Contact
EMC-shielded submersible pump & washdown VFD cableIEC 60502-1 / UL 12770.6/1 kV (-40 to +90 °C)Subsea / Marine Outer Protective She

TF-VFD 650 Motor Power & Control Pair CableIEC 60502-1 / UL 1277 — 0.6/1 kV — -40 to +90 °C Subsea & Marine Cable

TF-VFD 650 Motor Power & Control Pair Cable featuring power supply conductors (4 cores) and subsea / marine outer protective sheath (IEC 60502-1 / UL 1277, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Water-resistant
EMC screen
Outdoor & humid
Approved
Order designation
TF-VFD 650 Hybrid 4G4 / 3×4+3G0.75
Outer Ø ≈
14.6 mm
Net weight ≈
365 kg/km
Max. pulling ≈
3.8 kN
Core / stranding
IEC 60228 Class 5 Cu + Foil/TCWB Shield
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60502-1 / UL 1277
Operating temp.
−40…+90 °C
Subsea, deck & cold-water duty
Min. bend radius
6 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Power Supply Con
Stranded copper power cores with Cross-l
Outer protection
Subsea / Marine
Black heavy-duty submersible elastomeric
Standard
IEC 60502-1 / UL
IEC 60502-1 & UL 1277 Hybrid VFD Power &

Typical values for this cable type, based on IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is TF-VFD 650 Hybrid right for your machine?

TF-VFD 650 Motor Power & Control Pair Cable featuring power supply conductors (4 cores) and subsea / marine outer protective sheath (IEC 60502-1 / UL 1277, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

VFD inverter to AC motor screened feeder

Suitable

100% aluminum/PET foil plus tinned copper braid shield contains PWM inverter common-mode currents and protects nearby water-quality sensor

Motor stator, traction & converter leads

Suitable

Low-capacitance XLPE or EPR core insulation limits dV/dt reflected-wave voltage spikes on long submersible pump and aerator motor leads.

Immersion & wet locations

Suitable

AD8 submersible EPDM, TPE and ECOLAB-certified jackets resist continuous water immersion, hypochlorite sanitizers and caustic washdown.

Fixed installation

Suitable

Routes through pump caissons, coastal intake stations, hatchery pipe galleries and stainless-steel seafood processing trays.

Vertical / spreader reel

Not suitable

Submersible VFD motor supply cable is not designed as a self-supporting deepwater ROV lift umbilical.

Use RM0037 ROV Lift Umbilical
Typical machinesMarine & Offshore CableVariable-Speed Submersible Aquaculture & Well PumpsRecirculating Aquaculture System (RAS) Circulation DrivesECOLAB / IP69K Seafood Processing Conveyor & Mixer VFDsOffshore Seawater Intake & Desalination Booster Pumps

Construction

Layer by layer

Shown: TF-VFD 650 Hybrid (IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification) featuring power supply conductors (4 cores), shielded data twisted pairs (4×2) and subsea / marine outer protective sheath (3-layer construction).

TF-VFD 650 Hybrid — stepped horizontal cutaway showing Power Supply Conductors (4 Cores) and Subsea / Marine Outer Pro
Layer cutaway
#LayerMaterial & reference
1Power Supply Conductors (4 Cores)Stranded copper power cores with Cross-linked polyethylene (XLPE) insulation
2Shielded Data Twisted Pairs (4×2)Impedance-controlled twisted pairs for Ethernet / RS-485 / DMX
3Subsea / Marine Outer Protective SheathBlack heavy-duty submersible elastomeric outer sheath

TF-VFD 650 Hybrid — Standard Subsea & Marine Execution

Built to IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification with power supply conductors (4 cores) and subsea / marine outer protective sheath

TF-VFD 650 Hybrid — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

TF-VFD 650 Hybrid — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
0.6/1 kV (IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification)
Core / conductor construction
Power Supply Conductors (4 Cores) — Stranded copper power cores with Cross-linked polyethylene (XLPE) insulation
Primary dielectric / optical buffer
Shielded Data Twisted Pairs (4×2) — Impedance-controlled twisted pairs for Ethernet / RS-485 / DMX

Thermal

Continuous operating temperature
−40…+90 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+90 °C per IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black heavy-duty submersible elastomeric outer sheath
Minimum bending radius
6 × OD
Reinforcement / screen / bedding layer
Shielded Data Twisted Pairs (4×2) — Impedance-controlled twisted pairs for Ethernet / RS-485 / DMX

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TF-VFD 650 Hybrid
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard TF-VFD 650 Hybrid configurations

Manufactured to IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
TF-VFD 650 Hybrid Construction Schedule (−40…+90 °C)
TF-VFD 650 Hybrid 4G4 / 3×4+3G0.754G4.0 mm² (or 3×4+3G0.75 + 2×1.0)IEC 60228 Class 5 Cu + Foil/TCWB Shield14.63653.890
TF-VFD 650 Hybrid 4G16 / 3×16+3G2.54G16 mm² (or 3×16+3G2.5 + 2×1.5)IEC 60228 Class 5 Cu + Foil/TCWB Shield21.88609.6135
TF-VFD 650 Hybrid 4G50 / 3×50+3G104G50 mm² (or 3×50+3G10 mm² VFD)IEC 60228 Class 5 Cu + Dual EMC Shield31.62,19024.0190
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification)DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification)Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 / UL 1277 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TF-VFD 650 Hybrid IEC 60502-1 / UL 1277 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define TF-VFD 650 Hybrid (TF-VFD 650 Motor Power & Control Pair Cable)?
TF-VFD 650 Hybrid (TF-VFD 650 Motor Power & Control Pair Cable) is manufactured in accordance with IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification for 0.6/1 kV subsea,ROV and marine aquaculture service over -40 to +90 °C. Its 3-layer construction comprises power supply conductors (4 cores), shielded data twisted pairs (4×2) and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for TF-VFD 650 Hybrid?
The minimum bending radius for TF-VFD 650 Hybrid is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of TF-VFD 650 Hybrid arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Power Supply Conductors (4 Cores) — Stranded copper power cores with Cross-linked polyethylene (XLPE) insulation; (02) Shielded Data Twisted Pairs (4×2) — Impedance-controlled twisted pairs for Ethernet / RS-485 / DMX; (03) Subsea / Marine Outer Protective Sheath — Black heavy-duty submersible elastomeric outer sheath.
What factory test certificates are supplied with TF-VFD 650 Hybrid?
Every production drum of TF-VFD 650 Hybrid undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per IEC 60502-1 & UL 1277 Hybrid VFD Power & Control Pair Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TF-VFD 650 Hybrid

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TF-VFD 650 Hybrid TF-VFD 650 Motor Power & Control Pair Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote