Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
A302799 (0.450" 40-Ohm) HDPE-Insulated Double-Armored Side-Scan Sonar & Oceanographic Coaxial Tow Cable (NOAA 0.450" Sonar Tow, 1.8/3 kV, -40 °C to +80 °C, min. bend radius 12 × OD).
Typical values for this cable type, based on NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow — confirmed in the datasheet and quotation for your order.
Application fit
A302799 (0.450" 40-Ohm) HDPE-Insulated Double-Armored Side-Scan Sonar & Oceanographic Coaxial Tow Cable (NOAA 0.450" Sonar Tow, 1.8/3 kV, -40 °C to +80 °C, min. bend radius 12 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: A302799 (NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow) featuring center conductor (14 awg bare cu), 40 ω hdpe coaxial dielectric and double gips steel armor (24 + 24 wires) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Center Conductor (14 AWG Bare Cu) | Stranded bare copper center conductor (Ø 1.73 mm, DCR 9.8 Ω/km) |
| 2 | 40 Ω HDPE Coaxial Dielectric | Solid high-density polyethylene insulation (Ø 4.52 mm, 1,900 VDC, 131 pF/m) |
| 3 | Served Cu Return & Cu/PET Tape | 12 AWG equiv. served bare copper wires (Ø 5.16 mm) + copper-polyester tape |
| 4 | HDPE Inner Belt Jacket (Ø 7.29 mm) | Extruded high-density polyethylene barrier protecting return conductor |
| 5 | Double GIPS Steel Armor (24 + 24 Wires) | Inner 24×0.95 mm + outer 24×1.22 mm contra-helical GIPS wires (71.2 kN MBL) |
Built to NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow with center conductor (14 awg bare cu) and double gips steel armor (24 + 24 wires)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| A302799 Construction Schedule (−40…+80 °C) | |||||||
| A302799 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| A302799 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| A302799 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 1.8/3 kV (45–100 Ω data) | −40…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 1.8/3 kV (45–100 Ω data) | −40…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 1.8/3 kV (High-Power Hybrid) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow) | DC resistance at 20 °C / optical attenuation and outer diameter within NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (NOAA Standard 0.450" (11.43 mm) 40 Ω Side-Scan Sonar Tow) | Verified submersion integrity, tensile load and thermal stability across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.