Contact
aquaculture feeder drag-chain & subsea robotic torsion cableDIN VDE 0285 / UL AWM300/500 V (-35 to +100 °C)Subsea / Marine Outer Protective She

CF9 TPE Bio-Oil & UV Resistant Feeder CableDIN VDE 0285 / UL AWM — 300/500 V — -35 to +100 °C Subsea & Marine Cable

CF9 TPE Bio-Oil & UV Resistant Feeder Cable featuring flexible stranded copper conductors (12 cores) and subsea / marine outer protective sheath (DIN VDE 0285 / UL AWM, 300/500 V, -35 to +100 °C, min. bend radius 5 × OD).

Water-resistant
Oil-resistant
Outdoor & humid
Approved
Order designation
CF9 TPE Bio-Oil UV Chain 4G1.5 / 5C18AWG
Outer Ø ≈
9.6 mm
Net weight ≈
145 kg/km
Max. pulling ≈
2.2 kN
Core / stranding
IEC 60228 Class 5/6 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Tested per DIN VDE 0285 / UL AWM
Operating temp.
−35…+100 °C
Subsea, deck & cold-water duty
Min. bend radius
5 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Flexible Strande
Class 5 / class 6 copper conductors
Outer protection
Subsea / Marine
Black chemical- & bio-oil-resistant ther
Standard
DIN VDE 0285 / U
DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resist

Typical values for this cable type, based on DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is CF9 TPE Bio-Oil UV Chain right for your machine?

CF9 TPE Bio-Oil & UV Resistant Feeder Cable featuring flexible stranded copper conductors (12 cores) and subsea / marine outer protective sheath (DIN VDE 0285 / UL AWM, 300/500 V, -35 to +100 °C, min. bend radius 5 × OD).

Energy chain / drag chain

Suitable

Short-pitch Class 6 copper stranding and low-adhesion TPE/PUR jackets deliver multi-million-cycle life in horizontal and self-supporting d

Free-hanging vertical run

Suitable

Robotic torsion (RF-Torsion) and coiled spiral builds absorb ±180°/m to ±360°/m multi-axis twist on ROV pan-and-tilt and manipulator wrist

Immersion & wet locations

Suitable

Hydrolysis-, seawater-, fish-oil- and UV-resistant outer jackets operate reliably above open fish tanks and coastal feed tracks.

Switchgear & control cabinet wiring

Suitable

High-coverage tinned copper braided screens protect encoder, load-cell and servo signals from VFD interference.

Vertical / spreader reel

Not suitable

Drag-chain and robotic wrist cables are not designed for high-tension deep-ocean vertical lift winches.

Use RM0045 Heavy ROV Umbilical
Typical machinesIndustrial Automation CableAutomated Aquaculture Rail & Gantry Feeding SystemsSubsea ROV Electric Manipulator Wrists & Pan-Tilt UnitsHatchery Grading, Vaccination & Fish-Counting AutomationSeafood Cold-Storage & Automated Packaging Drag Chains

Construction

Layer by layer

Shown: CF9 TPE Bio-Oil UV Chain (DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard) featuring flexible stranded copper conductors (12 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

CF9 TPE Bio-Oil UV Chain — stepped horizontal cutaway showing Flexible Stranded Copper Conductors (12 Cores) and Subse
Layer cutaway
#LayerMaterial & reference
1Flexible Stranded Copper Conductors (12 Class 5 / class 6 copper conductors
2Cross-Linked Elastomeric / Polymer Core Thermoplastic elastomer (tpe) core insulation
3Water-Blocking Tape & Inner BeddingHydrostatic water-blocking filler and low-friction separator wrap
4Subsea / Marine Outer Protective SheathBlack chemical- & bio-oil-resistant thermoplastic elastomer (TPE) outer sheath

CF9 TPE Bio-Oil UV Chain — Standard Subsea & Marine Execution

Built to DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard with flexible stranded copper conductors (12 cores) and subsea / marine outer protective sheath

CF9 TPE Bio-Oil UV Chain — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

CF9 TPE Bio-Oil UV Chain — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
300/500 V (DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard)
Core / conductor construction
Flexible Stranded Copper Conductors (12 Cores) — Class 5 / class 6 copper conductors
Primary dielectric / optical buffer
Cross-Linked Elastomeric / Polymer Core Insulation — Thermoplastic elastomer (tpe) core insulation

Thermal

Continuous operating temperature
−35…+100 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −35…+100 °C per DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black chemical- & bio-oil-resistant thermoplastic elastomer (TPE) outer sheath
Minimum bending radius
5 × OD
Reinforcement / screen / bedding layer
Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CF9 TPE Bio-Oil UV Chain
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard CF9 TPE Bio-Oil UV Chain configurations

Manufactured to DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
CF9 TPE Bio-Oil UV Chain Construction Schedule (−35…+100 °C)
CF9 TPE Bio-Oil UV Chain 4G1.5 / 5C18AWG4G1.5 mm² (or 5C × 18 AWG)IEC 60228 Class 5/6 Cu/SnCu9.61452.255
CF9 TPE Bio-Oil UV Chain 7G1.5 / 8C16AWG7G1.5 mm² (or 8C × 16 AWG)IEC 60228 Class 5/6 Cu/SnCu12.22353.670
CF9 TPE Bio-Oil UV Chain 12G2.5 / 16C16AWG12G2.5 mm² (or 16C × 16 AWG)IEC 60228 Class 5/6 Cu/SnCu17.45107.5105
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard)DC resistance at 20 °C, optical attenuation and wall thickness within DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard)Zero dielectric breakdown and verified wet insulation resistance for 300/500 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard)Verified hydrostatic pressure integrity, breaking load and flex endurance across −35…+100 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0285 / UL AWM CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CF9 TPE Bio-Oil UV Chain DIN VDE 0285 / UL AWM 300/500 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CF9 TPE Bio-Oil UV Chain (CF9 TPE Bio-Oil & UV Resistant Feeder Cable)?
CF9 TPE Bio-Oil UV Chain (CF9 TPE Bio-Oil & UV Resistant Feeder Cable) is manufactured in accordance with DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard for 300/500 V subsea,ROV and marine aquaculture service over -35 to +100 °C. Its 4-layer construction comprises flexible stranded copper conductors (12 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for CF9 TPE Bio-Oil UV Chain?
The minimum bending radius for CF9 TPE Bio-Oil UV Chain is 5 × OD across its continuous operating temperature range of -35 to +100 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of CF9 TPE Bio-Oil UV Chain arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Flexible Stranded Copper Conductors (12 Cores) — Class 5 / class 6 copper conductors; (02) Cross-Linked Elastomeric / Polymer Core Insulation — Thermoplastic elastomer (tpe) core insulation; (03) Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap; (04) Subsea / Marine Outer Protective Sheath — Black chemical- & bio-oil-resistant thermoplastic elastomer (TPE) outer sheath.
What factory test certificates are supplied with CF9 TPE Bio-Oil UV Chain?
Every production drum of CF9 TPE Bio-Oil UV Chain undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per DIN VDE 0285 CF9 TPE Bio-Oil & UV-Resistant Drag-Chain Feeder Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CF9 TPE Bio-Oil UV Chain

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CF9 TPE Bio-Oil UV Chain CF9 TPE Bio-Oil & UV Resistant Feeder Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote