Energy chain / drag chain
Short-pitch Class 6 copper stranding and low-adhesion TPE/PUR jackets deliver multi-million-cycle life in horizontal and self-supporting d
Product
KF-6530 SK-TP-C-PUR Robot Data Cable featuring stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath (DIN VDE 0812 / UL AWM 20233, 300 V, -40 to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification — confirmed in the datasheet and quotation for your order.
Application fit
KF-6530 SK-TP-C-PUR Robot Data Cable featuring stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath (DIN VDE 0812 / UL AWM 20233, 300 V, -40 to +80 °C, min. bend radius 6 × OD).
Short-pitch Class 6 copper stranding and low-adhesion TPE/PUR jackets deliver multi-million-cycle life in horizontal and self-supporting d
Robotic torsion (RF-Torsion) and coiled spiral builds absorb ±180°/m to ±360°/m multi-axis twist on ROV pan-and-tilt and manipulator wrist
Hydrolysis-, seawater-, fish-oil- and UV-resistant outer jackets operate reliably above open fish tanks and coastal feed tracks.
High-coverage tinned copper braided screens protect encoder, load-cell and servo signals from VFD interference.
Drag-chain and robotic wrist cables are not designed for high-tension deep-ocean vertical lift winches.
Use RM0045 Heavy ROV UmbilicalConstruction
Shown: KF-6530 SK-TP-C-PUR Robot Data (DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification) featuring stranded copper twisted pairs (2×2), low-capacitance core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Twisted Pairs (2×2) | Twisted pairs |
| 2 | Low-Capacitance Core Insulation | High-density polyethylene (hdpe / pe) core insulation |
| 3 | Foil Screen & Water-Blocking Separator | 100% Al/PET foil electrostatic screen with water-blocking binder tape |
| 4 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification with stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| KF-6530 SK-TP-C-PUR Robot Data Construction Schedule (−40…+80 °C) | |||||||
| KF-6530 SK-TP-C-PUR Robot Data 1×2×22AWG RS-485 | 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | Stranded SnCu + Foam PE + Foil/Braid | 8.2 | 92 | 2.0 | 50 | |
| KF-6530 SK-TP-C-PUR Robot Data 4×2×24AWG Cat5e | 4 × 2 × 24 AWG Subsea Gigabit Ethernet | Stranded SnCu + High-Pressure PE + SF/UTP | 9.6 | 125 | 3.5 | 60 | |
| KF-6530 SK-TP-C-PUR Robot Data 4×2×23AWG Cat6+2C | 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | Stranded SnCu + 600-Bar Matrix + PUR | 12.8 | 215 | 6.8 | 78 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | 55.00 | 300 V (120 Ω RS-485) | −40…+80 °C |
| 4 × 2 × 24 AWG Subsea Gigabit Ethernet | 84.00 | 300 V (100 Ω 1000BASE-T) | −40…+80 °C |
| 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | 72.00 | 300 V (100 Ω Cat6 6000m) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification) | Zero dielectric breakdown and verified wet insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (DIN VDE 0812 KF-6530 SK-TP-C-PUR Robotic & Crawler Data Cable Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.