H05V2V2D3-F 300/500 V Pendant Control Cable with Dual Steel WireDIN VDE 0285 / BS EN 50525 · 300/500 V · -25 °C to +90 °C industrial H05V2V2D3-F construction

H05V2V2D3-F 300/500 V Pendant Control Cable with Dual Steel Wire Strain-Relief Messengers (H05V2V2D3-F) engineered to DIN VDE 0285 / BS EN 50525 for 300/500 V service across -25 °C to +90 °C, featuring stranded copper / steel conductor and pvc tm3 outer sheath

Approved
Oil-resistant
Flame-retardant
Order designation
H05V2V2D3-F 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Per DIN VDE 0285 / BS EN 50525
Operating temp.
−25…+90 °C
Continuous thermal rating
Min. bend radius
8 × OD
Installed / fixed routing
Conductor
copper / steel
High-conductivity copper / steel
Outer layer
PVC TM3 outer
Extruded PVC TM3 outer sheath
Standard
DIN VDE 0285
DIN VDE 0285 / BS EN 50525

Typical values for this cable type, based on DIN VDE 0285 / BS EN 50525 — confirmed in the datasheet and quotation for your order.

Application fit

Is H05V2V2D3-F right for your machine?

H05V2V2D3-F 300/500 V Pendant Control Cable with Dual Steel Wire Strain-Relief Messengers (H05V2V2D3-F) engineered to DIN VDE 0285 / BS EN 50525 for 300/500 V service across -25 °C to +90 °C, featuring stranded copper / steel conductor and pvc tm3 outer sheath

Self-supporting pendant & push-button drop

Suitable

Engineered and verified for pendant station service in accordance with DIN VDE 0285 / BS EN 50525.

Free-hanging vertical run

Suitable

Engineered and verified for hanging service in accordance with DIN VDE 0285 / BS EN 50525.

Fixed installation

Suitable

Qualified for fixed installation on trays, racks, conduits or supports per DIN VDE 0285 / BS EN 50525.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 8 × OD bend radius.

Typical machinesCranes & Material HandlingOverhead Bridge & Gantry Crane PendantsHoist, Trolley & Monorail Control StationsIndustrial Lifting & Material HandlingWarehouse & Port AutomationAutomated Assembly & Packaging Lines

Construction

Layer by layer

Shown: H05V2V2D3-F (DIN VDE 0285 / BS EN 50525) with stranded copper / steel conductor, pvc ti3 core insulation and pvc tm3 outer sheath (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper / steel conductorHigh-conductivity copper / steel conductor per DIN VDE 0285 / BS EN 50525DIN VDE 0285 / BS EN 50525
2PVC TI3 core insulationExtruded PVC TI3 dielectric (individual core / group layer)DIN VDE 0285 / BS EN 50525
3PVC TM3 outer sheathExtruded PVC TM3 outer sheath protective layer (continuous layer)DIN VDE 0285 / BS EN 50525

H05V2V2D3-F — Standard Execution

Built to DIN VDE 0285 / BS EN 50525 with stranded copper / steel conductor and pvc tm3 outer sheath

H05V2V2D3-F — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per DIN VDE 0285 / BS EN 50525

H05V2V2D3-F — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0285 / BS EN 50525. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300/500 V (DIN VDE 0285 / BS EN 50525)
Conductor construction
Stranded copper / steel conductor — High-conductivity copper / steel conductor per DIN VDE 0285 / BS EN 50525
Primary insulation / dielectric
PVC TI3 core insulation — Extruded PVC TI3 dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−25…+90 °C per DIN VDE 0285 / BS EN 50525
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC TM3 outer sheath — Extruded PVC TM3 outer sheath protective layer (continuous layer)
Minimum bending radius
8 × OD (installed / static routing)
Layer count & geometry
3 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with DIN VDE 0285 / BS EN 50525
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
DIN VDE 0285 / BS EN 50525
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
H05V2V2D3-F
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard H05V2V2D3-F cable sizes

Manufactured to DIN VDE 0285 / BS EN 50525 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
H05V2V2D3-F Standard Production Schedule (300/500 V · −25…+90 °C)
H05V2V2D3-F 3G1.53 × 1.5 mm²8.410568
H05V2V2D3-F 4G1.54 × 1.5 mm²9.212874
H05V2V2D3-F 5G1.55 × 1.5 mm²10.115681
H05V2V2D3-F 3G2.53 × 2.5 mm²9.814878
H05V2V2D3-F 4G2.54 × 2.5 mm²10.818686
H05V2V2D3-F 5G2.55 × 2.5 mm²11.922895
H05V2V2D3-F 4G44 × 4.0 mm²12.6268101
H05V2V2D3-F 4G64 × 6.0 mm²14.2365114
H05V2V2D3-F 4G104 × 10 mm²17.5580140
H05V2V2D3-F 4G164 × 16 mm²20.4845163
H05V2V2D3-F 4G254 × 25 mm²24.81,290198
H05V2V2D3-F 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per DIN VDE 0285 / BS EN 50525.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (DIN VDE 0285 / BS EN 50525)DC resistance at 20 °C and geometry within DIN VDE 0285 / BS EN 50525 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (DIN VDE 0285 / BS EN 50525)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (DIN VDE 0285 / BS EN 50525)Full compliance with DIN VDE 0285 / BS EN 50525 across −25…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0285 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX H05V2V2D3-F <size> DIN VDE 0285 300/500 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define H05V2V2D3-F (H05V2V2D3-F 300/500 V Pendant Control Cable with Dual Steel Wire Strain-Relief Messengers)?
H05V2V2D3-F (H05V2V2D3-F 300/500 V Pendant Control Cable with Dual Steel Wire Strain-Relief Messengers) is manufactured in accordance with DIN VDE 0285 / BS EN 50525 for 300/500 V service over -25 °C to +90 °C. Its 3-layer construction comprises stranded copper / steel conductor, pvc ti3 core insulation, pvc tm3 outer sheath.
What is the minimum bending radius and installation temperature for H05V2V2D3-F?
The minimum installed bending radius for H05V2V2D3-F is 8 × OD across its continuous operating temperature range of -25 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of H05V2V2D3-F arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper / steel conductor (High-conductivity copper / steel conductor per DIN VDE 0285 / BS EN 50525); (02) PVC TI3 core insulation (Extruded PVC TI3 dielectric (individual core / group layer)); (03) PVC TM3 outer sheath (Extruded PVC TM3 outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with H05V2V2D3-F?
Every production drum or spool of H05V2V2D3-F undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per DIN VDE 0285 / BS EN 50525, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for H05V2V2D3-F

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

H05V2V2D3-F 300/500 V Pendant Control Cable with Dual Steel Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote