Energy chain / drag chain
Extra-flexible 0.6/1 kV PP/PUR stranding and 7.5×D bend rating endure continuous energy-chain flexing.
Product
5230 SK-C PUR 0.6/1 kV integrates Class 6 bare copper conductors, low-capacitance PP insulation, shielded brake pairs, ≥ 85% tinned copper braid, and a wear-resistant DESINA orange PUR sheath for high-speed handling axes.
Typical values for this cable type, based on DIN VDE 0250 · UL AWM Style 21223 · CSA AWM I/II A/B FT1 — confirmed in the datasheet and quotation for your order.
Application fit
5230 SK-C PUR 0.6/1 kV integrates Class 6 bare copper conductors, low-capacitance PP insulation, shielded brake pairs, ≥ 85% tinned copper braid, and a wear-resistant DESINA orange PUR sheath for high-speed handling axes.
Extra-flexible 0.6/1 kV PP/PUR stranding and 7.5×D bend rating endure continuous energy-chain flexing.
Balanced 0.6/1 kV PP/PUR geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.
Flexible oil-resistant 0.6/1 kV PP/PUR construction routes cleanly along factory automation trays, machine frames, and production lines.
Multi-axis torsion-capable 0.6/1 kV PP/PUR stranding handles continuous robotic dress-pack twisting and automated assembly cells.
0.6/1 kV PP/PUR build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-J0.6/1 kV PP/PUR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of 5230 SK-C PUR 0.6/1 kV: bare copper conductors, Low-capacitance polypropylene (PP), Individually shielded brake pair + overall ≥ 85% tinned Cu braid, and DESINA orange (RAL 2003) matte halogen-free PUR sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 flexible bare annealed copperIEC 60228 Class 5 |
| 2 | Core insulation | Low-capacitance polypropylene (PP)DIN VDE 0250 |
| 3 | Core assembly & separator | Concentric cabled assembly with low-friction fleece or polyester binder tapeDIN VDE 0250 |
| 4 | EMC metallic screen | Individually shielded brake pair + overall ≥ 85% tinned Cu braidEMC ≥ 85% / 100% foil |
| 5 | Outer sheath | DESINA orange (RAL 2003) matte halogen-free PUR sheathIEC 60332-1-2 Flame |
Colour-coded or numbered phase conductors with protective green/yellow earth under overall EMC screening.
Technical data
Sizes
| Power + Brake mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 7.5×D mm |
|---|---|---|---|---|---|
| 4G1.5 + 2×1 | 13.2 | 13.300 | 112 | 255 | 99 |
| 4G2.5 + 2×1 | 14.3 | 7.980 | 152 | 325 | 107 |
| 4G4 + 2×1.5 | 15.6 | 4.950 | 220 | 437 | 117 |
| 4G6 + 2×1.5 | 17.0 | 3.300 | 297 | 565 | 128 |
| 4G10 + 2×1.5 | 20.3 | 1.910 | 452 | 842 | 152 |
| 4G16 + 2×1.5 | 23.9 | 1.210 | 681 | 1,237 | 179 |
| 4G25 + 2×1.5 | 27.1 | 0.780 | 1,019 | 1,774 | 203 |
| 4G35 + 2×1.5 | 31.0 | 0.554 | 1,394 | 2,399 | 232 |
| 4G50 + 2×1.5 | 34.6 | 0.386 | 1,951 | 3,263 | 260 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 4 kV AC for 5 min without breakdown | Every manufactured drum |
| Conductor DC resistance test | Per IEC 60228 at 20 °C | Every drum length |
| Sample tests | ||
| EMC screen coverage & insulation check | ≥ 85% TCWB continuity & wall thickness | Per production lot |
| Flame & environmental qualification | IEC 60332-1-2 Flame · EN 60811-404 Oil | Type approval |
Marking & supply
Sheath marking
Technical documents