Immersion & wet locations
Longitudinal water-blocking compounds and high-pressure subsea PUR/PE jackets survive up to 600 bar (6,000 m) hydrostatic immersion.
Product
Water-Blocking Direct Burial RS-485 Data Cable featuring stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath (TIA/EIA-485 / IEC 60529 AD8, 300 V, -40 to +80 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard — confirmed in the datasheet and quotation for your order.
Application fit
Water-Blocking Direct Burial RS-485 Data Cable featuring stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath (TIA/EIA-485 / IEC 60529 AD8, 300 V, -40 to +80 °C, min. bend radius 8 × OD).
Longitudinal water-blocking compounds and high-pressure subsea PUR/PE jackets survive up to 600 bar (6,000 m) hydrostatic immersion.
Controlled 100 Ω Ethernet, 120 Ω RS-485 and 50/75 Ω coaxial impedance ensures low-attenuation telemetry across subsea arrays.
Stranded tinned copper conductors and braided shields tolerate ROV tether flexing, buoy moorings and subsea frame routing.
NEK 606 MUD-resistant LSHF and UV-stabilized PUR jackets withstand offshore topside trays and wet deck splash zones.
Unarmoured sensor bus and coax cables require strain relief and are not intended for unguided high-tension crane drums.
Use 1SSA13 Armoured Coax TowConstruction
Shown: Water-Blocking RS-485 Direct Burial (TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard) featuring stranded copper twisted pairs (2×2), 100% al/pet foil electrostatic shield and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Twisted Pairs (2×2) | Twisted pairs with Low-capacitance cellular Foam-Skin PE insulation |
| 2 | 100% Al/PET Foil Electrostatic Shield | Laminated aluminum-polyester foil tape with drain wire |
| 3 | Subsea / Marine Outer Protective Sheath | Black high-density polyethylene (HDPE) waterproof outer sheath |
Built to TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard with stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Water-Blocking RS-485 Direct Burial Construction Schedule (−40…+80 °C) | |||||||
| Water-Blocking RS-485 Direct Burial 1×2×22AWG RS | 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | Stranded SnCu + Foam PE + Foil/Braid | 8.2 | 92 | 2.0 | 50 | |
| Water-Blocking RS-485 Direct Burial 4×2×24AWG Ca | 4 × 2 × 24 AWG Subsea Gigabit Ethernet | Stranded SnCu + High-Pressure PE + SF/UTP | 9.6 | 125 | 3.5 | 60 | |
| Water-Blocking RS-485 Direct Burial 4×2×23AWG Ca | 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | Stranded SnCu + 600-Bar Matrix + PUR | 12.8 | 215 | 6.8 | 78 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | 55.00 | 300 V (120 Ω RS-485) | −40…+80 °C |
| 4 × 2 × 24 AWG Subsea Gigabit Ethernet | 84.00 | 300 V (100 Ω 1000BASE-T) | −40…+80 °C |
| 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | 72.00 | 300 V (100 Ω Cat6 6000m) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard) | Zero dielectric breakdown and verified wet insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (TIA/EIA-485 Water-Blocking Direct-Burial & Submersible RS-485 Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.