Order designation
108 PVC / 6FX5008 0.6/1 kV 4G6
Outer Ø
15.5 mm
Max. R20
3.300 Ω/km
Weight
478 kg/km
Min. bend R
155 mm
All sizes (9)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
AC test voltage 4 kV AC
EMC screening
Foil + TCWB
Low transfer impedance EMC shield
Temp. (fixed)
-40°C…+80°C
Flexing: -5 °C to +70 °C
Min. bend radius
10 × OD
Fixed routing in trays & ducts
Conductor
Bare Cu · Cl.5
IEC 60228 stranded copper
Size range
4G1.5–4G50
9 standard configurations

Typical values for this cable type, based on DIN VDE 0250 · UL AWM Style 2570 · IEC 60228 Class 5 — confirmed in the datasheet and quotation for your order.

Application fit

Is 108 PVC / 6FX5008 0.6/1 kV right for your machine?

108 PVC (6FX5008) 0.6/1 kV provides Class 5 bare copper conductors, low-capacitance PP insulation, ≥ 85% tinned copper braid, and a DESINA orange PVC sheath engineered for stationary servo motor power feeds.

Motor stator, traction & converter leads

Suitable

Balanced 0.6/1 kV PP/PVC geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.

Fixed installation

Suitable

Durable 0.6/1 kV PP/PVC outer sheath handles stationary routing along trays, machine beds, conduits, and plant racks.

Factory automation tray & machine bus

Suitable

Flexible oil-resistant 0.6/1 kV PP/PVC construction routes cleanly along factory automation trays, machine frames, and production lines.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 0.6/1 kV PP/PVC geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Energy chain / drag chain

Not suitable

0.6/1 kV PP/PVC construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

0.6/1 kV PP/PVC outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial Automation CableAutomated assembly & handling linesCNC machine tools & gantry axesPackaging, robotics & intralogisticsFactory servo drive & motion bays

Construction

Layer by layer

Representative construction of 108 PVC / 6FX5008 0.6/1 kV: bare copper conductors, Low-capacitance polypropylene (PP), Foil separator + ≥ 85% tinned copper braid shield, and DESINA orange (RAL 2003) flame-retardant PVC sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 5 flexible bare annealed copperIEC 60228 Class 5
2Core insulationLow-capacitance polypropylene (PP)DIN VDE 0250
3Core assembly & separatorConcentric cabled assembly with low-friction fleece or polyester binder tapeDIN VDE 0250
4EMC metallic screenFoil separator + ≥ 85% tinned copper braid shieldEMC ≥ 85% / 100% foil
5Outer sheathDESINA orange (RAL 2003) flame-retardant PVC sheathIEC 60332-1-2 Flame

108 PVC / 6FX5008 0.6/1 kV Power & Ground

Colour-coded or numbered phase conductors with protective green/yellow earth under overall EMC screening.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250 · UL AWM Style 2570 · IEC 60228 Class 5. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
0.6/1 kV
AC test voltage
4 kV AC / 5 min
Conductor class
IEC 60228 Class 5 bare Cu
EMC screen
Foil separator + ≥ 85% tinned copper
Insulation resistance
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-40 °C to +80 °C
Temp. range (flexing)
-5 °C to +70 °C
Short-circuit temp.
+160 °C (5 s)
Min. bending radius
10 × OD (fixed)

Resistance

Flame retardance
IEC 60332-1-2 Flame
Oil & chemical perf.
UL VW-1 / CSA FT1
Environmental / EMC
Oil Resistant PVC
Outer sheath
DESINA orange (RAL 2003) flame-retardant

Sizes

4-Core Screened (mm²)
Cores ×
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
10×D mm
4G1.511.613.30084191116
4G2.512.87.980123259128
4G414.14.950181355141
4G615.53.300257478155
4G1018.71.910411743187
4G1622.41.2106381,128224
4G2525.50.7809741,650255
4G3529.40.5541,3482,261294
4G5033.10.3861,9033,115331
  • Max. conductor DC resistance R20 at 20 °C per IEC 60228 (bare copper).
  • Minimum bending radius calculated at 10 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage dielectric test4 kV AC for 5 min without breakdownEvery manufactured drum
Conductor DC resistance testPer IEC 60228 at 20 °CEvery drum length
Sample tests
EMC screen coverage & insulation checkFoil + TCWB continuity & wall thicknessPer production lot
Flame & environmental qualificationIEC 60332-1-2 Flame · UL VW-1 / CSA FT1Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250UL AWM Style 2570IEC 60228 Class 5EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

108 PVC / 6FX5008 0.6/1 kV 0.6/1 kV TEBAOFLEX.COM [DIN VDE 0250] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export drums
Standard drum lengths
500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-21
Updated
2026-11-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes 108 PVC / 6FX5008 0.6/1 kV suitable for 0.6/1 kV industrial installations?
108 PVC / 6FX5008 0.6/1 kV combines bare copper conductors, Low-capacitance polypropylene (PP), and Foil separator + ≥ 85% tinned copper braid shield inside a DESINA orange (RAL 2003) flame-retardant PVC sheath. Standard DESINA orange PVC construction for stationary drive-to-motor machine connections.
Can 108 PVC / 6FX5008 0.6/1 kV operate inside continuous drag chains or moving axes?
No. 108 PVC / 6FX5008 0.6/1 kV is engineered for stationary tray, conduit, or machine-frame routing at 10 × OD minimum bending radius; choose a PUR drag-chain cable for continuous flexing.
How should the EMC shield of 108 PVC / 6FX5008 0.6/1 kV be grounded at termination?
Bond the metallic screen circumferentially (360°) at both drive and motor ends using EMC cable glands or low-impedance shielding clamps to minimize high-frequency transfer impedance.
What standards, drum lengths, and test certificates accompany 108 PVC / 6FX5008 0.6/1 kV?
108 PVC / 6FX5008 0.6/1 kV conforms to DIN VDE 0250, UL AWM Style 2570, IEC 60228 Class 5 (IEC 60332-1-2 Flame) and ships cut-to-length or on export drums with an EN 10204 3.1 routine test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 108 PVC / 6FX5008 0.6/1 kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

108 PVC (6FX5008) 0.6/1 kV Servo Motor Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote