Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
6XM524, 4XM525, 6XM551 & 4XM550 HDPE-Insulated Individually Shielded Communication Pairs & Power Aramid-Reinforced (320–960 kg) PUR Underwater Cable (IEC 60228 / Subsea IS, 600 V, -30 °C to +80 °C, min. bend radius 10 × OD).
Typical values for this cable type, based on IEC 60228 / Subsea Individually Shielded Pair Standard — confirmed in the datasheet and quotation for your order.
Application fit
6XM524, 4XM525, 6XM551 & 4XM550 HDPE-Insulated Individually Shielded Communication Pairs & Power Aramid-Reinforced (320–960 kg) PUR Underwater Cable (IEC 60228 / Subsea IS, 600 V, -30 °C to +80 °C, min. bend radius 10 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 6XM524 / 4XM525 / 6XM551 / 4XM550 (IEC 60228 / Subsea Individually Shielded Pair Standard) featuring individually shielded pairs (2×2×24 awg is), power conductors (2×16 awg / 2×18 awg) and subsea polyurethane jacket (ø8.8–11.0 mm) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Individually Shielded Pairs (2×2×24 AWG IS) | HDPE-insulated twisted pairs with individual Al/PET foil & drain wire (or 2×2×0.50 mm²) |
| 2 | Power Conductors (2×16 AWG / 2×18 AWG) | Two stranded tinned copper power conductors with high-density polyethylene insulation |
| 3 | Aramid Braided Strength Member (320–960 kg) | 320 kg (4XM525 / 6XM524) or 960 kg (6XM551 / 4XM550) synthetic fiber tensile braid |
| 4 | Subsea Polyurethane Jacket (Ø8.8–11.0 mm) | Black hydrolysis- and abrasion-resistant marine polyurethane (PUR) outer sheath |
Built to IEC 60228 / Subsea Individually Shielded Pair Standard with individually shielded pairs (2×2×24 awg is) and subsea polyurethane jacket (ø8.8–11.0 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60228 / Subsea Individually Shielded Pair Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 6XM524 / 4XM525 / 6XM551 / 4XM550 Construction Schedule (−30…+80 °C) | |||||||
| 6XM524 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| 6XM524 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| 6XM524 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60228 / Subsea Individually Shielded Pair Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60228 / Subsea Individually Shielded Pair Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60228 / Subsea Individually Shielded Pair Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60228 / Subsea Individually Shielded Pair Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.