7110W 600V TC-ER / 1000V WTTC Robotics Control CableUL 1277 TC-ER 600 V / UL 2277 WTTC 1,000 V (-40 to +90 °C) Class K fine-stranded continuous-flex control cable for robotic cells, drag chains and wind turbines.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Anti-torsion braid
Oil-resistant
Flame-retardant
Outdoor & humid
Order designation
7110W 18 AWG 5C (4C + G/Y)
Outer diameter
8.6 mm
Cable weight
108 kg/km
Min. bend radius
69 mm
Conductor & shield
41×34 AWG Class K Bare Cu + PVC/Nylon
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600/1,000 V
UL 1277 TC-ER / UL 2277 WTTC
Temperature
−40…+90 °C
Fixed / flex duty
Min. bend radius
8 × OD
8.6–17.8 mm
Screening
Unshielded
Continuous-flex & ±360°/m torsion
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per UL 1277 TC-ER / UL 2277 WTTC (7110W 600V TC-ER / 1000V WTTC) — confirmed in the datasheet and quotation for your order.

Application fit

Is 7110W 600V TC-ER / 1000V WTTC right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for open cable tray, raceway and supported industrial runs per standard installation rules.

Motor stator, traction & converter leads

Suitable

Fine-stranded copper conductors withstand routine equipment vibration and occasional flexing.

Energy chain / drag chain

Suitable

Fine-stranded copper cores and low-friction cabling support multi-million-cycle linear carrier travel.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Wind turbine tower & nacelle

Suitable

Cold-flex and torsion-tested 000 V construction supports wind turbine tower risers, yaw loops, and nacelle switchgear.

Typical machinesIndustrial Automation CableIndustrial automation & control cabinetsInverter-fed motor drive systemsProcess instrumentation & oil/gas skidsMachine tools & robotic cellsData centers, stadiums & broadcast facilities

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

7110W 600V TC-ER / 1000V WTTC – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Fine-Stranded Bare Copper Conductors18 AWG (41×34) Class K High-Flex Bare Copper
2Lubricated PVC/Nylon Core InsulationBlack Numbered Cores + 1 Green/Yellow Ground
3Low-Friction Non-Woven Wrap TapeTorsion & Continuous-Flex Slip Separator Tape
4Oil-Resistant Black PVC Outer JacketUL 1277 TC-ER / WTTC Sunlight & Oil Resistant Sheath

5G18 AWG (5 × 0.82 mm²)

41×34 AWG Class K Bare Cu + PVC/Nylon · Outer diameter 8.6 mm.

12G18 AWG (12 × 0.82 mm²)

41×34 AWG Class K Bare Cu + PVC/Nylon · Outer diameter 12.7 mm.

25G18 AWG (25 × 0.82 mm²)

41×34 AWG Class K Bare Cu + PVC/Nylon · Outer diameter 17.8 mm.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per UL 1277 TC-ER / UL 2277 WTTC (7110W 600V TC-ER / 1000V WTTC). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
600 V TC-ER / 1,000 V WTTC
Conductor & core insulation
18 AWG (41×34) Class K High-Flex Bare Copper · Black Numbered Cores + 1 Green/Yellow Ground
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
−40…+90 °C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
UL 1277 TC-ER / UL 2277 WTTC

Mechanical

Minimum bending radius
8 × OD
Screening / armour architecture
Unshielded multi-core construction · mechanical protection via outer jacket
Outer sheath material & colour
UL 1277 TC-ER / WTTC Sunlight & Oil Resistant Sheath

Reference standards

Reference standard
UL 1277 TC-ER / UL 2277 WTTC / UL AWM 2587 / CSA C22.2 No. 210 / NFPA 79
Hazardous Substance Compliance
CE, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
7110W 600V TC-ER / 1000V WTTC
5G18 AWG (5 × 0.82 mm²)41×34 AWG Class K Bare Cu + PVC/NylonBlack Numbered Cores + 1 Green/Yellow GroundIndustrial PVC8.66921.4039.4108600 V TC-ER / 1,000 V WTTC (10 A)7110W 18 AWG 5C (4C + G/Y)
12G18 AWG (12 × 0.82 mm²)41×34 AWG Class K Bare Cu + PVC/NylonBlack Numbered Cores + 1 Green/Yellow GroundIndustrial PVC12.710221.4094.5232600 V TC-ER / 1,000 V WTTC (7 A)7110W 18 AWG 12C (11C + G/Y)
25G18 AWG (25 × 0.82 mm²)41×34 AWG Class K Bare Cu + PVC/NylonBlack Numbered Cores + 1 Green/Yellow GroundIndustrial PVC17.814221.40196.8455600 V TC-ER / 1,000 V WTTC (5 A)7110W 18 AWG 25C (24C + G/Y)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °CEvery manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation or shieldEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing within standard char limitType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 1277 TC-ER / UL 2277 WTTC CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 7110W 600V TC-ER / 1000V WTTC UL 1277 TC-ER / UL 2277 WTTC 600 V TC-ER / 1,000 V WTTC CE ROHS — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
305 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-03
Updated
2026-11-03

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is 7110W 600V TC-ER / 1000V WTTC designed for?
7110W 600V TC-ER / 1000V WTTC is engineered for industrial installations under UL 1277 TC-ER / UL 2277 WTTC, operating over −40…+90 °C with a minimum bending radius of 8 × OD.
How does the construction of 7110W 600V TC-ER / 1000V WTTC protect signal and power integrity?
Its multi-layer build combines Fine-Stranded Bare Copper Conductors with Lubricated PVC/Nylon Core Insulation and Oil-Resistant Black PVC Outer Jacket to ensure mechanical stability and electrical performance.
What standards and fire ratings apply to 7110W 600V TC-ER / 1000V WTTC?
The cable is qualified to UL 1277 TC-ER / UL 2277 WTTC / UL AWM 2587 / CSA C22.2 No. 210 / NFPA 79, meeting vertical flame propagation and industrial jacket durability requirements.
Can 7110W 600V TC-ER / 1000V WTTC be supplied in custom lengths or configurations?
Yes. Standard configurations include 7110W 18 AWG 5C (4C + G/Y), 7110W 18 AWG 12C (11C + G/Y) and 7110W 18 AWG 25C (24C + G/Y), supplied on 305 m, 500 m or 1,000 m export drums.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 7110W 600V TC-ER / 1000V WTTC

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

7110W 600V TC-ER / 1000V WTTC Robotics Control Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote