Motorised monospiral reel
Integrated contra-helical aramid anti-torsion braid and high-tear-strength PUR/rubber sheath withstand continuous monospiral and level-win
Product
SMK-Reeling PUR Salvage Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (DIN VDE 0250-814 / DNV, 0.6/1 kV (1.8/3 kV), -40 to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification — confirmed in the datasheet and quotation for your order.
Application fit
SMK-Reeling PUR Salvage Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (DIN VDE 0250-814 / DNV, 0.6/1 kV (1.8/3 kV), -40 to +80 °C, min. bend radius 6 × OD).
Integrated contra-helical aramid anti-torsion braid and high-tear-strength PUR/rubber sheath withstand continuous monospiral and level-win
Engineered per DIN VDE 0250-813/814 and IEC/IEEE 80005-1 for high tensile loads, multi-layer drum coiling and S-bend sheave deflection.
Submersible ether-PUR and marine polychloroprene outer jackets operate in wet deck, splash-zone and shallow-subsea crawler duty.
Resists seawater, hydraulic oil, diesel, UV radiation and severe abrasion across deck rollers and quayside cable trenches.
Heavy drum-reeling cables are optimized for tensile winch coiling rather than tight-radius high-acceleration drag chains.
Use MF-512-PUR Feeder Chain CableConstruction
Shown: SMK-Reeling PUR Salvage Cable (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Single-Mode / Multi-Mode Optical Unit | Hermetic stainless-steel tube / tight-buffered optical unit |
| 2 | Power & Control Copper Conductors | Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation |
| 3 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification with single-mode / multi-mode optical unit and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SMK-Reeling PUR Salvage Cable Construction Schedule (−40…+80 °C) | |||||||
| SMK-Reeling PUR Salvage Cable Hybrid 4G2.5+FO | 4G2.5 mm² Power + 4×SM + 2×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 14.6 | 285 | 18.0 | 90 | |
| SMK-Reeling PUR Salvage Cable Hybrid 4G6+FO | 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | Class 5 SnCu + Aramid Braid + Subsea PUR | 19.2 | 540 | 32.0 | 120 | |
| SMK-Reeling PUR Salvage Cable Hybrid 4G16+FO | 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | Class 5 SnCu + Heavy Aramid + Subsea PUR | 26.5 | 1,120 | 55.0 | 165 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G2.5 mm² Power + 4×SM + 2×2×0.5 | 7.98 | 0.6/1 kV (1.8/3 kV) · 18 kN Tensile | −40…+80 °C |
| 4G6.0 mm² Power + 4×SM/MM + 4×2×0.5 | 3.30 | 0.6/1 kV (1.8/3 kV) · 32 kN Tensile | −40…+80 °C |
| 4G16 mm² Power + 8×SM/MM + 4×2×0.75 | 1.21 | 0.6/1 kV (1.8/3 kV) · 55 kN Tensile | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification) | Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV (1.8/3 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.