Contact
marine winch, salvage, shore power & crawler reeling cableDIN VDE 0250-814 / DNV0.6/1 kV (1.8/3 kV) (-40 to +80 °C)Subsea / Marine Outer Protective She

SMK-Reeling PUR Salvage CableDIN VDE 0250-814 / DNV — 0.6/1 kV (1.8/3 kV) — -40 to +80 °C Subsea & Marine Cable

SMK-Reeling PUR Salvage Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (DIN VDE 0250-814 / DNV, 0.6/1 kV (1.8/3 kV), -40 to +80 °C, min. bend radius 6 × OD).

Water-resistant
Oil-resistant
Outdoor & humid
Approved
Order designation
SMK-Reeling PUR Salvage Cable Hybrid 4G2.5+FO
Outer Ø ≈
14.6 mm
Net weight ≈
285 kg/km
Max. pulling ≈
18.0 kN
Core / stranding
Class 5 SnCu + Aramid Braid + Subsea PUR
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV (1.8/3
Tested per DIN VDE 0250-814 / DNV
Operating temp.
−40…+80 °C
Subsea, deck & cold-water duty
Min. bend radius
6 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Single-Mode / Mu
Hermetic stainless-steel tube / tight-bu
Outer protection
Subsea / Marine
Black hydrolysis- & abrasion-resistant m
Standard
DIN VDE 0250-814
DIN VDE 0250-814 SMK-Reeling PUR Marine

Typical values for this cable type, based on DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is SMK-Reeling PUR Salvage Cable right for your machine?

SMK-Reeling PUR Salvage Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (DIN VDE 0250-814 / DNV, 0.6/1 kV (1.8/3 kV), -40 to +80 °C, min. bend radius 6 × OD).

Motorised monospiral reel

Suitable

Integrated contra-helical aramid anti-torsion braid and high-tear-strength PUR/rubber sheath withstand continuous monospiral and level-win

Cylindrical / multi-layer drum

Suitable

Engineered per DIN VDE 0250-813/814 and IEC/IEEE 80005-1 for high tensile loads, multi-layer drum coiling and S-bend sheave deflection.

Immersion & wet locations

Suitable

Submersible ether-PUR and marine polychloroprene outer jackets operate in wet deck, splash-zone and shallow-subsea crawler duty.

Offshore platform & shipboard deck trays

Suitable

Resists seawater, hydraulic oil, diesel, UV radiation and severe abrasion across deck rollers and quayside cable trenches.

Energy chain / drag chain

Not suitable

Heavy drum-reeling cables are optimized for tensile winch coiling rather than tight-radius high-acceleration drag chains.

Use MF-512-PUR Feeder Chain Cable
Typical machinesCranes & Material HandlingMarine Salvage, Deck Crane & Oceanographic Winch DrumsHigh-Voltage & Low-Voltage Port Shore Power (AMP / HVSC) ReelsSeabed Crawler, Amphibious Excavator & Dredge Reeling SystemsOffshore Aquaculture Feed Barge & Net-Handling Winches

Construction

Layer by layer

Shown: SMK-Reeling PUR Salvage Cable (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (3-layer construction).

SMK-Reeling PUR Salvage Cable — stepped horizontal cutaway showing Single-Mode / Multi-Mode Optical Unit and Subsea /
Layer cutaway
#LayerMaterial & reference
1Single-Mode / Multi-Mode Optical UnitHermetic stainless-steel tube / tight-buffered optical unit
2Power & Control Copper ConductorsStranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation
3Subsea / Marine Outer Protective SheathBlack hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath

SMK-Reeling PUR Salvage Cable — Standard Subsea & Marine Execution

Built to DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification with single-mode / multi-mode optical unit and subsea / marine outer protective sheath

SMK-Reeling PUR Salvage Cable — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

SMK-Reeling PUR Salvage Cable — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
0.6/1 kV (1.8/3 kV) (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification)
Core / conductor construction
Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit
Primary dielectric / optical buffer
Power & Control Copper Conductors — Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation

Thermal

Continuous operating temperature
−40…+80 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+80 °C per DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath
Minimum bending radius
6 × OD
Reinforcement / screen / bedding layer
Power & Control Copper Conductors — Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
SMK-Reeling PUR Salvage Cable
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard SMK-Reeling PUR Salvage Cable configurations

Manufactured to DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
SMK-Reeling PUR Salvage Cable Construction Schedule (−40…+80 °C)
SMK-Reeling PUR Salvage Cable Hybrid 4G2.5+FO4G2.5 mm² Power + 4×SM + 2×2×0.5Class 5 SnCu + Aramid Braid + Subsea PUR14.628518.090
SMK-Reeling PUR Salvage Cable Hybrid 4G6+FO4G6.0 mm² Power + 4×SM/MM + 4×2×0.5Class 5 SnCu + Aramid Braid + Subsea PUR19.254032.0120
SMK-Reeling PUR Salvage Cable Hybrid 4G16+FO4G16 mm² Power + 8×SM/MM + 4×2×0.75Class 5 SnCu + Heavy Aramid + Subsea PUR26.51,12055.0165
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification)DC resistance at 20 °C, optical attenuation and wall thickness within DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification)Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV (1.8/3 kV) ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250-814 / DNV CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SMK-Reeling PUR Salvage Cable DIN VDE 0250-814 / DNV 0.6/1 kV (1.8/3 kV) CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define SMK-Reeling PUR Salvage Cable (SMK-Reeling PUR Salvage Cable)?
SMK-Reeling PUR Salvage Cable (SMK-Reeling PUR Salvage Cable) is manufactured in accordance with DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification for 0.6/1 kV (1.8/3 kV) subsea,ROV and marine aquaculture service over -40 to +80 °C. Its 3-layer construction comprises single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for SMK-Reeling PUR Salvage Cable?
The minimum bending radius for SMK-Reeling PUR Salvage Cable is 6 × OD across its continuous operating temperature range of -40 to +80 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of SMK-Reeling PUR Salvage Cable arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit; (02) Power & Control Copper Conductors — Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation; (03) Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath.
What factory test certificates are supplied with SMK-Reeling PUR Salvage Cable?
Every production drum of SMK-Reeling PUR Salvage Cable undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per DIN VDE 0250-814 SMK-Reeling PUR Marine Salvage Winch Reeling Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for SMK-Reeling PUR Salvage Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SMK-Reeling PUR Salvage Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 