 / CSA C22.2 No. 210 AWM I/II A/B FT1 / UL Oil Res I & II / NFPA 79, meeting vertical flame propagation and industrial jacket durability requirements.
Can 73000W Series (73805W) 600V UL AWM 2587 be supplied in custom lengths or configurations?
Yes. Standard configurations include 73805W 5G18 AWG (4C + G/Y), 73812W 12G18 AWG (11C + G/Y) and 73605W 5G16 AWG (4C + G/Y), supplied on 305 m, 500 m or 1,000 m export drums.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 73000W Series (73805W) 600V UL AWM 2587

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

73000W Series (73805W) 600V UL AWM 2587 Moderate-Flex Control Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote