Contact
845 kN steel-armoured work-class ROV & subsea plow umbilicalSAE AS81044 / ISO 13628-53,000–7,000 V AC + 2.4 kV845 kN Heavy-Lift SWA

A304562 Series 3.0–7.0 kV (845 kN) Steel-Armoured ROV & Plow UmbilicalSAE AS81044 / ISO 13628-5 · 3.6/6 kV · 845 kn steel-armoured work-class rov & subsea

A304562, A304613, A304493, A304267, A304822, A304835, A304982 & A304472 Heavy-Lift Steel-Armoured Work-Class ROV & Subsea Plow Electro-Optical Umbilical Series (SAE AS81044 / ISO 13628-5, 3.6/6 kV, -40 °C to +80 °C).

Water-resistant
Anti-torsion braid
EMC screen
Oil-resistant
Order designation
A304562 Type A (Standard Lift)
Outer Ø ≈
25.4 mm
Net weight ≈
1,680 kg/km
Tensile rating ≈
320.0 kN
Core / stranding
Class 5 tinned Cu + 316L FIMT
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
3.6/6 kV
Tested per SAE AS81044 / ISO 13628-5
Operating temp.
−40…+80 °C
Continuous subsea & marine service
Min. bend radius
15 × OD
Dynamic sheave & fixed routing
Core / conductor
3–7 kV Power
3,000–7,000 V AC power + 2,400 V control
Outer protection
845 kN
Preformed double high-carbon GSWA
Standard
SAE AS81044
SAE AS81044

Typical values for this cable type, based on SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow — confirmed in the datasheet and quotation for your order.

Application fit

Is A304562 right for your machine?

A304562, A304613, A304493, A304267, A304822, A304835, A304982 & A304472 Heavy-Lift Steel-Armoured Work-Class ROV & Subsea Plow Electro-Optical Umbilical Series (SAE AS81044 / ISO 13628-5, 3.6/6 kV, -40 °C to +80 °C).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: A304562 (SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow) featuring optical package (7×smf), coaxial & signal cores (1 coax + 4 sig) and torque-balanced steel armour (845 kn) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Optical Package (7×SMF)Laser-welded stainless-steel tube / Stainless-Steel-Tube package for 6,000 m depth
2Coaxial & Signal Cores (1 Coax + 4 Sig)19-strand tinned copper + SAE AS81044 (SPEC 44) dual-wall irradiated insulation
3HV Power Conductors (20 Cores)Stranded tinned copper with 3,000–7,000 V AC SPEC 44 / XLPE insulation
4Ground Tape, Overall Braid & Elastomer BeltWater-blocked core + Cu/PET tape + tinned Cu braid + Elastomer inner sheath
5Torque-Balanced Steel Armour (845 kN)Preformed contra-helical high-carbon galvanized steel wire armour

A304562 — Standard Subsea & Marine Execution

Built to SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow with optical package (7×smf) and torque-balanced steel armour (845 kn)

A304562 — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

A304562 — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
3.6/6 kV (SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow)
Core / conductor construction
Optical Package (7×SMF) — Laser-welded stainless-steel tube / Stainless-Steel-Tube package for 6,000 m depth
Primary dielectric / buffering
Coaxial & Signal Cores (1 Coax + 4 Sig) — 19-strand tinned copper + SAE AS81044 (SPEC 44) dual-wall irradiated insulation

Thermal

Continuous operating temperature
−40…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Torque-Balanced Steel Armour (845 kN) — Preformed contra-helical high-carbon galvanized steel wire armour
Minimum bending radius
15 × OD
Hydrostatic, tensile & crush duty
Ground Tape, Overall Braid & Elastomer Belt — Water-blocked core + Cu/PET tape + tinned Cu braid + Elastomer inner sheath

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
A304562
Sheath colour & metre marking
Continuous metre-marked black outer finish (845 kN Torque-Bal SWA)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard A304562 subsea & marine configurations

Manufactured to SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
A304562 Construction Schedule (−40…+80 °C)
A304562 Type A (Standard Lift)3 × 10 mm² HV + 6×2×1.0 + 12F FIMTClass 5 tinned Cu + 316L FIMT25.41,680320.0380
A304562 Type B (Heavy Work-Class)3 × 16 mm² HV + 8×2×1.0 + 12F FIMTClass 5 tinned Cu + 316L FIMT32.22,650480.0485
A304562 Type C (Ultra-Deep Trencher)3 × 25 mm² HV + 12×2×1.0 + 24F FIMTClass 5 tinned Cu + 316L FIMT38.13,890680.0570
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow)DC resistance at 20 °C / optical attenuation and outer diameter within SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow)Zero dielectric breakdown and verified insulation resistance for 3.6/6 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow)Verified submersion integrity, tensile load and thermal stability across −40…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

SAE AS81044 / ISO 13628-5 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX A304562 SAE AS81044 / ISO 13628-5 3.6/6 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define A304562 (A304562 Series 3.0–7.0 kV (845 kN) Steel-Armoured ROV & Plow Umbilical)?
A304562 (A304562 Series 3.0–7.0 kV (845 kN) Steel-Armoured ROV & Plow Umbilical) is manufactured in accordance with SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow for 3.6/6 kV service over -40 °C to +80 °C. Its 5-layer construction comprises optical package (7×smf), coaxial & signal cores (1 coax + 4 sig) and torque-balanced steel armour (845 kn).
What is the minimum bending radius and operating temperature range for A304562?
The minimum bending radius for A304562 is 15 × OD across its continuous operating temperature range of -40 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of A304562 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Optical Package (7×SMF) — Laser-welded stainless-steel tube / Stainless-Steel-Tube package for 6,000 m depth; (02) Coaxial & Signal Cores (1 Coax + 4 Sig) — 19-strand tinned copper + SAE AS81044 (SPEC 44) dual-wall irradiated insulation; (03) HV Power Conductors (20 Cores) — Stranded tinned copper with 3,000–7,000 V AC SPEC 44 / XLPE insulation; (04) Ground Tape, Overall Braid & Elastomer Belt — Water-blocked core + Cu/PET tape + tinned Cu braid + Elastomer inner sheath; (05) Torque-Balanced Steel Armour (845 kN) — Preformed contra-helical high-carbon galvanized steel wire armour.
What factory test certificates are supplied with A304562?
Every production drum of A304562 undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per SAE AS81044 (SPEC 44) / ISO 13628-5 Heavy-Lift ROV & Plow, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for A304562

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

A304562 Series 3.0–7.0 kV (845 kN) Steel-Armoured ROV & Plow Umbilical

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote