VFD inverter to AC motor screened feeder
100% aluminum/PET foil plus tinned copper braid shield contains PWM inverter common-mode currents and protects nearby water-quality sensor
Product
Washdown ECOLAB Seafood Washdown VFD Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (UL 1277 / ECOLAB / NSF, 600/1,000 V, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification — confirmed in the datasheet and quotation for your order.
Application fit
Washdown ECOLAB Seafood Washdown VFD Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (UL 1277 / ECOLAB / NSF, 600/1,000 V, -40 to +90 °C, min. bend radius 6 × OD).
100% aluminum/PET foil plus tinned copper braid shield contains PWM inverter common-mode currents and protects nearby water-quality sensor
Low-capacitance XLPE or EPR core insulation limits dV/dt reflected-wave voltage spikes on long submersible pump and aerator motor leads.
AD8 submersible EPDM, TPE and ECOLAB-certified jackets resist continuous water immersion, hypochlorite sanitizers and caustic washdown.
Routes through pump caissons, coastal intake stations, hatchery pipe galleries and stainless-steel seafood processing trays.
Submersible VFD motor supply cable is not designed as a self-supporting deepwater ROV lift umbilical.
Use RM0037 ROV Lift UmbilicalConstruction
Shown: Washdown ECOLAB VFD Cable (UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification) featuring flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (4 C | Class 5/ class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | Cross-linked polyethylene (xlpe) insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black chemical- & bio-oil-resistant thermoplastic elastomer (TPE) outer sheath |
Built to UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification with flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Washdown ECOLAB VFD Cable Construction Schedule (−40…+90 °C) | |||||||
| Washdown ECOLAB VFD Cable 4G4 / 3×4+3G0.75 | 4G4.0 mm² (or 3×4+3G0.75 + 2×1.0) | IEC 60228 Class 5 Cu + Foil/TCWB Shield | 14.6 | 365 | 3.8 | 90 | |
| Washdown ECOLAB VFD Cable 4G16 / 3×16+3G2.5 | 4G16 mm² (or 3×16+3G2.5 + 2×1.5) | IEC 60228 Class 5 Cu + Foil/TCWB Shield | 21.8 | 860 | 9.6 | 135 | |
| Washdown ECOLAB VFD Cable 4G50 / 3×50+3G10 | 4G50 mm² (or 3×50+3G10 mm² VFD) | IEC 60228 Class 5 Cu + Dual EMC Shield | 31.6 | 2,190 | 24.0 | 190 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G4.0 mm² (or 3×4+3G0.75 + 2×1.0) | 4.95 | 600/1,000 V (34 A Subsea VFD) | −40…+90 °C |
| 4G16 mm² (or 3×16+3G2.5 + 2×1.5) | 1.21 | 600/1,000 V (98 A Subsea VFD) | −40…+90 °C |
| 4G50 mm² (or 3×50+3G10 mm² VFD) | 0.39 | 600/1,000 V (195 A Subsea VFD) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification) | Zero dielectric breakdown and verified wet insulation resistance for 600/1,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (UL 1277 & ECOLAB Certified Seafood Processing Washdown VFD Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.