Energy chain / drag chain
Short-pitch Class 6 copper stranding and low-adhesion TPE/PUR jackets deliver multi-million-cycle life in horizontal and self-supporting d
Product
MF-512-PUR Flexible Feeder Cable featuring flexible stranded copper conductors (12 cores) and subsea / marine outer protective sheath (DIN VDE 0285 / UL 20233, 300/500 V, -40 to +80 °C, min. bend radius 5 × OD).
Typical values for this cable type, based on DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard — confirmed in the datasheet and quotation for your order.
Application fit
MF-512-PUR Flexible Feeder Cable featuring flexible stranded copper conductors (12 cores) and subsea / marine outer protective sheath (DIN VDE 0285 / UL 20233, 300/500 V, -40 to +80 °C, min. bend radius 5 × OD).
Short-pitch Class 6 copper stranding and low-adhesion TPE/PUR jackets deliver multi-million-cycle life in horizontal and self-supporting d
Robotic torsion (RF-Torsion) and coiled spiral builds absorb ±180°/m to ±360°/m multi-axis twist on ROV pan-and-tilt and manipulator wrist
Hydrolysis-, seawater-, fish-oil- and UV-resistant outer jackets operate reliably above open fish tanks and coastal feed tracks.
High-coverage tinned copper braided screens protect encoder, load-cell and servo signals from VFD interference.
Drag-chain and robotic wrist cables are not designed for high-tension deep-ocean vertical lift winches.
Use RM0045 Heavy ROV UmbilicalConstruction
Shown: MF-512-PUR Flexible Feeder (DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard) featuring flexible stranded copper conductors (12 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (12 | Class 5 / class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | High-stiffness polypropylene (pp) core insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard with flexible stranded copper conductors (12 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MF-512-PUR Flexible Feeder Construction Schedule (−40…+80 °C) | |||||||
| MF-512-PUR Flexible Feeder 4G1.5 / 5C18AWG | 4G1.5 mm² (or 5C × 18 AWG) | IEC 60228 Class 5/6 Cu/SnCu | 9.6 | 145 | 2.2 | 55 | |
| MF-512-PUR Flexible Feeder 7G1.5 / 8C16AWG | 7G1.5 mm² (or 8C × 16 AWG) | IEC 60228 Class 5/6 Cu/SnCu | 12.2 | 235 | 3.6 | 70 | |
| MF-512-PUR Flexible Feeder 12G2.5 / 16C16AWG | 12G2.5 mm² (or 16C × 16 AWG) | IEC 60228 Class 5/6 Cu/SnCu | 17.4 | 510 | 7.5 | 105 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G1.5 mm² (or 5C × 18 AWG) | 13.30 | 300/500 V (18 A) | −40…+80 °C |
| 7G1.5 mm² (or 8C × 16 AWG) | 13.30 | 300/500 V (16 A) | −40…+80 °C |
| 12G2.5 mm² (or 16C × 16 AWG) | 7.98 | 300/500 V (22 A) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard) | Zero dielectric breakdown and verified wet insulation resistance for 300/500 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (DIN VDE 0285 MF-512-PUR Flexible Aquaculture Feeder Drag-Chain Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.