subsea ROV umbilical, AUV tether & sonar tow cableEN 13508 / IEC 60794600 V (-30 to +80 °C)Subsea / Marine Outer Protective She

Type 00/12/FO2 & 00/20/FOX2 Fiber Crawler CableEN 13508 / IEC 60794 — 600 V — -30 to +80 °C Subsea & Marine Cable

Type 00/12/FO2 & 00/20/FOX2 Fiber Crawler Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (EN 13508 / IEC 60794, 600 V, -30 to +80 °C, min. bend radius 6 × OD).

Water-resistant
Oil-resistant
Outdoor & humid
Approved
Order designation
Type 00 Hybrid 4G2.5+FO
Outer Ø ≈
14.6 mm
Net weight ≈
285 kg/km
Max. pulling ≈
18.0 kN
Core / stranding
Class 5 SnCu + Aramid Braid + Subsea PUR
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per EN 13508 / IEC 60794
Operating temp.
−30…+80 °C
Subsea, deck & cold-water duty
Min. bend radius
6 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Single-Mode / Mu
Hermetic stainless-steel tube / tight-bu
Outer protection
Subsea / Marine
Black hydrolysis- & abrasion-resistant m
Standard
EN 13508 / IEC 6
EN 13508 & IEC 60794 Type 00/12/FO2 & 00

Typical values for this cable type, based on EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is Type 00/12/FO2 & 00/20/FOX2 Crawler right for your machine?

Type 00/12/FO2 & 00/20/FOX2 Fiber Crawler Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (EN 13508 / IEC 60794, 600 V, -30 to +80 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant subsea PUR or HDPE outer sheath and water-blocked core interstices withstand continuous deep-ocean hydrostatic immers

Vertical / spreader reel

Suitable

Contra-helical galvanized steel wire armour or high-modulus aramid/LCP braid supports vertical traction winches, TMS cages and tow sheaves

Free-hanging vertical run

Suitable

Torque-balanced armour or neutrally buoyant foamed-PUR jacket prevents hockling and kinking during free-swimming ROV and tether excursions

Offshore platform & shipboard deck trays

Suitable

Resists seawater, marine bio-fouling, hydraulic oil, UV radiation and abrasion across vessel A-frames and launch-and-recovery systems (LAR

Energy chain / drag chain

Not suitable

Subsea ROV umbilicals and tow cables are optimized for winch deployment and water-column catenaries rather than high-speed factory drag ch

Use Drag-Chain Feeder Cable
Typical machinesUnderwater & Ocean ExplorationWork-Class & Observation ROV Umbilicals and TMS TethersOffshore Aquaculture Net Cleaners & Subsea Cage InspectionAUV, Ocean Glider & Expendable Spool-Payoff Micro-TethersUSV Towed Sonar Arrays, Seabed Crawlers & Subsea Trenchers

Construction

Layer by layer

Shown: Type 00/12/FO2 & 00/20/FOX2 Crawler (EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (3-layer construction).

Type 00/12/FO2 & 00/20/FOX2 Crawler — stepped horizontal cutaway showing Single-Mode / Multi-Mode Optical Unit and Sub
Layer cutaway
#LayerMaterial & reference
1Single-Mode / Multi-Mode Optical UnitHermetic stainless-steel tube / tight-buffered optical unit
2Power & Control Copper ConductorsStranded copper conductors with Fluoropolymer (FEP/ETFE) high-dielectric insulation
3Subsea / Marine Outer Protective SheathBlack hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath

Type 00/12/FO2 & 00/20/FOX2 Crawler — Standard Subsea & Marine Execution

Built to EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard with single-mode / multi-mode optical unit and subsea / marine outer protective sheath

Type 00/12/FO2 & 00/20/FOX2 Crawler — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

Type 00/12/FO2 & 00/20/FOX2 Crawler — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
600 V (EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard)
Core / conductor construction
Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit
Primary dielectric / optical buffer
Power & Control Copper Conductors — Stranded copper conductors with Fluoropolymer (FEP/ETFE) high-dielectric insulation

Thermal

Continuous operating temperature
−30…+80 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −30…+80 °C per EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath
Minimum bending radius
6 × OD
Reinforcement / screen / bedding layer
Power & Control Copper Conductors — Stranded copper conductors with Fluoropolymer (FEP/ETFE) high-dielectric insulation

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Type 00/12/FO2 & 00/20/FOX2 Crawler
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Type 00/12/FO2 & 00/20/FOX2 Crawler configurations

Manufactured to EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
Type 00/12/FO2 & 00/20/FOX2 Crawler Construction Schedule (−30…+80 °C)
Type 00 Hybrid 4G2.5+FO4G2.5 mm² Power + 4×SM + 2×2×0.5Class 5 SnCu + Aramid Braid + Subsea PUR14.628518.090
Type 00 Hybrid 4G6+FO4G6.0 mm² Power + 4×SM/MM + 4×2×0.5Class 5 SnCu + Aramid Braid + Subsea PUR19.254032.0120
Type 00 Hybrid 4G16+FO4G16 mm² Power + 8×SM/MM + 4×2×0.75Class 5 SnCu + Heavy Aramid + Subsea PUR26.51,12055.0165
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard)DC resistance at 20 °C, optical attenuation and wall thickness within EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard)Zero dielectric breakdown and verified wet insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard)Verified hydrostatic pressure integrity, breaking load and flex endurance across −30…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 13508 / IEC 60794 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Type 00/12/FO2 & 00/20/FOX2 Crawler EN 13508 / IEC 60794 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Type 00/12/FO2 & 00/20/FOX2 Crawler (Type 00/12/FO2 & 00/20/FOX2 Fiber Crawler Cable)?
Type 00/12/FO2 & 00/20/FOX2 Crawler (Type 00/12/FO2 & 00/20/FOX2 Fiber Crawler Cable) is manufactured in accordance with EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard for 600 V subsea,ROV and marine aquaculture service over -30 to +80 °C. Its 3-layer construction comprises single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for Type 00/12/FO2 & 00/20/FOX2 Crawler?
The minimum bending radius for Type 00/12/FO2 & 00/20/FOX2 Crawler is 6 × OD across its continuous operating temperature range of -30 to +80 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of Type 00/12/FO2 & 00/20/FOX2 Crawler arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit; (02) Power & Control Copper Conductors — Stranded copper conductors with Fluoropolymer (FEP/ETFE) high-dielectric insulation; (03) Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath.
What factory test certificates are supplied with Type 00/12/FO2 & 00/20/FOX2 Crawler?
Every production drum of Type 00/12/FO2 & 00/20/FOX2 Crawler undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per EN 13508 & IEC 60794 Type 00/12/FO2 & 00/20/FOX2 Fiber Pipeline Crawler Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Type 00/12/FO2 & 00/20/FOX2 Crawler

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Type 00/12/FO2 & 00/20/FOX2 Fiber Crawler Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote