Immersion & wet locations
Longitudinal water-blocking compounds and high-pressure subsea PUR/PE jackets survive up to 600 bar (6,000 m) hydrostatic immersion.
Product
Tactical Aramid Camera & Crawler Data Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (ISO/IEC 11801 / MIL-DTL-24643, 300 V, -40 to +85 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard — confirmed in the datasheet and quotation for your order.
Application fit
Tactical Aramid Camera & Crawler Data Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (ISO/IEC 11801 / MIL-DTL-24643, 300 V, -40 to +85 °C, min. bend radius 6 × OD).
Longitudinal water-blocking compounds and high-pressure subsea PUR/PE jackets survive up to 600 bar (6,000 m) hydrostatic immersion.
Controlled 100 Ω Ethernet, 120 Ω RS-485 and 50/75 Ω coaxial impedance ensures low-attenuation telemetry across subsea arrays.
Stranded tinned copper conductors and braided shields tolerate ROV tether flexing, buoy moorings and subsea frame routing.
NEK 606 MUD-resistant LSHF and UV-stabilized PUR jackets withstand offshore topside trays and wet deck splash zones.
Unarmoured sensor bus and coax cables require strain relief and are not intended for unguided high-tension crane drums.
Use 1SSA13 Armoured Coax TowConstruction
Shown: Tactical Aramid Crawler Data Cable (ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard) featuring stranded copper twisted pairs (4×2), copper wire braid emc screen and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Twisted Pairs (4×2) | Twisted pairs with Fluoropolymer (FEP/ETFE) high-dielectric insulation |
| 2 | Copper Wire Braid EMC Screen | High-coverage braided copper shield for EMI/VFD protection |
| 3 | Aramid / LCP Braided Strength Member | High-tenacity synthetic fiber braid absorbing dynamic tension |
| 4 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard with stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Tactical Aramid Crawler Data Cable Construction Schedule (−40…+85 °C) | |||||||
| Tactical Aramid Crawler Data Cable 2×2×0.50 mm² | 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | Stranded SnCu + Foil/TCWB + Subsea PUR | 8.4 | 98 | 2.5 | 50 | |
| Tactical Aramid Crawler Data Cable 4×2×0.50 + 2× | 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | Stranded SnCu + Individual/Overall Shield | 11.8 | 195 | 5.2 | 70 | |
| Tactical Aramid Crawler Data Cable 4×2×0.75 + 4× | 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | Stranded SnCu + Aramid/Armour + PUR | 15.2 | 360 | 12.0 | 95 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | 39.00 | 300 V (4–20 mA / DO) | −40…+85 °C |
| 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | 39.00 | 300 V (CTD / Multi-Sensor) | −40…+85 °C |
| 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | 26.00 | 300 V (ROV / Camera / LED) | −40…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard) | Zero dielectric breakdown and verified wet insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (ISO/IEC 11801 Tactical Aramid Camera & Subsea Crawler Data Cable Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.