Contact
submarine & offshore armoured optical cableITU-T G.972 / URC-1 SubmarineOptical (-20 to +70 °C)MDPE / HDPE Insulating Outer Sheath

URC-1 Up to 96F Steel-Vault & Copper-Tube Deep-Sea Repeatered/Unrepeatered Submarine Optical CableITU-T G.972 / URC-1 Submarine — Optical — -20 to +70 °C Subsea & Offshore Cable

URC-1 Up to 96F Steel-Vault & Copper-Tube Deep-Sea Repeatered/Unrepeatered Submarine Optical Cable (ITU-T G.972 / URC-1 Submarine) engineered for Optical service across -20 to +70 °C (min. bend radius 20 × OD).

Water-resistant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
URC-1 Submarine FO 4–12F EOM/Sub
Outer Ø ≈
8.2 mm
Net weight ≈
260 kg/km
Tensile rating ≈
48.0 kN
Core / stranding
Laser-welded SS FIMT + Steel/Aramid Armour
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Optical
Tested per ITU-T G.972 / URC-1 Submarine
Operating temp.
−20…+70 °C
Continuous subsea & offshore service
Min. bend radius
20 × OD
Winch sheave, chute & seabed routing
Core / conductor
Central Stainles
Hermetically sealed stainless-steel tube
Outer protection
MDPE / HDPE Insu
High-density polyethylene outer jacket f
Standard
ITU-T G.972 / UR
ITU-T G.972 URC-1 Deep-Sea Steel-Vault &

Typical values for this cable type, based on ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is URC-1 Submarine FO right for your machine?

URC-1 Up to 96F Steel-Vault & Copper-Tube Deep-Sea Repeatered/Unrepeatered Submarine Optical Cable (ITU-T G.972 / URC-1 Submarine) engineered for Optical service across -20 to +70 °C (min. bend radius 20 × OD).

Fixed installation

Suitable

Laser-welded stainless-steel / copper-tube FIMT or water-blocked loose-tube construction protects ITU-T G.652D / G.654E / OM3/OM4 fibres.

Immersion & wet locations

Suitable

Hermetic metallic optical tube, steel vault and high-density PE/PUR serving withstand up to 8,000 m deep-ocean hydrostatic pressure.

Offshore platform & shipboard deck trays

Suitable

Galvanized steel or bronze wire armour and SHF2-MUD / PUR / PE jacket resist seabed abrasion, fishing-gear impact, oil and drilling mud.

Drilling jumbo & rotary mast feed

Suitable

NEK 606 QFCU and IEEE 1580 S670T executions maintain high-speed optical telemetry across hazardous offshore topside zones.

Energy chain / drag chain

Not suitable

Submarine and armoured offshore optical cable is not intended for indoor factory automation drag chains.

Use Deepwater ROV Optical Tether
Typical machinesUnderwater & Ocean ExplorationSubmarine Telecom & Cabled Ocean ObservatoriesIsland, Coastal & Inter-Platform Subsea Optical LinksOffshore Platform & FPSO Fire-Safe Optical BackbonesTactical Marine & Harsh-Environment Optical Deployment

Construction

Layer by layer

Shown: URC-1 Submarine FO (ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification) featuring central stainless-steel tube (up to 96×smf), galvanized steel arch-vault armour and mdpe / hdpe insulating outer sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central Stainless-Steel Tube (Up to 96×SHermetically sealed stainless-steel tube housing single-mode fibers
2Galvanized Steel Arch-Vault ArmourHigh-tensile interlocking galvanized steel wire pressure vault
3Continuous Copper Power Conductor TubeSwaged seamless copper tube for submarine power feeding
4MDPE / HDPE Insulating Outer SheathHigh-density polyethylene outer jacket for deep-sea deployment

URC-1 Submarine FO — Standard Subsea & Offshore Execution

Built to ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification with central stainless-steel tube (up to 96×smf) and mdpe / hdpe insulating outer sheath

URC-1 Submarine FO — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

URC-1 Submarine FO — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
Optical (ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification)
Core / conductor construction
Central Stainless-Steel Tube (Up to 96×SMF) — Hermetically sealed stainless-steel tube housing single-mode fibers
Primary dielectric / buffering
Galvanized Steel Arch-Vault Armour — High-tensile interlocking galvanized steel wire pressure vault

Thermal

Continuous operating temperature
−20…+70 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
MDPE / HDPE Insulating Outer Sheath — High-density polyethylene outer jacket for deep-sea deployment
Minimum bending radius
20 × OD
Armour, strength member & mechanical duty
Continuous Copper Power Conductor Tube — Swaged seamless copper tube for submarine power feeding

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
URC-1 Submarine FO
Sheath colour & metre marking
Continuous metre-marked black outer finish (MDPE / HDPE Insu)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard URC-1 Submarine FO subsea & offshore configurations

Manufactured to ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
URC-1 Submarine FO Construction Schedule (−20…+70 °C)
URC-1 Submarine FO 4–12F EOM/Sub4–12 × ITU-T G.652D / G.654E SM (+ Power)Laser-welded SS FIMT + Steel/Aramid Armour8.226048.0125
URC-1 Submarine FO 24–48F EOM/Sub24–48 × ITU-T G.652D / G.654E SM (+ Power)Laser-welded SS FIMT + Contra-Helical Steel17.5680120.0260
URC-1 Submarine FO 96–192F Trunk96–192 × ITU-T G.654E / G.652D SubmarineSS Tube + Steel Vault + Cu Tube + DA Armour28.01,650300.0420
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification)DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification)Zero dielectric breakdown and verified insulation resistance for Optical ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −20…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ITU-T G.972 / URC-1 Submarine CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX URC-1 Submarine FO ITU-T G.972 / URC-1 Submarine Optical CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define URC-1 Submarine FO (URC-1 Up to 96F Steel-Vault & Copper-Tube Deep-Sea Repeatered/Unrepeatered Submarine Optical Cable)?
URC-1 Submarine FO (URC-1 Up to 96F Steel-Vault & Copper-Tube Deep-Sea Repeatered/Unrepeatered Submarine Optical Cable) is manufactured in accordance with ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification for Optical service over -20 to +70 °C. Its 4-layer construction comprises central stainless-steel tube (up to 96×smf), galvanized steel arch-vault armour and mdpe / hdpe insulating outer sheath.
What is the minimum bending radius and operating temperature range for URC-1 Submarine FO?
The minimum bending radius for URC-1 Submarine FO is 20 × OD across its continuous operating temperature range of -20 to +70 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of URC-1 Submarine FO arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central Stainless-Steel Tube (Up to 96×SMF) — Hermetically sealed stainless-steel tube housing single-mode fibers; (02) Galvanized Steel Arch-Vault Armour — High-tensile interlocking galvanized steel wire pressure vault; (03) Continuous Copper Power Conductor Tube — Swaged seamless copper tube for submarine power feeding; (04) MDPE / HDPE Insulating Outer Sheath — High-density polyethylene outer jacket for deep-sea deployment.
What factory test certificates are supplied with URC-1 Submarine FO?
Every production drum of URC-1 Submarine FO undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per ITU-T G.972 URC-1 Deep-Sea Steel-Vault & Copper-Tube Submarine Fiber Optic Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for URC-1 Submarine FO

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

URC-1 Submarine FO URC-1 Up to 96F Steel-Vault & Copper-Tube Deep-Sea Repeatered/Unrepeatered Submarine Optical Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote